These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

311 related articles for article (PubMed ID: 396327)

  • 1. [Studies on the accuracy of elastomeric impression materials. Part 2. Comparison of dimensional accuracy of casts made by both single polyether rubber impression and the combined reversible and irreversible hydrocolloid impression technique (author's transl)].
    Shigeto N; Inohara N; Yamada S
    Hiroshima Daigaku Shigaku Zasshi; 1978; 10(1):98-108. PubMed ID: 396327
    [No Abstract]   [Full Text] [Related]  

  • 2. Dimensional accuracy of dental casts: influence of tray material, impression material, and time.
    Thongthammachat S; Moore BK; Barco MT; Hovijitra S; Brown DT; Andres CJ
    J Prosthodont; 2002 Jun; 11(2):98-108. PubMed ID: 12087547
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of the type and technique used for impression making on the accuracy of elastomeric impression materials.
    Habib AN; Shehata MT
    Egypt Dent J; 1995 Oct; 41(4):1409-16. PubMed ID: 9497690
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinically oriented evaluation of the accuracy of commonly used impression materials.
    Tjan AH; Whang SB; Tjan AH; Sarkissian R
    J Prosthet Dent; 1986 Jul; 56(1):4-8. PubMed ID: 3522878
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of accuracy and the time-dependent dimensional stability of silicone based impression materials].
    Yavuzyilmaz H; Dinçer C; Nalbant L
    Ankara Univ Hekim Fak Derg; 1989 Sep; 16(3):425-8. PubMed ID: 2489491
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of water temperature on the accuracy of stone casts recovered from addition-reaction elastomeric impression materials.
    Saunders WP; Sharkey SW; Smith GM
    Int J Prosthodont; 1990; 3(6):577-81. PubMed ID: 2083027
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of storage time on the accuracy and dimensional stability of reversible hydrocolloid impression material.
    Schleier PE; Gardner FM; Nelson SK; Pashley DH
    J Prosthet Dent; 2001 Sep; 86(3):244-50. PubMed ID: 11552162
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Studies on the dimensional accuracy of complete dental arch casts, especially on the effects of various methods of taking impressions ((author's transl)].
    Shigeto N
    Hiroshima Daigaku Shigaku Zasshi; 1981 Dec; 13(2):197-216. PubMed ID: 7045201
    [No Abstract]   [Full Text] [Related]  

  • 9. Pre- and post-set hydrophilicity of elastomeric impression materials.
    Michalakis KX; Bakopoulou A; Hirayama H; Garefis DP; Garefis PD
    J Prosthodont; 2007; 16(4):238-48. PubMed ID: 17559537
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of dimensional accuracy between three different addition cured silicone impression materials.
    Forrester-Baker L; Seymour KG; Samarawickrama D; Zou L; Cherukara G; Patel M
    Eur J Prosthodont Restor Dent; 2005 Jun; 13(2):69-74. PubMed ID: 16011234
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The dimensional accuracy of four impression techniques with the use of addition silicone impression materials.
    Al-Bakri IA; Hussey D; Al-Omari WM
    J Clin Dent; 2007; 18(2):29-33. PubMed ID: 17508620
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of dimensional stability of elastomeric impression materials during disinfection.
    Oda Y; Matsumoto T; Sumii T
    Bull Tokyo Dent Coll; 1995 Feb; 36(1):1-7. PubMed ID: 8689737
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Studies on dimensional accuracy of indirect working model in fixed partial dentures--laminated reversible and irreversible hydrocolloid impression method (author's transl)].
    Yawata S
    Shigaku; 1978 Apr; 65(6):1074-85. PubMed ID: 397426
    [No Abstract]   [Full Text] [Related]  

  • 14. [Dimensional changes of stone models made by the laminated single impression technique with silicone materials (author's transl)].
    Kurosaki N; Takatsu T; Kezuka K; Kuroiwa S; Yokoyama H
    Nihon Shika Zairyo Kikai Gakkai Zasshi; 1974 Jun; 31(2):21-6. PubMed ID: 4620679
    [No Abstract]   [Full Text] [Related]  

  • 15. Dimensional accuracy of 3 silicone dental impression materials.
    Hassan AK
    East Mediterr Health J; 2006 Sep; 12(5):632-6. PubMed ID: 17333804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of complete dental arch impressions and stone casts using a three-dimensional measurement system. Effects on accuracy of rubber impression materials and trays.
    Ishida K
    Dent Jpn (Tokyo); 1990; 27(1):73-9. PubMed ID: 2099294
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Using reversible hydrocolloid impression materials.
    Wartell RL
    Compend Contin Educ Dent (Lawrenceville); 1984 Mar; 5(3):229-32, 235-8. PubMed ID: 6380925
    [No Abstract]   [Full Text] [Related]  

  • 18. [Disinfection of dental impressions].
    Setz J; Heeg P
    Dtsch Zahnarztl Z; 1991 Mar; 46(3):186-8. PubMed ID: 1814718
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Surfaces of stone models made by the laminated single impression technique with silicone materials (author's transl)].
    Daito K; Miyauchi H; Okuno T; Mitani S; Takatsu T
    Nihon Shika Zairyo Kikai Gakkai Zasshi; 1974 Jun; 31(2):27-31. PubMed ID: 4620680
    [No Abstract]   [Full Text] [Related]  

  • 20. Factors affecting the accuracy of elastometric impression materials.
    Chen SY; Liang WM; Chen FN
    J Dent; 2004 Nov; 32(8):603-9. PubMed ID: 15476954
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.