These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 3943241)

  • 1. A false-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis.
    Feldman N; Makler PT; Alavi A
    Clin Nucl Med; 1986 Jan; 11(1):38-9. PubMed ID: 3943241
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Usefulness of scintigraphy with technetium-, gallium- and indium-labeled leukocytes in the diagnosis of septic loosening of total hip prostheses].
    Fernández Sabaté A; Fuster Obregón S; Ferrer Escobar H; Martín Comín J; Ricart Brulles Y
    Med Clin (Barc); 1987 Jun; 89(4):147-9. PubMed ID: 3626660
    [No Abstract]   [Full Text] [Related]  

  • 3. [The value of leukocyte scintigraphy in suspected implant infection in patients with chronic polyarthritis].
    Lazovic D; Carls J; Flöel A; Gratz KF
    Chirurg; 1997 Nov; 68(11):1181-6. PubMed ID: 9518212
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Indium-111 leucocyte scanning in the evaluation of painful hip arthroplasty.
    Mulamba L; Ferrant A; Leners N; de Nayer P; Rombouts JJ; Vincent A
    Acta Orthop Scand; 1983 Oct; 54(5):695-7. PubMed ID: 6670484
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Potential false-positive In-111 labeled leukocyte study in a patient with orthopedic hip arthroplasty.
    Trepashko DW; Pavel DG
    Clin Nucl Med; 1992 Mar; 17(3):239-40. PubMed ID: 1611800
    [No Abstract]   [Full Text] [Related]  

  • 6. Diagnosis of infection by preoperative scintigraphy with indium-labeled white blood cells.
    Wukich DK; Abreu SH; Callaghan JJ; Van Nostrand D; Savory CG; Eggli DF; Garcia JE; Berrey BH
    J Bone Joint Surg Am; 1987 Dec; 69(9):1353-60. PubMed ID: 3126189
    [TBL] [Abstract][Full Text] [Related]  

  • 7. False-positive radionuclide arthroscintigraphy with a porous-coated total hip prosthesis.
    Oswald SG; Herzwurm PJ
    Clin Nucl Med; 1991 Nov; 16(11):815-8. PubMed ID: 1752090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Abnormal bone marrow distribution following unsuccessful hip replacement: a potential confusion on white cell scanning.
    Cunningham DA
    Eur J Nucl Med; 1991; 18(1):67-9. PubMed ID: 2019282
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Arthroscintigraphic evaluation of the painful total hip prosthesis.
    Resnik CS; Fratkin MJ; Cardea JA
    Clin Nucl Med; 1986 Apr; 11(4):242-4. PubMed ID: 3956037
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnosing infection in the failed joint replacement: a comparison of coincidence detection 18F-FDG and 111In-labeled leukocyte/99mTc-sulfur colloid marrow imaging.
    Love C; Marwin SE; Tomas MB; Krauss ES; Tronco GG; Bhargava KK; Nichols KJ; Palestro CJ
    J Nucl Med; 2004 Nov; 45(11):1864-71. PubMed ID: 15534056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical problems in arthrography of the painful hip arthroplasty.
    Hankey S; McCall IW; Park WM; O'Connor BT
    Clin Radiol; 1979 Nov; 30(6):653-6. PubMed ID: 509866
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radionuclide arthrography and transmission imaging for assessment of painful hip prostheses.
    Hayes AA; Bower GD
    J Nucl Med; 1994 May; 35(5):851-4. PubMed ID: 8176470
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Indium-111 chloride imaging in chronic osteomyelitis.
    Sayle BA; Fawcett HD; Wilkey DJ; Cierny G; Mader JT
    J Nucl Med; 1985 Mar; 26(3):225-9. PubMed ID: 3882904
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Indium-111 chloride imaging in the detection of infected prostheses.
    Sayle BA; Fawcett HD; Wilkey DJ; Cierny G; Mader JT
    J Nucl Med; 1985 Jul; 26(7):718-21. PubMed ID: 4009282
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Scintigraphic evaluation of the painful prosthetic joint: a comparison of gallium-67 citrate and indium-111 labelled leucocyte imaging.
    McKillop JH; McKay I; Cuthbert GF; Fogelman I; Gray HW; Sturrock RD
    Clin Radiol; 1984 May; 35(3):239-41. PubMed ID: 6425000
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gallium-67 scanning in the painful total hip replacement.
    Williams F; McCall IW; Park WM; O'Connor BT; Morris V
    Clin Radiol; 1981 Jul; 32(4):431-9. PubMed ID: 7249522
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In-111 labeled leukocytes: a review of problems in image interpretation.
    McAfee JG; Samin A
    Radiology; 1985 Apr; 155(1):221-9. PubMed ID: 3919419
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the painful total hip arthroplasty.
    Fisher DA
    Semin Arthroplasty; 1992 Oct; 3(4):229-38. PubMed ID: 10147932
    [TBL] [Abstract][Full Text] [Related]  

  • 19. False-positive 111In-labeled leukocyte scan in cystic fibrosis.
    Crass JR; L'Heureux P; Loken M
    Clin Nucl Med; 1979 Jul; 4(7):291-3. PubMed ID: 466904
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: a prospective study of the prosthetic tip.
    Oswald SG; Van Nostrand D; Savory CG; Callaghan JJ
    J Nucl Med; 1989 Aug; 30(8):1321-31. PubMed ID: 2502609
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.