These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 39422339)

  • 1. Four-Dimensional Impedance Manometry in Esophageal Motility Disorders.
    Goudie E; Kou W; Pandolfino JE; Araujo IK; Pitisuttithum P; Halder S; Kahrilas PJ; Carlson DA
    Am J Gastroenterol; 2024 Oct; ():. PubMed ID: 39422339
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The broad impact of functional lumen imaging probe panometry in addition to high-resolution manometry in an esophageal clinical practice.
    Ellison A; Nguyen AD; Zhang J; Mendoza R; Davis D; Podgaetz E; Ward M; Reddy C; Souza R; Spechler SJ; Konda VJA
    Dis Esophagus; 2023 Feb; 36(3):. PubMed ID: 36125222
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Relaxation of the lower esophageal sphincter in response to reduced volume distension during FLIP Panometry.
    Wakim El-Khoury J; Pandolfino JE; Kahrilas PJ; Godo B; Farina DA; Kou W; Carlson DA
    Neurogastroenterol Motil; 2023 Nov; 35(11):e14663. PubMed ID: 37691556
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of Clinically Relevant Thresholds of Esophagogastric Junction Obstruction Using FLIP Panometry.
    Carlson DA; Prescott JE; Baumann AJ; Schauer JM; Krause A; Donnan EN; Kou W; Kahrilas PJ; Pandolfino JE
    Clin Gastroenterol Hepatol; 2022 Jun; 20(6):e1250-e1262. PubMed ID: 34216821
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of Esophageal Motility Utilizing the Functional Lumen Imaging Probe.
    Carlson DA; Kahrilas PJ; Lin Z; Hirano I; Gonsalves N; Listernick Z; Ritter K; Tye M; Ponds FA; Wong I; Pandolfino JE
    Am J Gastroenterol; 2016 Dec; 111(12):1726-1735. PubMed ID: 27725650
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Normal Functional Luminal Imaging Probe Panometry Findings Associate With Lack of Major Esophageal Motility Disorder on High-Resolution Manometry.
    Baumann AJ; Donnan EN; Triggs JR; Kou W; Prescott J; Decorrevont A; Dorian E; Kahrilas PJ; Pandolfino JE; Carlson DA
    Clin Gastroenterol Hepatol; 2021 Feb; 19(2):259-268.e1. PubMed ID: 32205217
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluating esophageal motility beyond primary peristalsis: Assessing esophagogastric junction opening mechanics and secondary peristalsis in patients with normal manometry.
    Carlson DA; Baumann AJ; Donnan EN; Krause A; Kou W; Pandolfino JE
    Neurogastroenterol Motil; 2021 Oct; 33(10):e14116. PubMed ID: 33705590
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Normative values of intra-bolus pressure and esophageal compliance based on 4D high-resolution impedance manometry.
    Kou W; Carlson DA; Kahrilas PJ; Patankar NA; Pandolfino JE
    Neurogastroenterol Motil; 2022 Oct; 34(10):e14423. PubMed ID: 35661346
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interrater Reliability of Functional Lumen Imaging Probe Panometry and High-Resolution Manometry for the Assessment of Esophageal Motility Disorders.
    Chen JW; Khan A; Chokshi RV; Clarke JO; Fass R; Garza JM; Gupta M; Gyawali CP; Jain AS; Katz P; Konda V; Lazarescu A; Lynch KL; Schnoll-Sussman F; Spechler SJ; Vela MF; Yadlapati R; Schauer JM; Kahrilas PJ; Pandolfino JE; Carlson DA
    Am J Gastroenterol; 2023 Aug; 118(8):1334-1343. PubMed ID: 37042784
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Four-dimensional impedance manometry volume metrics for predicting abnormal bolus retention.
    Pitisuttithum P; Goudie E; Araujo IK; Halder S; Carlson DA; Pandolfino JE; Kou W
    Neurogastroenterol Motil; 2024 Jul; 36(7):e14803. PubMed ID: 38676387
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Functional Lumen Imaging Probe Panometry Helps Identify Clinically Relevant Esophagogastric Junction Outflow Obstruction per Chicago Classification v4.0.
