These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 39388258)

  • 1. Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis.
    Singh S; Bennett MR; Chen C; Shin S; Ghanbari H; Nelson BW
    J Med Internet Res; 2024 Oct; 26():e62769. PubMed ID: 39388258
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis.
    Shi C; Goodall M; Dumville J; Hill J; Norman G; Hamer O; Clegg A; Watkins CL; Georgiou G; Hodkinson A; Lightbody CE; Dark P; Cullum N
    BMC Med; 2022 Aug; 20(1):267. PubMed ID: 35971142
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Smartphone Biosensor With App Meets FDA/ISO Standards for Clinical Pulse Oximetry and Can Be Reliably Used by a Wide Range of Patients.
    Browne SH; Bernstein M; Pan SC; Gonzalez Garcia J; Easson CA; Huang CC; Vaida F
    Chest; 2021 Feb; 159(2):724-732. PubMed ID: 32926871
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of Skin Pigmentation and Finger Choice on Accuracy of Oxygen Saturation Measurement in an IoT-Based Pulse Oximeter.
    Haxha S; Nwibor C; Ali M; Sakel M; Saunders K; Dyo V; Nabakooza S
    Sensors (Basel); 2024 May; 24(11):. PubMed ID: 38894093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of skin tone on the accuracy of the estimation of arterial oxygen saturation by pulse oximetry: a systematic review.
    Martin D; Johns C; Sorrell L; Healy E; Phull M; Olusanya S; Peters M; Fabes J
    Br J Anaesth; 2024 May; 132(5):945-956. PubMed ID: 38368234
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of skin pigmentation on pulse oximeter accuracy at low saturation.
    Bickler PE; Feiner JR; Severinghaus JW
    Anesthesiology; 2005 Apr; 102(4):715-9. PubMed ID: 15791098
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reducing racial bias in SpO
    Bermond M; Davies HJ; Occhipinti E; Nassibi A; Mandic DP
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-5. PubMed ID: 38083781
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of skin pigmentation-related bias in pulse oximetry readings among adults.
    Khanna AK; Beard J; Lamminmäki S; Närväinen J; Antaki N; Yapici HO
    J Clin Monit Comput; 2024 Feb; 38(1):113-120. PubMed ID: 37882880
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A review of the effect of skin pigmentation on pulse oximeter accuracy.
    Al-Halawani R; Charlton PH; Qassem M; Kyriacou PA
    Physiol Meas; 2023 Jun; 44(5):. PubMed ID: 37172609
    [No Abstract]   [Full Text] [Related]  

  • 10. Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study.
    Buekers J; Theunis J; De Boever P; Vaes AW; Koopman M; Janssen EV; Wouters EF; Spruit MA; Aerts JM
    JMIR Mhealth Uhealth; 2019 Jun; 7(6):e12866. PubMed ID: 31199331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wrist-Sensor Pulse Oximeter Enables Prolonged Patient Monitoring in Chronic Lung Diseases.
    Guber A; Epstein Shochet G; Kohn S; Shitrit D
    J Med Syst; 2019 Jun; 43(7):230. PubMed ID: 31201528
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR).
    Bradke B; Everman B
    Biosensors (Basel); 2020 Apr; 10(4):. PubMed ID: 32260393
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers.
    Bickler PE; Feiner JR; Rollins MD
    Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study.
    Hao S; Dempsey K; Matos J; Cox CE; Rotemberg V; Gichoya JW; Kibbe W; Hong C; Wong AI
    Crit Care Explor; 2024 Sep; 6(9):e1133. PubMed ID: 39268149
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of pulse oximetry in children.
    Ross PA; Newth CJ; Khemani RG
    Pediatrics; 2014 Jan; 133(1):22-9. PubMed ID: 24344108
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A motion-tolerant approach for monitoring SpO
    Fan F; Yan Y; Tang Y; Zhang H
    Comput Biol Med; 2017 Dec; 91():291-305. PubMed ID: 29102826
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determining factors of pulse oximetry accuracy: a literature review.
    León-Valladares D; Barrio-Mateu LA; Cortés-Carmona N; Fuentes-Lizana G; Cabanas AM; Latorre-Progulakis K; Fuentes-Guajardo M; Martín-Escudero P
    Rev Clin Esp (Barc); 2024 May; 224(5):314-330. PubMed ID: 38599519
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of a Wearable Ring in Controlled Hypoxia: A Prospective Observational Study.
    Mastrototaro JJ; Leabman M; Shumate J; Tompkins KL
    JMIR Form Res; 2024 Jun; 8():e54256. PubMed ID: 38838332
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender.
    Feiner JR; Severinghaus JW; Bickler PE
    Anesth Analg; 2007 Dec; 105(6 Suppl):S18-S23. PubMed ID: 18048893
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse oximetry in patients with pigmented skin: What I should know.
    Brookman S; Mukadam T; Owasil S; Thachettu A; Urquhart DS; Dhawan A; Gupta A
    Paediatr Respir Rev; 2024 Sep; 51():19-25. PubMed ID: 38960816
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.