These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
135 related articles for article (PubMed ID: 39198487)
21. The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development. Telyshev D; Denisov M; Pugovkin A; Selishchev S; Nesterenko I Artif Organs; 2018 Apr; 42(4):432-443. PubMed ID: 29508416 [TBL] [Abstract][Full Text] [Related]
22. Numerical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance. Untaroiu A; Throckmorton AL; Patel SM; Wood HG; Allaire PE; Olsen DB Artif Organs; 2005 Jul; 29(7):581-91. PubMed ID: 15982287 [TBL] [Abstract][Full Text] [Related]
23. Effects of Cone-Shaped Bend Inlet Cannulas of an Axial Blood Pump on Thrombus Formation: An Experiment and Simulation Study. Liu G; Zhou J; Sun H; Zhang Y; Chen H; Hu S Med Sci Monit; 2017 Apr; 23():1655-1661. PubMed ID: 28379938 [TBL] [Abstract][Full Text] [Related]
24. In vitro and in vivo characterization of three different modes of pump operation when using a left ventricular assist device as a right ventricular assist device. Stevens MC; Gregory SD; Nestler F; Thomson B; Choudhary J; Garlick B; Pauls JP; Fraser JF; Timms D Artif Organs; 2014 Nov; 38(11):931-9. PubMed ID: 24660783 [TBL] [Abstract][Full Text] [Related]
25. Fluid Dynamic Study of the Penn State Pediatric Total Artificial Heart. Kubicki C; Raich E; Selinsky P; Ponnaluri S; Weiss WJ; Manning KB J Biomech Eng; 2024 Oct; 146(10):. PubMed ID: 38652582 [TBL] [Abstract][Full Text] [Related]
26. PIV measurements of flow in a centrifugal blood pump: time-varying flow. Day SW; McDaniel JC J Biomech Eng; 2005 Apr; 127(2):254-63. PubMed ID: 15971703 [TBL] [Abstract][Full Text] [Related]
27. Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD. Chen Z; Jena SK; Giridharan GA; Sobieski MA; Koenig SC; Slaughter MS; Griffith BP; Wu ZJ Med Biol Eng Comput; 2019 Apr; 57(4):807-818. PubMed ID: 30406881 [TBL] [Abstract][Full Text] [Related]
28. Comparing the performances of circular ponds with different impellers by CFD simulation and microalgae culture experiments. Meng C; Huang J; Ye C; Cheng W; Chen J; Li Y Bioprocess Biosyst Eng; 2015 Jul; 38(7):1347-63. PubMed ID: 25680396 [TBL] [Abstract][Full Text] [Related]
29. Computational Fluid Dynamics (CFD) study of the 4th generation prototype of a continuous flow Ventricular Assist Device (VAD). Song X; Wood HG; Olsen D J Biomech Eng; 2004 Apr; 126(2):180-7. PubMed ID: 15179847 [TBL] [Abstract][Full Text] [Related]
30. Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device. Wu J; Paden BE; Borovetz HS; Antaki JF Artif Organs; 2010 May; 34(5):402-11. PubMed ID: 19832736 [TBL] [Abstract][Full Text] [Related]
31. [Design of an axial blood pump of diffuser with splitter blades and cantilevered main blades]. Liu G; Xi J; Chen H; Zhang Y; Hou J; Zhou J; Sun H; Hu S Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2019 Jun; 36(3):379-385. PubMed ID: 31232539 [TBL] [Abstract][Full Text] [Related]
32. Assessment of right pump outflow banding and speed changes on pulmonary hemodynamics during biventricular support with two rotary left ventricular assist devices. Timms D; Gude E; Gaddum N; Lim E; Greatrex N; Wong K; Steinseifer U; Lovell N; Fraser J; Fiane A Artif Organs; 2011 Aug; 35(8):807-13. PubMed ID: 21726243 [TBL] [Abstract][Full Text] [Related]
33. Multi-indicator analysis of mechanical blood damage with five clinical ventricular assist devices. Li Y; Wang H; Xi Y; Sun A; Deng X; Chen Z; Fan Y Comput Biol Med; 2022 Dec; 151(Pt A):106271. PubMed ID: 36347061 [TBL] [Abstract][Full Text] [Related]
34. Numerical study of a centrifugal blood pump with different impeller profiles. Song G; Chua LP; Lim TM ASAIO J; 2010; 56(1):24-9. PubMed ID: 20019595 [TBL] [Abstract][Full Text] [Related]
35. Visualization study of the transient flow in the centrifugal blood pump impeller. Tsukiya T; Taenaka Y; Tatsumi E; Takano H ASAIO J; 2002; 48(4):431-6. PubMed ID: 12141476 [TBL] [Abstract][Full Text] [Related]
36. Ex vivo assessment of erythrocyte tolerance to the HeartWare ventricular assist device operated in three discrete configurations. Kuck L; Simmonds MJ; Chan CHH; Pauls JP; Tansley GD; Feldmann F; McNamee AP Artif Organs; 2021 Jun; 45(6):E146-E157. PubMed ID: 33236358 [TBL] [Abstract][Full Text] [Related]
37. Experimental and Numerical Investigation of an Axial Rotary Blood Pump. Schüle CY; Thamsen B; Blümel B; Lommel M; Karakaya T; Paschereit CO; Affeld K; Kertzscher U Artif Organs; 2016 Nov; 40(11):E192-E202. PubMed ID: 27087467 [TBL] [Abstract][Full Text] [Related]
38. Time-Resolved Particle Image Velocimetry Measurements with Wall Shear Stress and Uncertainty Quantification for the FDA Nozzle Model. Raben JS; Hariharan P; Robinson R; Malinauskas R; Vlachos PP Cardiovasc Eng Technol; 2016 Mar; 7(1):7-22. PubMed ID: 26628081 [TBL] [Abstract][Full Text] [Related]
39. Development of Inspired Therapeutics Pediatric VAD: Computational Analysis and Characterization of VAD V3. Tompkins LH; Gellman BN; Prina SR; Morello GF; Roussel T; Kopechek JA; Williams SJ; Petit PC; Slaughter MS; Koenig SC; Dasse KA Cardiovasc Eng Technol; 2022 Aug; 13(4):624-637. PubMed ID: 35013917 [TBL] [Abstract][Full Text] [Related]
40. Evaluation of hydraulic radial forces on the impeller by the volute in a centrifugal rotary blood pump. Boehning F; Timms DL; Amaral F; Oliveira L; Graefe R; Hsu PL; Schmitz-Rode T; Steinseifer U Artif Organs; 2011 Aug; 35(8):818-25. PubMed ID: 21843297 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]