    Carlson DA; Schauer JM; Kou W; Kahrilas PJ; Pandolfino JE
    Am J Gastroenterol; 2023 Jan; 118(1):77-86. PubMed ID: 36002925
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Classifying Esophageal Motility by FLIP Panometry: A Study of 722 Subjects With Manometry.
    Carlson DA; Gyawali CP; Khan A; Yadlapati R; Chen J; Chokshi RV; Clarke JO; Garza JM; Jain AS; Katz P; Konda V; Lynch K; Schnoll-Sussman FH; Spechler SJ; Vela MF; Prescott JE; Baumann AJ; Donnan EN; Kou W; Kahrilas PJ; Pandolfino JE
    Am J Gastroenterol; 2021 Dec; 116(12):2357-2366. PubMed ID: 34668487
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Solid Swallow Examination During High Resolution Manometry and EGJ-Distensibility Help Identify Esophageal Outflow Obstruction in Non-obstructive Dysphagia.
    Murray FR; Fischbach LM; Schindler V; Schnurre L; Hente JM; Tatu A; Pohl D
    Dysphagia; 2022 Feb; 37(1):168-176. PubMed ID: 33609164
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimating Probability for Esophageal Obstruction: A Diagnostic Decision Support Tool Applying Machine Learning to Functional Lumen Imaging Probe Panometry.
    Schauer JM; Kou W; Prescott JE; Kahrilas PJ; Pandolfino JE; Carlson DA
    J Neurogastroenterol Motil; 2022 Oct; 28(4):572-579. PubMed ID: 36250364
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prediction of Esophageal Retention: A Study Comparing High-Resolution Manometry and Functional Luminal Imaging Probe Panometry.
    Carlson DA; Baumann AJ; Prescott JE; Schauer JM; Krause A; Donnan EN; Kou W; Kahrilas PJ; Pandolfino JE
    Am J Gastroenterol; 2021 Oct; 116(10):2032-2041. PubMed ID: 34388142
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Devices for esophageal function testing.
    Pannala R; Krishnan K; Watson RR; Vela MF; Abu Dayyeh BK; Bhatt A; Bhutani MS; Bucobo JC; Chandrasekhara V; Copland AP; Jirapinyo P; Kumta NA; Law RJ; Maple JT; Melson J; Parsi MA; Rahimi EF; Saumoy M; Sethi A; Trikudanathan G; Trindade AJ; Yang J; Lichtenstein DR
    VideoGIE; 2022 Jan; 7(1):1-20. PubMed ID: 35059533
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Elevated intrabolus pressure identifies obstructive processes when integrated relaxation pressure is normal on esophageal high-resolution manometry.
    Quader F; Reddy C; Patel A; Gyawali CP
    Am J Physiol Gastrointest Liver Physiol; 2017 Jul; 313(1):G73-G79. PubMed ID: 28408642
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Secondary peristalsis and esophagogastric junction distensibility in symptomatic post-fundoplication patients.
    Lu MM; Kahrilas PJ; Teitelbaum EN; Pandolfino JE; Carlson DA
    Neurogastroenterol Motil; 2024 Apr; 36(4):e14746. PubMed ID: 38263867
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanisms of repetitive retrograde contractions in response to sustained esophageal distension: a study evaluating patients with postfundoplication dysphagia.
    Carlson DA; Kahrilas PJ; Ritter K; Lin Z; Pandolfino JE
    Am J Physiol Gastrointest Liver Physiol; 2018 Mar; 314(3):G334-G340. PubMed ID: 29351396
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Esophageal anatomy and physiology vary across spastic and non-spastic phenotypes of disorders of esophagogastric junction outflow.
    Vahedi F; Low EE; Kaizer AM; Fehmi SA; Hasan A; Chang MA; Kwong W; Krinsky ML; Anand G; Greytak M; Yadlapati R
    Neurogastroenterol Motil; 2024 Feb; 36(2):e14709. PubMed ID: 38009826
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.