145 related articles for article (PubMed ID: 3928309)
1. Nitroglycerin adsorption to a combination polyvinyl chloride, polyethylene intravenous administration set.
Schaber DE; Uden DL; McCoy HG
Drug Intell Clin Pharm; 1985; 19(7-8):572-5. PubMed ID: 3928309
[TBL] [Abstract][Full Text] [Related]
2. Intravenous nitroglycerin perfusion techniques--clinical implications.
Hans P; Paris P; Mathot F
Intensive Care Med; 1982 Mar; 8(2):93-5. PubMed ID: 6804554
[TBL] [Abstract][Full Text] [Related]
3. Sorption of four drugs to polyvinyl chloride and polybutadiene intravenous administration sets.
Lee MG
Am J Hosp Pharm; 1986 Aug; 43(8):1945-50. PubMed ID: 3092648
[TBL] [Abstract][Full Text] [Related]
4. Sorption of amiodarone to polyvinyl chloride infusion bags and administration sets.
Weir SJ; Myers VA; Bengtson KD; Ueda CT
Am J Hosp Pharm; 1985 Dec; 42(12):2679-83. PubMed ID: 4083289
[TBL] [Abstract][Full Text] [Related]
5. [Loss of intravenous nitroglycerin administered with polyvinyl chloride infusion systems].
Barranco Ruiz F; Sánchez Alarcón MA; Lesmes Serrano A; Martínez Ruiz D; Barranco Sánchez R
Med Clin (Barc); 1991 Feb; 96(4):129-31. PubMed ID: 1902541
[TBL] [Abstract][Full Text] [Related]
6. Nitroglycerin delivery through a polyethylene-lined intravenous administration set.
Tracy TS; Bowman L; Black CD
Am J Hosp Pharm; 1989 Oct; 46(10):2031-5. PubMed ID: 2510512
[TBL] [Abstract][Full Text] [Related]
7. Effect of a polyethylene-lined administration set on the availability of diazepam injection.
Hancock BG; Black CD
Am J Hosp Pharm; 1985 Feb; 42(2):335-9. PubMed ID: 3976681
[TBL] [Abstract][Full Text] [Related]
8. The availability of nitroglycerin from parenteral solutions.
Roberts MS; Cossum PA; Galbraith AJ; Boyd GW
J Pharm Pharmacol; 1980 Apr; 32(4):237-44. PubMed ID: 6103051
[TBL] [Abstract][Full Text] [Related]
9. Nitroglycerin compatibility with intravenous fluid filters, containers, and administration sets.
Baaske DM; Amann AH; Wagenknecht DM; Mooers M; Carter JE; Hoyt HJ; Stoll RG
Am J Hosp Pharm; 1980 Feb; 37(2):201-5. PubMed ID: 6767400
[TBL] [Abstract][Full Text] [Related]
10. Effects of presaturation on nitroglycerin delivery by polyvinyl chloride infusion sets.
Nix DE; Tharpe WN; Francisco GE
Am J Hosp Pharm; 1984 Sep; 41(9):1835-7. PubMed ID: 6437222
[No Abstract] [Full Text] [Related]
11. Sorption of various drugs in polyvinyl chloride, glass, and polyethylene-lined infusion containers.
Martens HJ; De Goede PN; Van Loenen AC
Am J Hosp Pharm; 1990 Feb; 47(2):369-73. PubMed ID: 2309728
[TBL] [Abstract][Full Text] [Related]
12. Insulin adsorption to polyolefin infusion bottles and polyvinyl chloride administration sets.
Hirsch JI; Wood JH; Thomas RB
Am J Hosp Pharm; 1981 Jul; 38(7):995-7. PubMed ID: 7020415
[TBL] [Abstract][Full Text] [Related]
13. Sorptive loss of diazepam and nitroglycerin from solutions to three types of containers.
Yliruusi JK; Sothmann AG; Laine RH; Rajasilta RA; Kristoffersson ER
Am J Hosp Pharm; 1982 Jun; 39(6):1018-21. PubMed ID: 6808834
[TBL] [Abstract][Full Text] [Related]
14. Specialized delivery systems for intravenous nitroglycerin. Are they necessary?
Young JB; Pratt CM; Farmer JA; Luck JC; Fennell WH; Roberts R
Am J Med; 1984 Jun; 76(6A):27-37. PubMed ID: 6430075
[TBL] [Abstract][Full Text] [Related]
15. Effect of infusion administration set on the delivery rate and plasma concentration of nitroglycerin in dogs.
McNiff EF; Lai CM; Look ZM; Yacobi A; Fung HL
J Pharm Sci; 1985 Jul; 74(7):774-6. PubMed ID: 3928871
[TBL] [Abstract][Full Text] [Related]
16. Effect of tubing length on adsorption of diazepam to polyvinyl chloride administration sets.
Yliruusi JK; Uotila JA; Kristoffersson ER
Am J Hosp Pharm; 1986 Nov; 43(11):2789-94. PubMed ID: 3799616
[TBL] [Abstract][Full Text] [Related]
17. Stability and sorption of FK 506 in 5% dextrose injection and 0.9% sodium chloride injection in glass, polyvinyl chloride, and polyolefin containers.
Taormina D; Abdallah HY; Venkataramanan R; Logue L; Burckart GJ; Ptachcinski RJ; Todo S; Fung JJ; Starzl TE
Am J Hosp Pharm; 1992 Jan; 49(1):119-22. PubMed ID: 1373936
[TBL] [Abstract][Full Text] [Related]
18. Clinical response to intravenous nitroglycerin infused through polyethylene or polyvinyl chloride tubing.
Altavela JL; Haas CE; Nowak DR; Powers J; Gacioch GM
Am J Hosp Pharm; 1994 Feb; 51(4):490-4. PubMed ID: 8017414
[TBL] [Abstract][Full Text] [Related]
19. Factors affecting the availability of diazepam stored in plastic bags and administered through intravenous sets.
Kowaluk EA; Roberts MS; Polack AE
Am J Hosp Pharm; 1983 Mar; 40(3):417-23. PubMed ID: 6846350
[TBL] [Abstract][Full Text] [Related]
20. Availability of diazepam from plastic containers.
Cloyd JC; Vezeau C; Miller KW
Am J Hosp Pharm; 1980 Apr; 37(4):492-6. PubMed ID: 7377211
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]