These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 3941556)

  • 1. The entrapped balloon: report of a possibly serious complication.
    Aru GM; King JT; Hovaguimian H; Floten HS; Ahmad A; Starr A
    J Thorac Cardiovasc Surg; 1986 Jan; 91(1):146-9. PubMed ID: 3941556
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A case of emergency operation of entrapped intra-aortic balloon].
    Nakayama Y; Naito K; Sakai M; Natsuaki M; Itoh T
    Kyobu Geka; 1992 Sep; 45(10):932-4. PubMed ID: 1518213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Femoral artery pseudoaneurysm by intraaortic balloon pumping].
    Koyanagi T; Endo M; Siikawa A; Akiyama K; Koyanagi H
    Nihon Geka Gakkai Zasshi; 1990 Apr; 91(4):529-32. PubMed ID: 2377167
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Limb ischemia during intra-aortic balloon pumping: indication for femorofemoral crossover graft.
    Alpert J; Parsonnet V; Goldenkranz RJ; Bhaktan EK; Brief DK; Brener BJ; Gielchinsky I; Abel RM
    J Thorac Cardiovasc Surg; 1980 May; 79(5):729-34. PubMed ID: 7366238
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pseudoaneurysm following balloon counterpulsation.
    Macmanus Q; Lefrak EA
    Va Med; 1982 Jul; 109(7):471-2. PubMed ID: 7124096
    [No Abstract]   [Full Text] [Related]  

  • 6. Treatment of femoral artery thrombosis following intra-aortic balloon insertion leaving the catheter in place.
    Georgiadis GS; Lazarides MK; Didilis VN; Mikroulis DA; Bougioukas GI
    J Cardiovasc Surg (Torino); 2003 Feb; 44(1):149-50. PubMed ID: 12627091
    [No Abstract]   [Full Text] [Related]  

  • 7. Intraaortic balloon entrapment: a complication of balloon perforation.
    Milgalter E; Mosseri M; Uretzky G; Romanoff H
    Ann Thorac Surg; 1986 Dec; 42(6):697-8. PubMed ID: 3789861
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A technique for removal of entrapped intra-aortic balloon catheter through the left axillary artery].
    Fukushima Y; Yoshioka M; Hayase T; Taniguchi M; Hirayama N; Unoki T; Kashiwagi T; Koga Y
    Kyobu Geka; 1995 Sep; 48(10):880-2. PubMed ID: 7474593
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intra-aortic balloon pump related thrombus in the proximal descending thoracic aorta with peripheral emboli.
    Kloppenburg GT; Sonker U; Schepens MA
    J Invasive Cardiol; 2009 Jun; 21(6):e110-2. PubMed ID: 19494416
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A case report of successful removal of entrapped IABP by Lambert's method].
    Takazawa A; Tsuchida K; Kijima M; Matsumoto S; Igarashi M; Hashimoto H; Soeda N; Fujita S
    Kyobu Geka; 1993 May; 46(5):435-7. PubMed ID: 8492499
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relative risk of aortic and femoral insertion of intraaortic balloon pump after coronary artery bypass grafting procedures.
    Pinkard J; Utley JR; Leyland SA; Morgan M; Johnson H
    J Thorac Cardiovasc Surg; 1993 Apr; 105(4):721-8. PubMed ID: 8469005
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intra-aortic balloon pumping in children undergoing cardiac surgery: an update of the Liverpool experience.
    Kalavrouziotis G; Karunaratne A; Raja S; Ciotti G; Purohit M; Corno AF; Pozzi M
    J Thorac Cardiovasc Surg; 2006 Jun; 131(6):1382-1382.e10. PubMed ID: 16733173
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Complications associated with use of the intra-aortic balloon pump.
    Goldman BS; Hill TJ; Rosenthal GA; Scully HE; Weisel RD; Baird RJ
    Can J Surg; 1982 Mar; 25(2):153-6. PubMed ID: 7066775
    [No Abstract]   [Full Text] [Related]  

  • 14. Surgical versus percutaneous removal of the intra-aortic balloon.
    Cutler BS; Okike ON; Vander Salm TJ
    J Thorac Cardiovasc Surg; 1983 Dec; 86(6):907-11. PubMed ID: 6645593
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Peri-operative intraaortic balloon assist, decreasing complications to the minimum.
    Robicsek F; Holleman JH; Roush TS; Skipper ER; Robicsek SA; Lyons M
    Thorac Cardiovasc Surg; 2003 Jun; 51(3):115-25. PubMed ID: 12833199
    [No Abstract]   [Full Text] [Related]  

  • 16. [Immediate and long-term complications of counterpulsation balloon. Recent data apropos of a series of 200 consecutive patients].
    Eltchaninoff H; Whitlow PL
    Arch Mal Coeur Vaiss; 1993 Oct; 86(10):1465-70. PubMed ID: 8010845
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Entrapping of the clotted intra-aortic balloon in the descending aorta.
    Shafei H; Webb G; Lennox SC
    Eur J Cardiothorac Surg; 1991; 5(3):165-6. PubMed ID: 2025443
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retained intraaortic balloon. Case report and review of the literature.
    Grande AM; Martinelli L; Graffigna A; ViganĂ² M
    Tex Heart Inst J; 1995; 22(4):332-4. PubMed ID: 8605436
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intra-aortic balloon rupture causing femoral entrapment.
    Alvarez JM; Brady PW; Mc Wilson R
    Aust N Z J Surg; 1993 Jan; 63(1):72-4. PubMed ID: 8466467
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous intraaortic balloon support--repeat insertion through the same site.
    Holter AR; Bassett JE; Lind BC; Sharon MW
    Minn Med; 1982 Jul; 65(7):437-8. PubMed ID: 7110112
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.