These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. The accuracy and response characteristics of a simplified ear oximeter. Chapman KR; D'Urzo A; Rebuck AS Chest; 1983 Jun; 83(6):860-4. PubMed ID: 6851688 [TBL] [Abstract][Full Text] [Related]
3. Simultaneous comparison of three noninvasive oximeters in healthy volunteers. Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041 [TBL] [Abstract][Full Text] [Related]
4. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Zeballos RJ; Weisman IM Am Rev Respir Dis; 1991 Dec; 144(6):1240-4. PubMed ID: 1741533 [TBL] [Abstract][Full Text] [Related]
5. Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation. Saunders NA; Powles AC; Rebuck AS Am Rev Respir Dis; 1976 Jun; 113(6):745-9. PubMed ID: 937815 [TBL] [Abstract][Full Text] [Related]
6. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients. Ries AL; Farrow JT; Clausen JL Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542 [TBL] [Abstract][Full Text] [Related]
7. Comparison of three transmittance oximeters. Strohl KP; House PM; Holic JF; Fouke JM; Cheung PW Med Instrum; 1986; 20(3):143-9. PubMed ID: 3724588 [TBL] [Abstract][Full Text] [Related]
8. The accuracy of the Hewlett-Packard 47201A ear oximeter below 50% saturation. Stradling JR Bull Eur Physiopathol Respir; 1982; 18(5):791-4. PubMed ID: 6927531 [TBL] [Abstract][Full Text] [Related]
9. Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100. West P; George CF; Kryger MH Sleep; 1987 Jun; 10(3):263-71. PubMed ID: 3629089 [TBL] [Abstract][Full Text] [Related]
10. Ear oximetry during progressive hypoxia. Gislason T; Sandhagen B; Daskalopouloul E Ups J Med Sci; 1988; 93(1):45-51. PubMed ID: 3376352 [TBL] [Abstract][Full Text] [Related]
11. Accuracy of three pulse oximeters during exercise and hypoxemia in patients with cystic fibrosis. Orenstein DM; Curtis SE; Nixon PA; Hartigan ER Chest; 1993 Oct; 104(4):1187-90. PubMed ID: 8404189 [TBL] [Abstract][Full Text] [Related]
12. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. Feiner JR; Bickler PE; Mannheimer PD Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731 [TBL] [Abstract][Full Text] [Related]
13. Pulse oximetry fails to accurately detect low levels of arterial hemoglobin oxygen saturation in dogs. Sidi A; Rush W; Gravenstein N; Ruiz B; Paulus DA; Davis RF J Clin Monit; 1987 Oct; 3(4):257-62. PubMed ID: 3681359 [TBL] [Abstract][Full Text] [Related]
14. Continuous in vivo measurement of arterial oxygen saturation by oximetry. Flick MR; Block AJ Heart Lung; 1977; 6(6):990-3. PubMed ID: 244328 [TBL] [Abstract][Full Text] [Related]
15. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Bickler PE; Feiner JR; Rollins MD Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027 [TBL] [Abstract][Full Text] [Related]
16. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation. Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666 [TBL] [Abstract][Full Text] [Related]
17. Reliability of six pulse oximeters in chronic obstructive pulmonary disease. Hannhart B; Michalski H; Delorme N; Chapparo G; Polu JM Chest; 1991 Apr; 99(4):842-6. PubMed ID: 2009785 [TBL] [Abstract][Full Text] [Related]