These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 39281533)
1. Experimental study on the impact of indoor unit airflow velocity on the performance of an automotive heat pump system with a suction line heat exchanger. Alkan A Heliyon; 2024 Sep; 10(17):e36719. PubMed ID: 39281533 [TBL] [Abstract][Full Text] [Related]
2. Performance Characteristics of Automobile Air Conditioning Using the R134a/R1234yf Mixture. Shin Y; Kim T; Lee A; Cho H Entropy (Basel); 2019 Dec; 22(1):. PubMed ID: 33285779 [TBL] [Abstract][Full Text] [Related]
3. Experimental investigation on combustion characteristics of flammable refrigerant R290/R1234yf leakage from heat pump system for electric vehicles. Li K; Wang J; Luo S; Wang Z; Zhou X; Fang J; Su L; Tu R R Soc Open Sci; 2020 Apr; 7(4):191478. PubMed ID: 32431863 [TBL] [Abstract][Full Text] [Related]
4. Horizontal convective boiling of R1234yf, R134a, and R450A within a micro-fin tube. Kedzierski MA; Kang D Int J Refrig; 2018; 88():. PubMed ID: 30983648 [TBL] [Abstract][Full Text] [Related]
5. Molecular Simulations of Adsorption and Energy Storage of R1234yf, R1234ze(z), R134a, R32, and their Mixtures in M-MOF-74 (M = Mg, Ni) Nanoparticles. Cai S; Tian S; Lu Y; Wang G; Pu Y; Peng K Sci Rep; 2020 Apr; 10(1):7265. PubMed ID: 32350321 [TBL] [Abstract][Full Text] [Related]
6. Research on the Application of an HFO1234yf/HFC134a Mixture in a Vehicle Air-Conditioner System with an Internal Heat Exchanger. Meng Z; Cui X; Liu Y; Hu R; Wang S; Du C ACS Omega; 2022 Sep; 7(37):33138-33146. PubMed ID: 36157783 [TBL] [Abstract][Full Text] [Related]
7. Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a. Li S; Liu Y; Liu Y; Zhang J Environ Sci Pollut Res Int; 2021 Oct; 28(40):57166-57182. PubMed ID: 34089158 [TBL] [Abstract][Full Text] [Related]
8. A Theoretical Comparative Study of Vapor-Compression Refrigeration Cycle using Al Li S; Lu J Entropy (Basel); 2022 Dec; 24(12):. PubMed ID: 36554225 [TBL] [Abstract][Full Text] [Related]
9. Thermal Energy Storage of R1234yf, R1234ze, R134a and R32/MOF-74 Nanofluids: A Molecular Simulation Study. Hu J; Liu C; Liu L; Li Q Materials (Basel); 2018 Jul; 11(7):. PubMed ID: 29986542 [TBL] [Abstract][Full Text] [Related]
10. Pool Boiling of Low-GWP Replacements for R134a on a Reentrant Cavity Surface. Kedzierski MA; Lin L; Kang D J Heat Transfer; 2018; 140():. PubMed ID: 31274925 [TBL] [Abstract][Full Text] [Related]
11. Energo- and exergo-technical assessment of ground-source heat pump systems for geothermal energy production from underground mines. Amiri L; Madadian E; Hassani FP Environ Technol; 2019 Nov; 40(27):3534-3546. PubMed ID: 29806558 [TBL] [Abstract][Full Text] [Related]
12. Annual Performance of a Two-Speed, Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility. Payne WV ASHRAE Winter Conf Pap; 2016 Jan; 2016(Winter Conference):. PubMed ID: 28729740 [TBL] [Abstract][Full Text] [Related]
13. Performance of Introducing Outdoor Cold Air for Cooling a Plant Production System with Artificial Light. Wang J; Tong Y; Yang Q; Xin M Front Plant Sci; 2016; 7():270. PubMed ID: 27066012 [TBL] [Abstract][Full Text] [Related]
14. Field monitoring data on a residential exhaust air heat pump system (air-to-air heat pump). Shirani A; Merzkirch A; Roesler J; Leyer S; Scholzen F; Maas S Data Brief; 2021 Oct; 38():107386. PubMed ID: 34604479 [TBL] [Abstract][Full Text] [Related]
15. Fouling of Polymeric Hollow Fiber Heat Exchangers by Air Dust. Astrouski I; Raudensky M; Kudelova T; Kroulikova T Materials (Basel); 2020 Nov; 13(21):. PubMed ID: 33147833 [TBL] [Abstract][Full Text] [Related]
16. Identifying the performance and losses of a scroll compressor with vapour injection and R1234ze(E). Meramveliotakis G; Kosmadakis G; Karellas S Open Res Eur; 2022; 2():49. PubMed ID: 37645320 [TBL] [Abstract][Full Text] [Related]
17. Exergy Analysis of Phase-Change Heat-Storage Coupled Solar Heat Pump Heating System. Zhu C; Yan S; Dong X; Zhang W; Huang B; Cui Y Materials (Basel); 2021 Sep; 14(19):. PubMed ID: 34639948 [TBL] [Abstract][Full Text] [Related]
18. Performance analysis of photovoltaic-thermal air collectors combined with a water to air heat exchanger for renewed air conditioning in building. Hachchadi O; Bououd M; Mechaqrane A Environ Sci Pollut Res Int; 2021 Apr; 28(15):18953-18962. PubMed ID: 32080816 [TBL] [Abstract][Full Text] [Related]
19. Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions. Onyeocha EI; Nwaigwe KN; Ogueke NV; Anyanwu EE Heliyon; 2020 Sep; 6(9):e04838. PubMed ID: 32939418 [TBL] [Abstract][Full Text] [Related]
20. Minimum ignition energies and laminar burning velocities of ammonia, HFO-1234yf, HFC-32 and their mixtures with carbon dioxide, HFC-125 and HFC-134a. Sadaghiani MS; Arami-Niya A; Zhang D; Tsuji T; Tanaka Y; Seiki Y; May EF J Hazard Mater; 2021 Apr; 407():124781. PubMed ID: 33412363 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]