These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 39381247)

  • 1. Mitigating aerosol-induced respiratory infections in home quarantine: The role of door dynamics and ventilation in residential design.
    Wu X; Han M; Chen H
    Heliyon; 2024 Sep; 10(18):e37967. PubMed ID: 39381247
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Large Eddy Simulation of Air Escape through a Hospital Isolation Room Single Hinged Doorway--Validation by Using Tracer Gases and Simulated Smoke Videos.
    Saarinen PE; Kalliomäki P; Tang JW; Koskela H
    PLoS One; 2015; 10(7):e0130667. PubMed ID: 26151865
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of aerosol transmission risk during home quarantine under different operating scenarios: A pilot study.
    Cheung T; Li J; Goh J; Sekhar C; Cheong D; Tham KW
    Build Environ; 2022 Nov; 225():109640. PubMed ID: 36210963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Large-eddy simulation of the containment failure in isolation rooms with a sliding door-An experimental and modelling study.
    Saarinen P; Kalliomäki P; Koskela H; Tang JW
    Build Simul; 2018; 11(3):585-596. PubMed ID: 32218903
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of National Aerosol Facility (NAF) in Designing of a Ventilation System for Isolation Rooms to Minimize Interpersonal Exposure of Sneezing/Coughing.
    Singh RK; Tripathi SN
    Trans Indian Natl Acad Eng; 2020; 5(2):263-267. PubMed ID: 38624304
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room.
    Thatiparti DS; Ghia U; Mead KR
    Sci Technol Built Environ; 2016; 23(2):355-366. PubMed ID: 28736744
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of aerosol persistence in ICUs via low-cost sensor network and zonal models.
    Glenn K; He J; Rochlin R; Teng S; Hecker JG; Novosselov I
    Sci Rep; 2023 Mar; 13(1):3992. PubMed ID: 36899063
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aerosol exchange between pressure-equilibrium rooms induced by door motion and human movement.
    Zheng M; Fan Y; Li X; Lester D; Chen X; Li Y; Cole I
    Build Environ; 2023 Aug; 241():110486. PubMed ID: 37287526
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Role of ventilation on the transmission of viruses in buildings, from a single zone to a multizone approach.
    Guyot G; Sayah S; Guernouti S; Mélois A
    Indoor Air; 2022 Aug; 32(8):e13097. PubMed ID: 36040282
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pilot Evaluation of Possible Airborne Transmission in a Geriatric Care Facility Using Carbon Dioxide Tracer Gas: Case Study.
    Ishigaki Y; Yokogawa S; Minamoto Y; Saito A; Kitamura H; Kawauchi Y
    JMIR Form Res; 2022 Dec; 6(12):e37587. PubMed ID: 36583933
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.
    Li Y; Huang X; Yu IT; Wong TW; Qian H
    Indoor Air; 2005 Apr; 15(2):83-95. PubMed ID: 15737151
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aerodynamic analysis of hospital ventilation according to seasonal variations. A simulation approach to prevent airborne viral transmission pathway during Covid-19 pandemic.
    Beaussier M; Vanoli E; Zadegan F; Peray H; Bezian E; Jilesen J; Gandveau G; Gayraud JM
    Environ Int; 2022 Jan; 158():106872. PubMed ID: 34547639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Natural ventilation for the prevention of airborne contagion.
    Escombe AR; Oeser CC; Gilman RH; Navincopa M; Ticona E; Pan W; Martínez C; Chacaltana J; Rodríguez R; Moore DA; Friedland JS; Evans CA
    PLoS Med; 2007 Feb; 4(2):e68. PubMed ID: 17326709
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Directional Airflow and Ventilation in Hospitals: A Case Study of Secondary Airborne Infection.
    Mousavi ES; Grosskopf KR
    Energy Procedia; 2015 Nov; 78():1201-1206. PubMed ID: 32288886
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Airflow patterns through single hinged and sliding doors in hospital isolation rooms - Effect of ventilation, flow differential and passage.
    Kalliomäki P; Saarinen P; Tang JW; Koskela H
    Build Environ; 2016 Oct; 107():154-168. PubMed ID: 32287966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a non-contact mobile screening center for infectious diseases: Effects of ventilation improvement on aerosol transmission prevention.
    Cho J; Kim J; Kim Y
    Sustain Cities Soc; 2022 Dec; 87():104232. PubMed ID: 36212168
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Virus diffusion in isolation rooms.
    Kao PH; Yang RJ
    J Hosp Infect; 2006 Mar; 62(3):338-45. PubMed ID: 16359753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hospital and community acquired infection and the built environment--design and testing of infection control rooms.
    Walker JT; Hoffman P; Bennett AM; Vos MC; Thomas M; Tomlinson N
    J Hosp Infect; 2007 Jun; 65 Suppl 2():43-9. PubMed ID: 17540241
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Infectious Aerosol Capture Mask as Environmental Control to Reduce Spread of Respiratory Viral Particles.
    Santarpia JL; Markin NW; Herrera VL; Ackerman DN; Rivera DN; Lucero GA; Lisco SJ
    Viruses; 2022 Jun; 14(6):. PubMed ID: 35746746
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E, Amoy Gardens.
    Li Y; Duan S; Yu IT; Wong TW
    Indoor Air; 2005 Apr; 15(2):96-111. PubMed ID: 15737152
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.