These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 3920172)

  • 1. Radiation transmission and scattering for medical linacs producing x rays of 6 and 15 MV: comparison of calculations with measurements.
    Numark NJ; Kase KR
    Health Phys; 1985 Mar; 48(3):289-95. PubMed ID: 3920172
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Be aware of neutrons outside short mazes from 10-MV linear accelerators X-rays in radiotherapy facilities.
    Brockstedt S; Holstein H; Jakobsson L; Tomaszewicz A; Knöös T
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):464-7. PubMed ID: 25802465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-614. PubMed ID: 28102603
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The measurement of photoneutron dose in the vicinity of clinical linear accelerators.
    Rivera JC; Falcão RC; Dealmeida CE
    Radiat Prot Dosimetry; 2008; 130(4):403-9. PubMed ID: 18375468
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neutron contamination of 10 MV X-rays: its relevance to treatment room door and maze design.
    Rudd PJ; Prior D; Austin-Smith S
    Br J Radiol; 2007 Jun; 80(954):469-75. PubMed ID: 17360932
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neutrons from high-energy x-ray medical accelerators: an estimate of risk to the radiotherapy patient.
    Nath R; Epp ER; Laughlin JS; Swanson WP; Bond VP
    Med Phys; 1984; 11(3):231-41. PubMed ID: 6429495
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-14. PubMed ID: 25771559
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bremsstrahlung and photoneutron production in a steel shield for 15-22-MeV clinical electron beams.
    Fujita Y; Myojoyama A; Saitoh H
    Radiat Prot Dosimetry; 2015 Feb; 163(2):148-59. PubMed ID: 24821930
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation protection aspects of a new high-energy linear accelerator.
    O'Brien P; Michaels HB; Gillies B; Aldrich JE; Andrew JW
    Med Phys; 1985; 12(1):101-7. PubMed ID: 3919249
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
    Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
    Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Attenuation of primary and scatter radiation in concrete and steel for 18 MV X-rays from a Clinac-20 linear accelerator.
    Abrath FG; Bello J; Purdy JA
    Health Phys; 1983 Nov; 45(5):969-73. PubMed ID: 6417056
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Neutron scattering in concrete and wood: Part II--Oblique incidence.
    Facure A; Silva AX; Rivera JC; Falcão RC
    Radiat Prot Dosimetry; 2008; 128(3):367-74. PubMed ID: 17673488
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Air kerma transmission factors of Scattered X-rays in the maze of a Linac room for lead shield].
    Kato H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Jan; 61(1):96-103. PubMed ID: 15682037
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characteristics of the photoneutron contamination present in a high-energy radiotherapy treatment room.
    Garnica-Garza HM
    Phys Med Biol; 2005 Feb; 50(3):531-9. PubMed ID: 15773728
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Photoneutron contamination from an 18 MV Saturne medical linear accelerator in the treatment room.
    Khosravi M; Shahbazi-Gahrouei D; Jabbari K; Nasri-Nasrabadi M; Baradaran-Ghahfarokhi M; Siavashpour Z; Gheisari R; Amiri B
    Radiat Prot Dosimetry; 2013 Sep; 156(3):356-63. PubMed ID: 23538892
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The neutron dose and energy spectrum outside a 20-MV accelerator treatment room.
    Muller-Runkel R; Ovadia J; Culbert H; Cooke RH; Dolecek EH
    Med Phys; 1986; 13(5):742-7. PubMed ID: 3097465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Scattered fractions of dose from 6,10,18, and 25 MV linear accelerator x rays in radiotherapy facilities.
    Shobe J; Rodgers JE; Taylor PL
    Health Phys; 1999 Jan; 76(1):27-35. PubMed ID: 9883944
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
    Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
    Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.