BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

64 related articles for article (PubMed ID: 3939271)

  • 21. Acceleration of neointima formation in vascular prostheses by transplantation of autologous venous tissue fragments. Application to small-diameter grafts.
    Noishiki Y; Tomizawa Y; Yamane Y; Okoshi T; Satoh S; Matsumoto A
    J Thorac Cardiovasc Surg; 1993 May; 105(5):796-804. PubMed ID: 8487559
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Construction and animal experiment studies of a small-lumen microporous polyurethane vascular prosthesis].
    Braun B; Grande PU; Lehnhardt FJ; Jerusalem C; Hess F
    Vasa Suppl; 1988; 22():1-38. PubMed ID: 3164528
    [No Abstract]   [Full Text] [Related]  

  • 23. Novel bioengineered small caliber vascular graft with excellent one-month patency.
    Ishii Y; Kronengold RT; Virmani R; Rivera EA; Goldman SM; Prechtel EJ; Schuessler RB; Damiano RJ
    Ann Thorac Surg; 2007 Feb; 83(2):517-25. PubMed ID: 17257981
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Scanning electron microscopy evaluation of porous and nonporous arterial substitutes.
    Ratto GB; Lunghi C; Spinelli E; Agati R; Tomellini M; Motta G
    Surg Gynecol Obstet; 1982 Sep; 155(3):358-62. PubMed ID: 6214034
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Application of porous heparinized polymer to vascular graft.
    Noishiki Y; Nagaoka S; Kikuchi T; Mori Y
    Trans Am Soc Artif Intern Organs; 1981; 27():213-8. PubMed ID: 7331077
    [No Abstract]   [Full Text] [Related]  

  • 26. The importance of zeta potential, ultrastructure, and electrical conductivity to the in vivo performance of polyurethane-carbon black vascular prostheses.
    Taylor BC; Sharp WV; Wright JI; Ewing KL; Wilson CL
    Trans Am Soc Artif Intern Organs; 1971; 17():22-6. PubMed ID: 5158098
    [No Abstract]   [Full Text] [Related]  

  • 27. Thrombin-free fibrin coating on small caliber vascular prostheses has high antithrombogenicity in rabbit model.
    Hasegawa T; Okada K; Takano Y; Hiraishi Y; Okita Y
    Artif Organs; 2005 Nov; 29(11):880-6. PubMed ID: 16266301
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Healing pattern of small caliber dacron grafts in the baboon: an animal model for the study of vascular prostheses.
    Keough EM; Callow AD; Connolly RJ; Weinberg KS; Aalberg JJ; O'Donnell TF
    J Biomed Mater Res; 1984 Mar; 18(3):281-92. PubMed ID: 6232280
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Seeding of human vascular cells onto small diameter polyurethane vascular grafts.
    Gulbins H; Pritisanac A; Dauner M; Petzold R; Goldemund A; Doser M; Meiser B; Reichart B
    Thorac Cardiovasc Surg; 2006 Mar; 54(2):102-7. PubMed ID: 16541350
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Prosthetic substitution of the inferior vena cava: use of a new material (mitrathane). Short term results].
    Colli R; Cina G; Ferrante A; Maggiano N; Castagnola M; Di Giovanni V
    Chir Patol Sper; 1984 Jul; 32(3):111-27. PubMed ID: 6549596
    [No Abstract]   [Full Text] [Related]  

  • 31. Healing characteristics of polymer-coated or collagen-treated Dacron grafts: an experimental porcine study.
    Pärsson H; Jundzill W; Johansson K; Jonung T; Norgren L
    Cardiovasc Surg; 1994 Apr; 2(2):242-8. PubMed ID: 8049955
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In vivo biocompatibility of sulfonated PEO-grafted polyurethanes for polymer heart valve and vascular graft.
    Han DK; Park K; Park KD; Ahn KD; Kim YH
    Artif Organs; 2006 Dec; 30(12):955-9. PubMed ID: 17181836
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Electrically-spun polyurethane vascular prostheses.
    Williams DF
    J Biomed Mater Res; 1986; 20(6):v-vi. PubMed ID: 3722209
    [No Abstract]   [Full Text] [Related]  

  • 34. [On preclotting of woven Dacron vascular prostheses (author's transl)].
    Topping C; Guidoin R; Roy J; Picard R; Bernier J; Gosselin C; Blais P; Martin L; Marois M; Noël HP
    J Chir (Paris); 1980; 117(6-7):403-9. PubMed ID: 6448259
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Roughness and thrombogenicity of the outer surfaces of intravascular catheters.
    Hecker JF; Scandrett LA
    J Biomed Mater Res; 1985 Apr; 19(4):381-95. PubMed ID: 4055822
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Small vessel replacement by human umbilical arteries with polyelectrolyte film-treated arteries: in vivo behavior.
    Kerdjoudj H; Berthelemy N; Rinckenbach S; Kearney-Schwartz A; Montagne K; Schaaf P; Lacolley P; Stoltz JF; Voegel JC; Menu P
    J Am Coll Cardiol; 2008 Nov; 52(19):1589-97. PubMed ID: 19007598
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Synthesis of a new photoreactive derivative of dipyridamole and its use in the manufacture of artificial surfaces with low thrombogenicity.
    Aldenhoff YB; Pijpers AP; Koole LH
    Bioconjug Chem; 1997; 8(3):296-303. PubMed ID: 9177834
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A study of the interface between a fibrous polyurethane arterial prosthesis and natural tissue.
    Beahan P; Hull D
    J Biomed Mater Res; 1982 Nov; 16(6):827-38. PubMed ID: 6757256
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of a new antithrombogenic polyurethane-polysiloxane complex biomaterial.
    Ohkubo N; Hirose H; Matsuda H; Nakano S; Shirakura R; Maeda S; Ohtani M; Yoda R; Kawashima Y
    ASAIO Trans; 1986; 32(1):193-7. PubMed ID: 3778711
    [No Abstract]   [Full Text] [Related]  

  • 40. Small-caliber biodegradable vascular grafts from Groningen.
    Gogolewski S; Pennings AJ; Lommen E; Wildevuur CR
    Life Support Syst; 1983; 1 Suppl 1():382-5. PubMed ID: 6336450
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.