These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
254 related articles for article (PubMed ID: 3950811)
21. Hydroxyapatite impregnated bone cement: in vitro and in vivo studies. Kwon SY; Kim YS; Woo YK; Kim SS; Park JB Biomed Mater Eng; 1997; 7(2):129-40. PubMed ID: 9262826 [TBL] [Abstract][Full Text] [Related]
22. A study of the bioactive bone cement--bone interface: quantitative and histological evaluation. Nishimura N; Taguchi Y; Yamamuro T; Nakamura T; Kokubo T; Yoshihara S J Appl Biomater; 1993; 4(1):29-38. PubMed ID: 10148343 [TBL] [Abstract][Full Text] [Related]
23. Changes in the bone-cement interface after total hip replacement. An in vivo animal study. Radin EL; Rubin CT; Thrasher EL; Lanyon LE; Crugnola AM; Schiller AS; Paul IL; Rose RM J Bone Joint Surg Am; 1982 Oct; 64(8):1188-200. PubMed ID: 7130231 [TBL] [Abstract][Full Text] [Related]
24. Biomechanical properties of bone cement with addition of cefuroxime antibiotic. Mohd Fuad D; Masbah O; Shahril Y; Jamari S; Norhamdan MY; Sahrim SH Med J Malaysia; 2006 Feb; 61 Suppl A():27-9. PubMed ID: 17042225 [TBL] [Abstract][Full Text] [Related]
25. [Chemical and physical properties of Implast, a new bone cement]. Pietsch HG; Seidel H Aktuelle Probl Chir Orthop; 1987; 31():407-13. PubMed ID: 2888396 [No Abstract] [Full Text] [Related]
26. [Blood lamination in bone cement--effect of cementing technique]. Jansson V; Zimmer M; Kühne JH; Ishida A Unfallchirurg; 1993 Jul; 96(7):390-4. PubMed ID: 8367735 [TBL] [Abstract][Full Text] [Related]
27. [Modification of the mechanical properties of bone cements by additives and cement aging in vitro]. Nietert M; Weber U Aktuelle Probl Chir Orthop; 1987; 31():45-50. PubMed ID: 2888402 [No Abstract] [Full Text] [Related]
28. Fatigue properties and stem subsidence in wire coil reinforced PMMA bone cement: a preliminary in vitro study. Kim JK; Park JB Biomed Mater Eng; 1996; 6(6):453-62. PubMed ID: 9138655 [TBL] [Abstract][Full Text] [Related]
29. A fatigue damage model for the cement-bone interface. Kim DG; Miller MA; Mann KA J Biomech; 2004 Oct; 37(10):1505-12. PubMed ID: 15336925 [TBL] [Abstract][Full Text] [Related]
30. The effect of bleeding on the cement-bone interface. An experimental study. Majkowski RS; Bannister GC; Miles AW Clin Orthop Relat Res; 1994 Feb; (299):293-7. PubMed ID: 8119032 [TBL] [Abstract][Full Text] [Related]
31. A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms. Topoleski LD; Ducheyne P; Cuckler JM J Biomed Mater Res; 1990 Feb; 24(2):135-54. PubMed ID: 2329111 [TBL] [Abstract][Full Text] [Related]
32. Mechanical characterization of commercially made carbon-fiber-reinforced polymethylmethacrylate. Saha S; Pal S J Biomed Mater Res; 1986; 20(6):817-26. PubMed ID: 3722216 [TBL] [Abstract][Full Text] [Related]
33. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters. Digas G Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289 [TBL] [Abstract][Full Text] [Related]
34. [Stress-induced structural changes in bone cement--studies of reoperated preparations]. Walde HJ; Rudigier J; Wagner R Aktuelle Probl Chir Orthop; 1987; 31():111-20. PubMed ID: 2888329 [No Abstract] [Full Text] [Related]
35. The mechanical properties of cement and loosening of the femoral component of hip replacements. Weightman B; Freeman MA; Revell PA; Braden M; Albrektsson BE; Carlson LV J Bone Joint Surg Br; 1987 Aug; 69(4):558-64. PubMed ID: 3611159 [TBL] [Abstract][Full Text] [Related]
36. Mechanical properties of bone cement: a review. Saha S; Pal S J Biomed Mater Res; 1984 Apr; 18(4):435-62. PubMed ID: 6376513 [TBL] [Abstract][Full Text] [Related]
37. Methylmethacrylate plasma levels during total hip arthroplasty. Gentil B; Paugam C; Wolf C; Lienhart A; Augereau B Clin Orthop Relat Res; 1993 Feb; (287):112-6. PubMed ID: 8448927 [TBL] [Abstract][Full Text] [Related]
38. Sodium fluoride sustained-release bone cement: an experimental study in vitro and in vivo. Magnan B; Gabbi C; Regis D Acta Orthop Belg; 1994; 60(1):72-9; discussion 80. PubMed ID: 8171990 [TBL] [Abstract][Full Text] [Related]
39. The effect of stem geometry on stresses within the distal cement mantle in total hip replacement. Schmölz W; Gordon DR; Shields AJ; Kirkwood D; Grigoris P Technol Health Care; 2000; 8(1):67-73. PubMed ID: 10942992 [TBL] [Abstract][Full Text] [Related]
40. Bone-particle-impregnated bone cement: an in vitro study. Liu YK; Park JB; Njus GO; Stienstra D J Biomed Mater Res; 1987 Feb; 21(2):247-61. PubMed ID: 3818684 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]