These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 39346330)

  • 1. Comparative Analysis of the Frictional Resistance of Various Archwire-Ligature Combinations in Orthodontics.
    Alam MK; Alfuhigi MZ; Hajeer MY; Alsenani FN; Eldosary FA; Alsayil LN
    J Pharm Bioallied Sci; 2024 Jul; 16(Suppl 3):S2506-S2508. PubMed ID: 39346330
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.
    Nayak RS; Shafiuddin B; Pasha A; Vinay K; Narayan A; Shetty SV
    J Int Oral Health; 2015 Jul; 7(7):29-35. PubMed ID: 26229367
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Frictional resistance between orthodontic brackets and archwire: an in vitro study.
    Husain N; Kumar A
    J Contemp Dent Pract; 2011 Mar; 12(2):91-9. PubMed ID: 22186750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative study of frictional resistance during simulated canine retraction on typodont model.
    Sukh R; Singh GK; Tandon P; Singh GP; Singh A
    J Orthod Sci; 2013 Apr; 2(2):61-6. PubMed ID: 24987644
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the friction forces delivered by different elastomeric patterns and metal ligature on conventional metal brackets with a NiTi arch wire versus a self-ligating system: An in vitro study.
    Pieroni M; Ferraz Facury AGB; Santamaria-Jr M; Correr AB; Correr-Sobrinho L; Vedovello Filho M; Costa AR; Neves JG
    Int Orthod; 2022 Jun; 20(2):100633. PubMed ID: 35339407
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Self-ligating Stainless Steel Brackets with different Dimensions of Archwires in Various Bracket-archwire Combination.
    Sridharan K; Sandbhor S; Rajasekaran UB; Sam G; Ramees MM; Abraham EA
    J Contemp Dent Pract; 2017 Aug; 18(8):660-664. PubMed ID: 28816185
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Frictional resistances using Teflon-coated ligatures with various bracket-archwire combinations.
    De Franco DJ; Spiller RE; von Fraunhofer JA
    Angle Orthod; 1995; 65(1):63-72; discussion 73-4. PubMed ID: 7726464
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of Various Archwire Materials and Their Impact on Orthodontic Treatment Outcomes.
    V S B; Kaul A; Tiwari A; Aliya S; Yadav A; Bera T; Kaur Makkad P
    Cureus; 2024 Sep; 16(9):e69667. PubMed ID: 39429425
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Friction behavior of ceramic injection-molded (CIM) brackets.
    Reimann S; Bourauel C; Weber A; Dirk C; Lietz T
    J Orofac Orthop; 2016 Jul; 77(4):262-71. PubMed ID: 27142040
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.
    Pasha A; Vishwakarma S; Narayan A; Vinay K; Shetty SV; Roy PP
    J Int Oral Health; 2015 Sep; 7(9):108-13. PubMed ID: 26435628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of friction of conventional and metal-insert ceramic brackets in various bracket-archwire combinations.
    Cacciafesta V; Sfondrini MF; Scribante A; Klersy C; Auricchio F
    Am J Orthod Dentofacial Orthop; 2003 Oct; 124(4):403-9. PubMed ID: 14560270
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations.
    Monteiro MR; Silva LE; Elias CN; Vilella Ode V
    J Appl Oral Sci; 2014 Jun; 22(3):228-34. PubMed ID: 25025564
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A study of frictional forces between orthodontic brackets and archwires.
    Downing A; McCabe J; Gordon P
    Br J Orthod; 1994 Nov; 21(4):349-57. PubMed ID: 7857894
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance.
    Tecco S; Di Iorio D; Cordasco G; Verrocchi I; Festa F
    Eur J Orthod; 2007 Aug; 29(4):390-7. PubMed ID: 17702800
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative Evaluation of Frictional Resistance Between Different Types of Ceramic Brackets and Stainless Steel Brackets With Teflon-Coated Stainless Steel and Stainless Steel Archwires: An In-Vitro Study.
    Bhat KRR; Ahmed N; Joseph R; Younus A A
    Cureus; 2022 Apr; 14(4):e24161. PubMed ID: 35586355
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations.
    Cacciafesta V; Sfondrini MF; Ricciardi A; Scribante A; Klersy C; Auricchio F
    Am J Orthod Dentofacial Orthop; 2003 Oct; 124(4):395-402. PubMed ID: 14560269
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Friction between Archwire of Different Sizes, Cross Section, Alloy and Brackets Ligated with Different Brands of Low Friction Elastic Ligatures- An Invitro Study.
    Patil B; Patil NS; Kerudi VV; Chitko SS; Maheshwari AR; Patil HA; Pekhale NP; Tekale PD
    J Clin Diagn Res; 2016 Apr; 10(4):ZC18-22. PubMed ID: 27190944
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets.
    Cash A; Curtis R; Garrigia-Majo D; McDonald F
    Eur J Orthod; 2004 Feb; 26(1):105-11. PubMed ID: 14994890
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets.
    Matarese G; Nucera R; Militi A; Mazza M; Portelli M; Festa F; Cordasco G
    Am J Orthod Dentofacial Orthop; 2008 May; 133(5):708-15. PubMed ID: 18456144
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys.
    Krishnan M; Kalathil S; Abraham KM
    Am J Orthod Dentofacial Orthop; 2009 Nov; 136(5):675-82. PubMed ID: 19892284
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.