These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 3949968)

  • 1. Techniques and applications of sphenoidal recording.
    King DW; So EL; Marcus R; Gallagher BB
    J Clin Neurophysiol; 1986 Jan; 3(1):51-65. PubMed ID: 3949968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Do sphenoidal electrodes aid in surgical decision making in drug resistant temporal lobe epilepsy?
    Cherian A; Radhakrishnan A; Parameswaran S; Varma R; Radhakrishnan K
    Clin Neurophysiol; 2012 Mar; 123(3):463-70. PubMed ID: 21871835
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of electrical discharges made with the foramen ovale electrode recording technique in mesial temporal lobe epilepsy patients.
    Kim OJ; Ahn JY; Lee BI
    J Clin Neurophysiol; 2004; 21(6):391-8. PubMed ID: 15622124
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Localization of mesial temporal lobe seizures with sphenoidal electrodes.
    Pacia SV; Jung WJ; Devinsky O
    J Clin Neurophysiol; 1998 May; 15(3):256-61. PubMed ID: 9681564
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of coronal sphenoidal versus standard anteroposterior temporal montage in the EEG recording of temporal lobe seizures.
    Ives JR; Drislane FW; Schachter SC; Miles DK; Coots JF; Martin DL; McGuiggan JM; Schomer DL
    Electroencephalogr Clin Neurophysiol; 1996 May; 98(5):417-21. PubMed ID: 8647045
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Can sharp waves localized at the sphenoidal electrode accurately identify a mesio-temporal epileptogenic focus?
    Morris HH; Kanner A; Lüders H; Murphy D; Dinner DS; Wyllie E; Kotagal P
    Epilepsia; 1989; 30(5):532-9. PubMed ID: 2792029
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term ambulatory cassette EEG with sphenoidal recording in complex partial seizures.
    Chu NS
    Epilepsia; 1991; 32(3):351-7. PubMed ID: 2044498
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of sphenoidal, foramen ovale and anterior temporal placements for detecting interictal epileptiform discharges in presurgical assessment for temporal lobe epilepsy.
    Fernández Torre JL; Alarcón G; Binnie CD; Polkey CE
    Clin Neurophysiol; 1999 May; 110(5):895-904. PubMed ID: 10400203
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sensitivity of recordings at sphenoidal electrode site for detecting seizure onset: evidence from scalp, superficial and deep foramen ovale recordings.
    Kissani N; Alarcon G; Dad M; Binnie CD; Polkey CE
    Clin Neurophysiol; 2001 Feb; 112(2):232-40. PubMed ID: 11165524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. "Cavernous sinus EEG": a new method for the preoperative evaluation of temporal lobe epilepsy.
    Mikuni N; Ikeda A; Murao K; Terada K; Nakahara I; Taki W; Kikuchi H; Shibasaki H
    Epilepsia; 1997 Apr; 38(4):472-82. PubMed ID: 9118854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lateralizing and localizing values of ictal onset recorded on the scalp: evidence from simultaneous recordings with intracranial foramen ovale electrodes.
    Alarcón G; Kissani N; Dad M; Elwes RD; Ekanayake J; Hennessy MJ; Koutroumanidis M; Binnie CD; Polkey CE
    Epilepsia; 2001 Nov; 42(11):1426-37. PubMed ID: 11879346
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New topographic mapping of temporal lobe seizures.
    Ives JR; Ichihashi K; Gruber LJ; Mainwaring NR; Blume HW; Schomer DL
    Epilepsia; 1993; 34(5):890-6. PubMed ID: 8404742
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Foramen ovale electrodes can identify a focal seizure onset when surface EEG fails in mesial temporal lobe epilepsy.
    Velasco TR; Sakamoto AC; Alexandre V; Walz R; Dalmagro CL; Bianchin MM; Araújo D; Santos AC; Leite JP; Assirati JA; Carlotti C
    Epilepsia; 2006 Aug; 47(8):1300-7. PubMed ID: 16922874
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The utility of placing sphenoidal electrodes under the foramen ovale with fluoroscopic guidance.
    Kanner AM; Ramirez L; Jones JC
    J Clin Neurophysiol; 1995 Jan; 12(1):72-81. PubMed ID: 7896912
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combined use of sphenoidal electrodes and the dipole localization method for the identification of the mesial temporal focus.
    Yoshinaga H; Hattori J; Nakahori T; Ohtsuka Y; Oka E; Tomita S; Ohmoto T; Miyamoto K
    Eur J Neurol; 2001 Mar; 8(2):149-56. PubMed ID: 11284993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of cavernous sinus EEG in the detection of seizure onset and spread in mesial temporal lobe epilepsy.
    Kunieda T; Ikeda A; Mikuni N; Ohara S; Sadato A; Taki W; Hashimoto N; Shibasaki H
    Epilepsia; 2000 Nov; 41(11):1411-9. PubMed ID: 11077454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison and correlation of surface and sphenoidal electrodes with simultaneous intracranial recording: an interictal study.
    Marks DA; Katz A; Booke J; Spencer DD; Spencer SS
    Electroencephalogr Clin Neurophysiol; 1992 Jan; 82(1):23-9. PubMed ID: 1370140
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Neuronal complexity loss in interictal EEG recorded with foramen ovale electrodes predicts side of primary epileptogenic area in temporal lobe epilepsy: a replication study.
    Weber B; Lehnertz K; Elger CE; Wieser HG
    Epilepsia; 1998 Sep; 39(9):922-7. PubMed ID: 9738671
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The necessity for sphenoidal electrodes in the presurgical evaluation of temporal lobe epilepsy: pro position.
    Sperling MR; Guina L
    J Clin Neurophysiol; 2003; 20(5):299-304. PubMed ID: 14701990
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sphenoidal electrodes: their use and value in the electroencephalographic investigation of complex partial epilepsy.
    Kristensen O; Sindrup EH
    Acta Neurol Scand; 1978 Sep; 58(3):157-66. PubMed ID: 716835
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.