These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 39217026)

  • 1. Investigation Into the Subharmonic Response of Three Contrast Agents in Static and Dynamic Flow Environments Using a Commercially Available Diagnostic Ultrasound Scanner.
    Mayer H; Kim GW; Machado P; Eisenbrey JR; Vu T; Wallace K; Forsberg F
    Ultrasound Med Biol; 2024 Nov; 50(11):1731-1738. PubMed ID: 39217026
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner.
    Eisenbrey JR; Dave JK; Halldorsdottir VG; Merton DA; Machado P; Liu JB; Miller C; Gonzalez JM; Park S; Dianis S; Chalek CL; Thomenius KE; Brown DB; Navarro V; Forsberg F
    Ultrasonics; 2011 Dec; 51(8):890-7. PubMed ID: 21621239
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.
    Halldorsdottir VG; Dave JK; Leodore LM; Eisenbrey JR; Park S; Hall AL; Thomenius K; Forsberg F
    Ultrason Imaging; 2011 Jul; 33(3):153-64. PubMed ID: 21842580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation.
    Dave JK; Halldorsdottir VG; Eisenbrey JR; Merton DA; Liu JB; Machado P; Zhao H; Park S; Dianis S; Chalek CL; Thomenius KE; Brown DB; Forsberg F
    Ultrasonics; 2013 Apr; 53(4):880-8. PubMed ID: 23347593
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-Dimensional Subharmonic Aided Pressure Estimation for Assessing Arterial Plaques in a Rabbit Model.
    Nam K; Liu JB; Eisenbrey JR; Stanczak M; Machado P; Li J; Li Z; Wei Y; Forsberg F
    J Ultrasound Med; 2019 Jul; 38(7):1865-1873. PubMed ID: 30560581
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Comparative Study of Commercially Available Ultrasound Contrast Agents for Sub-harmonic-Aided Pressure Estimation (SHAPE) in a Bladder Phantom.
    Kalayeh K; Fowlkes JB; Yeras S; Chen A; Daignault-Newton S; Schultz WW; Sack BS
    Ultrasound Med Biol; 2024 Oct; 50(10):1494-1505. PubMed ID: 39054243
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo.
    Gupta I; Eisenbrey J; Stanczak M; Sridharan A; Dave JK; Liu JB; Hazard C; Wang X; Wang P; Li H; Wallace K; Forsberg F
    J Ultrasound Med; 2017 Jan; 36(1):3-11. PubMed ID: 27943411
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characteristics and Echogenicity of Clinical Ultrasound Contrast Agents: An In Vitro and In Vivo Comparison Study.
    Hyvelin JM; Gaud E; Costa M; Helbert A; Bussat P; Bettinger T; Frinking P
    J Ultrasound Med; 2017 May; 36(5):941-953. PubMed ID: 28240842
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring.
    Dave JK; Halldorsdottir VG; Eisenbrey JR; Merton DA; Liu JB; Zhou JH; Wang HK; Park S; Dianis S; Chalek CL; Lin F; Thomenius KE; Brown DB; Forsberg F
    Ultrasound Med Biol; 2012 Oct; 38(10):1784-98. PubMed ID: 22920550
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On Factors Affecting Subharmonic-aided Pressure Estimation (SHAPE).
    Gupta I; Eisenbrey JR; Machado P; Stanczak M; Wallace K; Forsberg F
    Ultrason Imaging; 2019 Jan; 41(1):35-48. PubMed ID: 30417745
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals.
    Esposito C; Tzan K; Machado P; Forsberg F; Dave JK
    Ultrason Imaging; 2024 Mar; 46(2):130-134. PubMed ID: 38318708
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimal Control of SonoVue Microbubbles to Estimate Hydrostatic Pressure.
    Nio AQX; Faraci A; Christensen-Jeffries K; Raymond JL; Monaghan MJ; Fuster D; Forsberg F; Eckersley RJ; Lamata P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Mar; 67(3):557-567. PubMed ID: 31634833
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept.
    Halldorsdottir VG; Dave JK; Eisenbrey JR; Machado P; Zhao H; Liu JB; Merton DA; Forsberg F
    Ultrasonics; 2014 Sep; 54(7):1938-44. PubMed ID: 24856899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noninvasive Pressure Estimation Based on the Subharmonic Response of SonoVue: Application to Intracranial Blood Pressure Assessment.
    Qiao X; Wen Y; Yu J; Bouakaz A; Zong Y; Wan M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Mar; 69(3):957-966. PubMed ID: 34941508
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of Needle and Catheter Size on Commercially Available Ultrasound Contrast Agents.
    Eisenbrey JR; Daecher A; Kramer MR; Forsberg F
    J Ultrasound Med; 2015 Nov; 34(11):1961-8. PubMed ID: 26384606
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Processing of subharmonic signals from ultrasound contrast agents to determine ambient pressures.
    Dave JK; Halldorsdottir VG; Eisenbrey JR; Forsberg F
    Ultrason Imaging; 2012 Apr; 34(2):81-92. PubMed ID: 22724314
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Subharmonic Scattering of SonoVue Microbubbles Within 10-40-mmHg Overpressures In Vitro.
    Xu G; Lu H; Yang H; Li D; Liu R; Su M; Jin B; Li C; Lv T; Du S; Yang J; Qiu W; Mao Y; Li F
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Dec; 68(12):3583-3591. PubMed ID: 34329162
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.
    Sridharan A; Eisenbrey JR; Liu JB; Machado P; Halldorsdottir VG; Dave JK; Zhao H; He Y; Park S; Dianis S; Wallace K; Thomenius KE; Forsberg F
    Invest Radiol; 2013 Sep; 48(9):654-60. PubMed ID: 23695085
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correlation Between Portal Vein Pressure and Subharmonic Scattering Signals From SonoVue Microbubbles in Canines.
    Lu H; Xu G; Wang Y; Yang H; Li D; Huang L; Su M; Li C; Qiu W; Mao Y; Yu W; Li F
    Ultrasound Med Biol; 2023 Jan; 49(1):203-211. PubMed ID: 36266141
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hepatic Vein Contrast-Enhanced Ultrasound Subharmonic Imaging Signal as a Screening Test for Portal Hypertension.
    Machado P; Gupta I; Gummadi S; Stanczak M; Wessner CE; Fenkel JM; Shaw CM; Shamini-Noori S; Schultz S; Soulen MC; Sehgal CM; Wallace K; Eisenbrey JR; Forsberg F
    Dig Dis Sci; 2021 Dec; 66(12):4354-4360. PubMed ID: 33392869
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.