These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 3939024)

  • 1. [Porous tarflen as a possible membrane material for blood membrane oxygenators. II. Diffusion properties].
    Krajewska B
    Polim Med; 1985; 15(3-4):125-34. PubMed ID: 3939024
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Porous tarflen as a possible membrane material for membrane blood oxygenators. III. O2 and CO2 transport in the system modeling an artificial lung].
    Krajewska B; Leszko M
    Polim Med; 1986; 16(1-2):3-17. PubMed ID: 3099272
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Porous tarflen as a possible membrane material in membrane blood oxygenators. I. Structural properties].
    Krajewska B; Leszko M
    Polim Med; 1985; 15(1-2):5-20. PubMed ID: 4048022
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Membrane oxygenators of the blood].
    Krajewska B; Leszko M
    Polim Med; 1983; 13(3-4):93-116. PubMed ID: 6438615
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Efficiency of membrane oxygenators of various designs under standard conditions].
    Vlasov VM; Karichev ZR; Muler AL
    Med Tekh; 1987; (5):50-5. PubMed ID: 3121977
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Diffusion of oxygen and carbon dioxide in a stationary membrane oxygenator].
    Gorun VT; Karichev ZR; Levitskiĭ GIa
    Med Tekh; 1976; (4):19-26. PubMed ID: 1030765
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the gas transfer characteristics of porous copolyurethane oxygenator membranes.
    Knight PM; Lyman DJ
    Ann Biomed Eng; 1985; 13(1):25-41. PubMed ID: 3923874
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of an implantable oxygenator with cross-flow pump.
    Asakawa Y; Funakubo A; Fukunaga K; Taga I; Higami T; Kawamura T; Fukui Y
    ASAIO J; 2006; 52(3):291-5. PubMed ID: 16760718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tightly wound coils of microporous tubing: progress with secondary-flow blood oxygenator design.
    Tanishita K; Richardson PD; Galletti PM
    Trans Am Soc Artif Intern Organs; 1975; 21():216-23. PubMed ID: 1145994
    [No Abstract]   [Full Text] [Related]  

  • 10. [Transport of carbon dioxide in membrane oxygenators].
    Vlasov VM; Karichev ZR; Muler AL; Isaev IuV
    Med Tekh; 1987; (5):19-26. PubMed ID: 3121976
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Artificial "membranous lung"].
    Pisarevskiĭ AA; Doletskiĭ AS; Kutepov PV; Karasev AB
    Med Tekh; 1976; (4):44-50. PubMed ID: 799747
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a novel polyimide hollow fiber for an intravascular oxygenator.
    Kawakami H; Mori Y; Takagi J; Nagaoka S; Kanamori T; Shinbo T; Kubota S
    ASAIO J; 1997; 43(5):M490-4. PubMed ID: 9360091
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Experimental evaluation of a new membrane oxygenator (Travenol-Modulung 5 MO 914) (author's transl)].
    Bornikoel K; Hagl S; Mayr N; Mendler N; Sebening F
    Thoraxchir Vask Chir; 1974 Aug; 22(4):331-40. PubMed ID: 4548248
    [No Abstract]   [Full Text] [Related]  

  • 14. Novel concept for pure diffusive capillary membrane oxygenators: silicone hollow sphere (SiHSp) fibers.
    Khachab A; Tabesh H; Kashefi A; Mottaghy K
    ASAIO J; 2013; 59(2):162-8. PubMed ID: 23438780
    [TBL] [Abstract][Full Text] [Related]  

  • 15. From pulsating to tubular flow membrane-oxygenator.
    Birnbaum D; Kaiser M
    Life Support Syst; 1984; 2(4):281-6. PubMed ID: 6441874
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental evaluation of Gore-Tex membrane oxygenator.
    Esato K; Eiseman B
    J Thorac Cardiovasc Surg; 1975 May; 69(5):690-7. PubMed ID: 1127968
    [No Abstract]   [Full Text] [Related]  

  • 17. Limiting models for the transfer of CO2 and O2 in membrane oxygenators.
    Dorson WJ; Voorhees M
    Trans Am Soc Artif Intern Organs; 1974; 20A():219-26. PubMed ID: 4450341
    [No Abstract]   [Full Text] [Related]  

  • 18. Blood oxygenation in extracorporeal devices: theoretical considerations.
    Spaeth EE
    CRC Crit Rev Bioeng; 1973 Aug; 1(4):383-417. PubMed ID: 4581807
    [No Abstract]   [Full Text] [Related]  

  • 19. Laboratory and clinical experience with a microporous membrane oxygenator.
    Murphy W; Trudell LA; Friedman LI; Kakvan M; Richardson PD; Karlson K; Galletti PM
    Trans Am Soc Artif Intern Organs; 1974; 20A():278-85. PubMed ID: 4450349
    [No Abstract]   [Full Text] [Related]  

  • 20. [Evaluation of the structure and function of a hollow fiber membrane oxygenator].
    Masuda M; Tokunaga K; Sakai H; Shiraishi K
    Nihon Rinsho; 1985 Dec; 43(12):2583-6. PubMed ID: 3938994
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.