130 related articles for article (PubMed ID: 3951410)
1. Scattered photons produced by beam-modifying filters.
Huang PH; Chin LM; Bjärngard BE
Med Phys; 1986; 13(1):57-63. PubMed ID: 3951410
[TBL] [Abstract][Full Text] [Related]
2. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.
Tsechanski A; Krutman Y; Faermann S
Phys Med Biol; 2005 Dec; 50(23):5629-39. PubMed ID: 16306657
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of the scatter field for high-energy photon beam attenuators.
Castellanos ME; Rosenwald JC
Phys Med Biol; 1998 Feb; 43(2):277-90. PubMed ID: 9509526
[TBL] [Abstract][Full Text] [Related]
4. Inclusion of compensator-induced scatter and beam filtration in pencil beam dose calculations.
du Plessis FC; Willemse CA
Med Phys; 2006 Aug; 33(8):2896-904. PubMed ID: 16964866
[TBL] [Abstract][Full Text] [Related]
5. Head scatter off-axis for megavoltage x rays.
Zhu TC; Bjärngard BE
Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805
[TBL] [Abstract][Full Text] [Related]
6. Field size dependence of wedge factors.
Palta JR; Daftari I; Suntharalingam N
Med Phys; 1988; 15(4):624-6. PubMed ID: 3211058
[TBL] [Abstract][Full Text] [Related]
7. The fraction of photons undergoing head scatter in x-ray beams.
Zhu TC; Bjärngard BE
Phys Med Biol; 1995 Jun; 40(6):1127-34. PubMed ID: 7659734
[TBL] [Abstract][Full Text] [Related]
8. On compensator design for photon beam intensity-modulated conformal therapy.
Jiang SB; Ayyangar KM
Med Phys; 1998 May; 25(5):668-75. PubMed ID: 9608477
[TBL] [Abstract][Full Text] [Related]
9. Scattered photons from wedges in high-energy x-ray beams.
Zhu TC; Bjärngard BE; Vadash P
Med Phys; 1995 Aug; 22(8):1339-42. PubMed ID: 7476722
[TBL] [Abstract][Full Text] [Related]
10. Calculation and measurement of the dose at points outside the primary beam for photon energies of 6, 10, and 23 MV.
van der Giessen PH
Int J Radiat Oncol Biol Phys; 1994 Dec; 30(5):1239-46. PubMed ID: 7961034
[TBL] [Abstract][Full Text] [Related]
11. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
Al-Affan IA
Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
[TBL] [Abstract][Full Text] [Related]
12. Effects of scatter generated by beam-modifying absorbers in megavoltage photon beams.
Islam MK; Van Dyk J
Med Phys; 1995 Dec; 22(12):2075-81. PubMed ID: 8746713
[TBL] [Abstract][Full Text] [Related]
13. Radiological properties of a wax-gypsum compensator material.
du Plessis FC; Willemse CA
Med Phys; 2005 May; 32(5):1246-55. PubMed ID: 15984675
[TBL] [Abstract][Full Text] [Related]
14. Effect of scattering and differential attenuation on beam profile in the presence of high-density intensity modifying compensator.
Kaushik S; Punia R; Tyagi A; Malik A
J Cancer Res Ther; 2019 Mar; 15(Supplement):S110-S114. PubMed ID: 30900631
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of beam hardening and photon scatter by brass compensator for IMRT.
Hashimoto S; Karasawa K; Fujita Y; Miyashita H; Chang W; Kawachi T; Katayose T; Kobayashi N; Kunieda E; Saitoh H
J Radiat Res; 2012 Nov; 53(6):999-1005. PubMed ID: 22915779
[TBL] [Abstract][Full Text] [Related]
16. A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements.
Dalaryd M; Kragl G; Ceberg C; Georg D; McClean B; af Wetterstedt S; Wieslander E; Knöös T
Phys Med Biol; 2010 Dec; 55(23):7333-44. PubMed ID: 21081829
[TBL] [Abstract][Full Text] [Related]
17. Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2007 Mar; 52(6):1595-615. PubMed ID: 17327651
[TBL] [Abstract][Full Text] [Related]
18. A Monte Carlo study on internal wedges using BEAM.
van der Zee W; Welleweerd J
Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
[TBL] [Abstract][Full Text] [Related]
19. Compensators for intensity-modulated beams.
Dimitriadis DM; Fallone BG
Med Dosim; 2002; 27(3):215-20. PubMed ID: 12374378
[TBL] [Abstract][Full Text] [Related]
20. On three-dimensional dose calculation of photon beam with wedge filters.
Yao JY; Ranganathan G
Med Phys; 1994 Jun; 21(6):809-16. PubMed ID: 7935218
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]