133 related articles for article (PubMed ID: 3965221)
1. New test for urinary glucose (BM33071) evaluated.
Smalley DL; Bradley ME
Clin Chem; 1985 Jan; 31(1):90-2. PubMed ID: 3965221
[TBL] [Abstract][Full Text] [Related]
2. Ascorbic acid interference in reagent-strip reactions for assay of urinary glucose and hemoglobin.
Zweig MH; Jackson A
Clin Chem; 1986 Apr; 32(4):674-7. PubMed ID: 3955816
[TBL] [Abstract][Full Text] [Related]
3. Ascorbate interference in the estimation of urinary glucose by test strips.
Berg B
J Clin Chem Clin Biochem; 1986 Jan; 24(1):89-96. PubMed ID: 3701272
[TBL] [Abstract][Full Text] [Related]
4. False-negative tests for urine glucose.
Mayson JS; Schumaker O; Nakamura RM
Lancet; 1973 Apr; 1(7806):780-1. PubMed ID: 4120767
[No Abstract] [Full Text] [Related]
5. [Interference of ascorbic acid in the measurement of glucose concentration in urine by means of strips and quantitative methods].
Nielsen L; Jørgensen PJ; Hansen AC
Ugeskr Laeger; 1979 Mar; 141(12):791-3. PubMed ID: 425173
[No Abstract] [Full Text] [Related]
6. [Detection of urinary glucose with the glucose oxidase method (strip test)].
Burlina A
Minerva Med; 1967 Dec; 58(100):4622-5. PubMed ID: 6081727
[No Abstract] [Full Text] [Related]
7. [Interference by ascorbic acid in glucose determination by reagent strip].
Kohl H
Ric Clin Lab; 1978; 8 Suppl 2():75-80. PubMed ID: 746302
[No Abstract] [Full Text] [Related]
8. Interference with dipstick tests for glucose and hemoglobin in urine by ascorbic acid in cranberry juice.
Kilbourn JP
Clin Chem; 1987 Jul; 33(7):1297. PubMed ID: 3594894
[No Abstract] [Full Text] [Related]
9. Effect of ketones and glucose on the estimation of urinary creatinine: implications for microalbuminuria screening.
Watts GF; Pillay D
Diabet Med; 1990; 7(3):263-5. PubMed ID: 2139401
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of some commonly used semiquantitative methods for urinary glucose and ketone determinations.
James RC; Chase GR
Diabetes; 1974 May; 23(5):474-9. PubMed ID: 4830183
[No Abstract] [Full Text] [Related]
11. [Diabur-Test 5000 - a new test strip for urinary sugar control in diabetic patients (author's transl)].
Kattermann R; Frey HO; Ballies U; Kutter D; von Oudheusden AP; von Buul T; Klein HJ; Forster E; Banauch D; Koller PU
Dtsch Med Wochenschr; 1982 Jan; 107(3):97-100. PubMed ID: 7056164
[TBL] [Abstract][Full Text] [Related]
12. Urinalysis by use of multi-test reagent strips: two dipsticks compared.
Smith BC; Peake MJ; Fraser CG
Clin Chem; 1977 Dec; 23(12):2337-40. PubMed ID: 923084
[TBL] [Abstract][Full Text] [Related]
13. [Precision of test strip diagnosis].
Jagenburg R
Lakartidningen; 1980 Apr; 77(15):1413-5. PubMed ID: 7382657
[No Abstract] [Full Text] [Related]
14. [Summary of aspects and recommendations for detection of urine components with test strips].
Fritz H; Jagenburg R; Tibbling G
Lakartidningen; 1980 Apr; 77(15):1416-8. PubMed ID: 7382658
[No Abstract] [Full Text] [Related]
15. [Urine glucose monitoring at home becomes easier and more precise with a new test-tape: diabur-test 5000 (author's transl)].
Hasala M; Weber B
Monatsschr Kinderheilkd; 1982 Apr; 130(4):218-20. PubMed ID: 7099175
[TBL] [Abstract][Full Text] [Related]
16. [Clinical value of ascorbic acid disorders in determining glucose and erythrocytes on urine test strips].
Seiler D; Jeppsson JO; Nagel D; Kristensen HH; Jacobsen HJ; Daae L; Tritschler W; Willamowski KD
Med Lab (Stuttg); 1981 Dec; 34(12):327-30. PubMed ID: 7346708
[No Abstract] [Full Text] [Related]
17. [Semi-quantitative determination of urinary glucose by means of reactive paper strips. Comparative study].
Abayomi O; Barbería Layana JJ; Moncada Lorenzo E
Rev Med Univ Navarra; 1972 Jun; 16(2):191-4. PubMed ID: 4643590
[No Abstract] [Full Text] [Related]
18. [Development of methods for the qualitative and quantitative determination of urinary glucose].
Pöge AW; Dieterich F; Hellthaler G; Estay N; de Morena E
Z Gesamte Inn Med; 1981 Nov; 36(22):881-4. PubMed ID: 7342511
[TBL] [Abstract][Full Text] [Related]
19. [Determination of urinary glucose. Simple determination of urinary glucose with a new semi-quantitative reagent stick; the Diabur Test 5000].
Dahl-Jørgensen K; Hanssen KF; Aagenaes O; Haider T
Tidsskr Nor Laegeforen; 1984 Sep; 104(26):1803-6. PubMed ID: 6495272
[No Abstract] [Full Text] [Related]
20. [Urine analysis using paper reagent strips. Comparison with conventional chemical analysis].
Demol R; Brassinne A
Rev Med Liege; 1980 Feb; 35(4):118-21. PubMed ID: 7361021
[No Abstract] [Full Text] [Related]
[Next] [New Search]