These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 39219587)

  • 1. Evaluation of X-ray protective goggles in mitigating eye lens radiation exposure during radiopharmaceutical handling and patient care in nuclear medicine.
    Oikawa T; Saito K; Kurihara K; Horikawa D; Uruno K; Kajiwara H; Ohashi S; Hotta M; Yagi N; Kitamura H; Hasegawa S; Minamimoto R
    Glob Health Med; 2024 Aug; 6(4):244-250. PubMed ID: 39219587
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Estimation of Eye Lens Dose during the Handling of Radiopharmaceuticals and Using X-ray Protective Goggles for Dose Reduction in Nuclear Medicine].
    Matsutomo N; Fukami M; Koike T; Yamamoto T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2022 Apr; 78(4):348-356. PubMed ID: 35264549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of radiation protection means on the dose to the lens of the eye while handling radionuclides in nuclear medicine.
    Bruchmann I; Szermerski B; Behrens R; Geworski L
    Z Med Phys; 2016 Dec; 26(4):298-303. PubMed ID: 26341280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring and Protection against Radiation Dose to Eyes of Operators Performing Neuroendovascular Procedures: A Nationwide Study in Japan.
    Sakamoto H; Moritake T; Sun L; Kobayashi I; Kawauchi S; Abe T; Tsukamoto A; Morimoto Y; Daida H; Matsumaru Y
    J Neuroendovasc Ther; 2022; 16(7):354-360. PubMed ID: 37502341
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radioprotection of eye lens using protective material in neuro cone-beam computed tomography: Estimation of dose reduction rate and image quality.
    Kawauchi S; Chida K; Moritake T; Hamada Y; Tsuruta W
    Phys Med; 2021 Feb; 82():192-199. PubMed ID: 33647602
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Design and Test of Automatic Dispensing and Injecting System for Positron Radiopharmaceuticals].
    Guo N; Wang T; Huo L; Li F; Liu LJ; Li Y; Ba JT
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2021 Jun; 43(3):429-434. PubMed ID: 34238420
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Measurement of the Lens Dose for Radiological Technologists during Mobile Radiography].
    Matsumoto H; Takei Y; Matsuda E; Masuda T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2023 Jan; 79(1):38-45. PubMed ID: 36418072
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Annual Staff Doses and Radiation Shielding Efficiencies of Thyroid Shield and Lead Apron during Preparation and Administration of
    Khalili N; Zakariaee SS; Gharebaghi EJ; Salehi Y; Changizi V
    J Med Signals Sens; 2022; 12(1):90-94. PubMed ID: 35265471
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The Method for Estimation of Radiation Dose of Eye Lens Covered by Radiation Protection Glasses Using Personal Dosimeter for Trunk of the Body and X-ray Shielding Material].
    Osanai M; Sato K; Sato H; Kudo K; Hosokawa S; Fujita A; Kitajima M; Tsushima M; Komiya N; Kudo M; Saito Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2021; 77(12):1432-1443. PubMed ID: 34924480
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of a reliable assessment for occupational eye lens dose in nuclear medicine.
    Miyaji N; Miwa K; Iimori T; Wagatsuma K; Tsushima H; Yokotsuka N; Murata T; Kasahara T; Terauchi T
    J Appl Clin Med Phys; 2022 Aug; 23(8):e13713. PubMed ID: 35775691
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Addressing the efficiency of X-ray protective eyewear: Proposal for the introduction of a new comprehensive parameter, the Eye Protection Effectiveness (EPE).
    Doria S; Fedeli L; Redapi L; Piffer S; Rossi F; Falivene A; Busoni S; Belli G; Gori C; Taddeucci A
    Phys Med; 2020 Feb; 70():216-223. PubMed ID: 32062466
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effectiveness of a free-standing lead-shield in reducing spine surgeon radiation exposure during intraoperative 3-dimensional imaging.
    Guenthner G; Eddy A; Sembrano J; Polly DW; Martin CT
    Spine J; 2020 Oct; 20(10):1685-1691. PubMed ID: 32445800
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New organ-based tube current modulation method to reduce the radiation dose during computed tomography of the head: evaluation of image quality and radiation dose to the eyes in the phantom study.
    Kim JS; Kwon SM; Kim JM; Yoon SW
    Radiol Med; 2017 Aug; 122(8):601-608. PubMed ID: 28341967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Eye lens dose for medical staff assisting patients during computed tomography: comparison of several types of radioprotective glasses.
    Fukushima K; Matsubara K; Tanabe M; Ito H
    J Radiol Prot; 2023 Apr; 43(2):. PubMed ID: 37023744
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of backscatter radiation on the occupational eye-lens dose.
    Ohno S; Konta S; Shindo R; Yamamoto K; Isobe R; Inaba Y; Suzuki M; Zuguchi M; Chida K
    J Radiat Res; 2024 Jul; 65(4):450-458. PubMed ID: 38818635
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The Need for Lens Radiation Protection for Healthcare Provider in Open and Internal Fixation of the Hip Joint].
    Matsumoto H; Tokushige S; Takei Y; Uyama Y; Mura M; Hitomi G
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2024 Mar; 80(3):287-295. PubMed ID: 38296460
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Occupational eye lens dose in endoscopic retrograde cholangiopancreatography using a dedicated eye lens dosimeter.
    Imai S; Akahane M; Ogata Y; Tanki N; Sato H; Tameike K
    J Radiol Prot; 2021 Aug; 41(3):. PubMed ID: 34102616
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Usefulness of a lead-acrylic shield for reducing lens dose of assistant in x-ray CT examination.
    Ito H; Matsubara K; Kobayashi I; Sakai T; Isobe T; Yanagawa N; Ochi S
    J Radiol Prot; 2022 Jun; 42(2):. PubMed ID: 35705067
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Eye lens dose correlations with personal dose equivalent and patient exposure in paediatric interventional cardiology performed with a fluoroscopic biplane system.
    Alejo L; Koren C; Corredoira E; Sánchez F; Bayón J; Serrada A; Guibelalde E
    Phys Med; 2017 Apr; 36():81-90. PubMed ID: 28410690
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction.
    Raissaki M; Perisinakis K; Damilakis J; Gourtsoyiannis N
    Pediatr Radiol; 2010 Nov; 40(11):1748-54. PubMed ID: 20552187
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.