These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 39196737)
61. Long term study of motivational and cognitive effects of low-intensity focused ultrasound neuromodulation in the dorsal striatum of nonhuman primates. Munoz F; Meaney A; Gross A; Liu K; Pouliopoulos AN; Liu D; Konofagou EE; Ferrera VP Brain Stimul; 2022; 15(2):360-372. PubMed ID: 35092823 [TBL] [Abstract][Full Text] [Related]
63. Submicron-bubble-enhanced focused ultrasound for blood-brain barrier disruption and improved CNS drug delivery. Fan CH; Liu HL; Ting CY; Lee YH; Huang CY; Ma YJ; Wei KC; Yen TC; Yeh CK PLoS One; 2014; 9(5):e96327. PubMed ID: 24788566 [TBL] [Abstract][Full Text] [Related]
64. Transcranial Theranostic Ultrasound for Pre-Planning and Blood-Brain Barrier Opening: A Feasibility Study Using an Imaging Phased Array In Vitro and In Vivo. Batts A; Ji R; Kline-Schoder A; Noel R; Konofagou E IEEE Trans Biomed Eng; 2022 Apr; 69(4):1481-1490. PubMed ID: 34665716 [TBL] [Abstract][Full Text] [Related]
65. Vasculotide restores the blood-brain barrier after focused ultrasound-induced permeability in a mouse model of Alzheimer's disease. Lynch M; Heinen S; Markham-Coultes K; O'Reilly M; Van Slyke P; Dumont DJ; Hynynen K; Aubert I Int J Med Sci; 2021; 18(2):482-493. PubMed ID: 33390817 [TBL] [Abstract][Full Text] [Related]
66. In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice. Tung YS; Vlachos F; Choi JJ; Deffieux T; Selert K; Konofagou EE Phys Med Biol; 2010 Oct; 55(20):6141-55. PubMed ID: 20876972 [TBL] [Abstract][Full Text] [Related]
67. MR-guided blood-brain barrier opening induced by rapid short-pulse ultrasound in non-human primates. Zhou H; Liu Y; Long X; Qiao Y; Lee J; Liu X; Zheng H; Zou C Quant Imaging Med Surg; 2021 Jun; 11(6):2415-2427. PubMed ID: 34079712 [TBL] [Abstract][Full Text] [Related]
68. Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: a short-term study. Baseri B; Choi JJ; Tung YS; Konofagou EE Ultrasound Med Biol; 2010 Sep; 36(9):1445-59. PubMed ID: 20800172 [TBL] [Abstract][Full Text] [Related]
69. Acute Inflammatory Response Following Increased Blood-Brain Barrier Permeability Induced by Focused Ultrasound is Dependent on Microbubble Dose. McMahon D; Hynynen K Theranostics; 2017; 7(16):3989-4000. PubMed ID: 29109793 [No Abstract] [Full Text] [Related]
70. Blood-Brain Barrier Closure Time After Controlled Ultrasound-Induced Opening Is Independent of Opening Volume. O'Reilly MA; Hough O; Hynynen K J Ultrasound Med; 2017 Mar; 36(3):475-483. PubMed ID: 28108988 [TBL] [Abstract][Full Text] [Related]
71. Magnetic-resonance imaging for kinetic analysis of permeability changes during focused ultrasound-induced blood-brain barrier opening and brain drug delivery. Chai WY; Chu PC; Tsai MY; Lin YC; Wang JJ; Wei KC; Wai YY; Liu HL J Control Release; 2014 Oct; 192():1-9. PubMed ID: 24969355 [TBL] [Abstract][Full Text] [Related]
72. Targeted opening of the blood-brain barrier using VCAM-1 functionalised microbubbles and "whole brain" ultrasound. Johanssen VA; Ruan JL; Vince O; Thomas A; Peeters S; Soto MS; Buck J; Gray M; Stride E; Sibson NR Theranostics; 2024; 14(10):4076-4089. PubMed ID: 38994029 [TBL] [Abstract][Full Text] [Related]
73. On the accuracy of optically tracked transducers for image-guided transcranial ultrasound. Chaplin V; Phipps MA; Jonathan SV; Grissom WA; Yang PF; Chen LM; Caskey CF Int J Comput Assist Radiol Surg; 2019 Aug; 14(8):1317-1327. PubMed ID: 31069643 [TBL] [Abstract][Full Text] [Related]
74. Ultrasound-mediated blood-brain barrier opening uncovers an intracerebral perivenous fluid network in persons with Alzheimer's disease. Mehta RI; Carpenter JS; Mehta RI; Haut MW; Wang P; Ranjan M; Najib U; D'Haese PF; Rezai AR Fluids Barriers CNS; 2023 Jun; 20(1):46. PubMed ID: 37328855 [TBL] [Abstract][Full Text] [Related]
75. Cavitation-enhanced nonthermal ablation in deep brain targets: feasibility in a large animal model. Arvanitis CD; Vykhodtseva N; Jolesz F; Livingstone M; McDannold N J Neurosurg; 2016 May; 124(5):1450-9. PubMed ID: 26381252 [TBL] [Abstract][Full Text] [Related]
76. Neuronavigation-guided focused ultrasound (NaviFUS) for transcranial blood-brain barrier opening in recurrent glioblastoma patients: clinical trial protocol. Chen KT; Lin YJ; Chai WY; Lin CJ; Chen PY; Huang CY; Kuo JS; Liu HL; Wei KC Ann Transl Med; 2020 Jun; 8(11):673. PubMed ID: 32617293 [TBL] [Abstract][Full Text] [Related]
77. Blood-brain barrier opening in a large animal model using closed-loop microbubble cavitation-based feedback control of focused ultrasound sonication. Chien CY; Xu L; Pacia CP; Yue Y; Chen H Sci Rep; 2022 Sep; 12(1):16147. PubMed ID: 36167747 [TBL] [Abstract][Full Text] [Related]
78. Image-Guided Focused-Ultrasound CNS Molecular Delivery: An Implementation via Dynamic Contrast-Enhanced Magnetic-Resonance Imaging. Chai WY; Chu PC; Tsai CH; Lin CY; Yang HW; Lai HY; Liu HL Sci Rep; 2018 Mar; 8(1):4151. PubMed ID: 29515222 [TBL] [Abstract][Full Text] [Related]
79. CMUT as a Transmitter for Microbubble-Assisted Blood-Brain Barrier Opening. Kilinc MS; Pakdaman Zangabad R; Arvanitis C; Levent Degertekin F IEEE Trans Ultrason Ferroelectr Freq Control; 2024 Aug; 71(8):1042-1050. PubMed ID: 38905098 [TBL] [Abstract][Full Text] [Related]
80. Enhancement in blood-tumor barrier permeability and delivery of liposomal doxorubicin using focused ultrasound and microbubbles: evaluation during tumor progression in a rat glioma model. Aryal M; Park J; Vykhodtseva N; Zhang YZ; McDannold N Phys Med Biol; 2015 Mar; 60(6):2511-27. PubMed ID: 25746014 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]