191 related articles for article (PubMed ID: 3954583)
1. Suction socket suspension for below-knee amputees.
Roberts RA
Arch Phys Med Rehabil; 1986 Mar; 67(3):196-9. PubMed ID: 3954583
[TBL] [Abstract][Full Text] [Related]
2. Vacuum-assisted socket suspension compared with pin suspension for lower extremity amputees: effect on fit, activity, and limb volume.
Klute GK; Berge JS; Biggs W; Pongnumkul S; Popovic Z; Curless B
Arch Phys Med Rehabil; 2011 Oct; 92(10):1570-5. PubMed ID: 21963124
[TBL] [Abstract][Full Text] [Related]
3. Quantitative and qualitative comparison of a new prosthetic suspension system with two existing suspension systems for lower limb amputees.
Eshraghi A; Abu Osman NA; Karimi MT; Gholizadeh H; Ali S; Wan Abas WA
Am J Phys Med Rehabil; 2012 Dec; 91(12):1028-38. PubMed ID: 23168378
[TBL] [Abstract][Full Text] [Related]
4. A comparison between the suction suspension system and the hypobaric Iceross Seal-In® X5 in transtibial amputees.
Brunelli S; Delussu AS; Paradisi F; Pellegrini R; Traballesi M
Prosthet Orthot Int; 2013 Dec; 37(6):436-44. PubMed ID: 23436696
[TBL] [Abstract][Full Text] [Related]
5. The development and internal consistency of the comprehensive lower limb amputee socket survey in active lower limb amputees.
Gailey R; Kristal A; Lucarevic J; Harris S; Applegate B; Gaunaurd I
Prosthet Orthot Int; 2019 Feb; 43(1):80-87. PubMed ID: 30095355
[TBL] [Abstract][Full Text] [Related]
6. Influence of the scale reduction in designing sockets for trans-tibial amputees.
Dakhil N; Tarrade T; Behr M; Mo F; Evin M; Thefenne L; Liu T; Llari M
Proc Inst Mech Eng H; 2020 Aug; 234(8):761-768. PubMed ID: 32475295
[TBL] [Abstract][Full Text] [Related]
7. Residual limb wounds or ulcers heal in transtibial amputees using an active suction socket system. A randomized controlled study.
Traballesi M; Delussu AS; Fusco A; Iosa M; Averna T; Pellegrini R; Brunelli S
Eur J Phys Rehabil Med; 2012 Dec; 48(4):613-23. PubMed ID: 22641248
[TBL] [Abstract][Full Text] [Related]
8. Alignment of lower-limb prostheses.
Zahedi MS; Spence WD; Solomonidis SE; Paul JP
J Rehabil Res Dev; 1986 Apr; 23(2):2-19. PubMed ID: 3723422
[TBL] [Abstract][Full Text] [Related]
9. Transtibial prosthesis suspension systems: systematic review of literature.
Gholizadeh H; Abu Osman NA; Eshraghi A; Ali S; Razak NA
Clin Biomech (Bristol, Avon); 2014 Jan; 29(1):87-97. PubMed ID: 24315710
[TBL] [Abstract][Full Text] [Related]
10. An open socket technique for through-knee amputations in relation to skin problems of the stump: an explorative study.
Otter N; Postema K; Rijken RA; van Limbeek J
Clin Rehabil; 1999 Feb; 13(1):34-43. PubMed ID: 10327095
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of problems and needs of veteran lower-limb amputees in the San Francisco Bay Area during the period 1977-1980.
Hoaglund FT; Jergesen HE; Wilson L; Lamoreux LW; Roberts R
J Rehabil R D; 1983 Jul; 20(1):57-71. PubMed ID: 6887067
[TBL] [Abstract][Full Text] [Related]
12. Satisfaction and problems experienced with transfemoral suspension systems: a comparison between common suction socket and seal-in liner.
Gholizadeh H; Abu Osman NA; Eshraghi A; Ali S; Yahyavi ES
Arch Phys Med Rehabil; 2013 Aug; 94(8):1584-9. PubMed ID: 23262380
[TBL] [Abstract][Full Text] [Related]
13. Transfemoral prosthesis suspension systems: a systematic review of the literature.
Gholizadeh H; Abu Osman NA; Eshraghi A; Ali S
Am J Phys Med Rehabil; 2014 Sep; 93(9):809-23. PubMed ID: 24743451
[TBL] [Abstract][Full Text] [Related]
14. The TC double socket above-knee prosthesis.
Koike K; Ishikura Y; Kakurai S; Imamura T
Prosthet Orthot Int; 1981 Dec; 5(3):129-34. PubMed ID: 7329773
[TBL] [Abstract][Full Text] [Related]
15. Comparing preference of ankle-foot stiffness in below-knee amputees and prosthetists.
Shepherd MK; Rouse EJ
Sci Rep; 2020 Sep; 10(1):16067. PubMed ID: 32999317
[TBL] [Abstract][Full Text] [Related]
16. Prescription options for the below knee amputee. A review.
Abrahamson MA; Skinner HB; Effeney DJ; Wilson LA
Orthopedics; 1985 Feb; 8(2):210-20. PubMed ID: 4094970
[TBL] [Abstract][Full Text] [Related]
17. Temporary prosthetic fitting for below-knee amputation.
Ozyalcin H; Sesli E
Prosthet Orthot Int; 1989 Aug; 13(2):86-9. PubMed ID: 2780266
[TBL] [Abstract][Full Text] [Related]
18. Axial bone-socket displacement for persons with a traumatic transtibial amputation: The effect of elevated vacuum suspension at progressive body-weight loads.
Darter BJ; Sinitski K; Wilken JM
Prosthet Orthot Int; 2016 Oct; 40(5):552-7. PubMed ID: 26423107
[TBL] [Abstract][Full Text] [Related]
19. Acroangiodermatitis in a leg amputee using a suction-socket prosthesis: clinical, histological as well as HHV-8 and CD34 immunohistochemical study.
Pietkiewicz P; Bowszyc-Dmochowska M; Gornowicz-Porowska J; Majewski P; Marszałek A; Dmochowski M
Pol J Pathol; 2013 Jun; 64(2):153-6. PubMed ID: 23900875
[TBL] [Abstract][Full Text] [Related]
20. The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance.
Gholizadeh H; Abu Osman NA; Eshraghi A; Ali S
PLoS One; 2014; 9(5):e94520. PubMed ID: 24827560
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]