These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
76 related articles for article (PubMed ID: 3947499)
1. Evaluation of keyed fillers on TEC vaporizers. Richardson W; Carter KB Br J Anaesth; 1986 Mar; 58(3):353-6. PubMed ID: 3947499 [TBL] [Abstract][Full Text] [Related]
2. A new keyed vaporizer filler. Wittmann PH; Wittmann FW; Connor J; Connor T Anaesthesia; 1994 Aug; 49(8):710-2. PubMed ID: 7943705 [TBL] [Abstract][Full Text] [Related]
3. A comparison of keyed and non-keyed vaporizer filling modes and volatile agent wastage. Uncles DR Anaesthesia; 1993 Sep; 48(9):795-8. PubMed ID: 8214502 [TBL] [Abstract][Full Text] [Related]
4. Hypoxic gas mixture delivery due to malfunctioning inlet port of a Select-a-Tec vaporiser manifold. Riendl J Can J Anaesth; 1987 Jul; 34(4):431-2. PubMed ID: 3608070 [No Abstract] [Full Text] [Related]
5. Symposium on anaesthetic equipment. Vaporization and vaporizers. White DC Br J Anaesth; 1985 Jul; 57(7):658-71. PubMed ID: 3893493 [No Abstract] [Full Text] [Related]
9. Sevoflurane vaporizers. Ngan J; Cashen D; Nichols G Can J Anaesth; 1999 Feb; 46(2):200. PubMed ID: 10084008 [No Abstract] [Full Text] [Related]
10. Gas leak due to faulty actuating spindles in a Tec 7 vaporizer. Amagasa S; Takahashi E; Murata N J Anesth; 2014 Dec; 28(6):954. PubMed ID: 24700314 [No Abstract] [Full Text] [Related]
11. Performance of BOC Ohmeda Tec 3 and Tec 4 vaporisers following tipping. Scott DM Anaesth Intensive Care; 1991 Aug; 19(3):441-3. PubMed ID: 1767917 [TBL] [Abstract][Full Text] [Related]
12. Delayed recovery due to a faulty dial lock of a Tec 5 vaporizer. Varshney PG; Taneja B; Saxena KN; Gaba P; Sarin P J Clin Anesth; 2012 Aug; 24(5):434-5. PubMed ID: 22748214 [No Abstract] [Full Text] [Related]
13. Problems with anesthetic gas machines and their solutions. Rendell-Baker L Int Anesthesiol Clin; 1982; 20(3):1-82. PubMed ID: 6215357 [No Abstract] [Full Text] [Related]
14. Ohmeda Tec 5 isoflurane vaporiser and damage to the water trap on the Draeger Primus anaesthesia machine. Reddy S; Bishop SM; Moore JA Anaesthesia; 2008 Aug; 63(8):892-3. PubMed ID: 18699913 [No Abstract] [Full Text] [Related]
15. Long-term performance of Tec vaporizers. Basis for a rational maintenance policy. Carter KB; Gray WM; Railton R; Richardson W Anaesthesia; 1988 Dec; 43(12):1042-6. PubMed ID: 3232782 [TBL] [Abstract][Full Text] [Related]