These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
123 related articles for article (PubMed ID: 3965247)
1. Single-breath measurement of lung mechanics in very low birth weight infants. Thomson A; Silverman M Crit Care Med; 1985 Jan; 13(1):4-8. PubMed ID: 3965247 [TBL] [Abstract][Full Text] [Related]
2. Passive respiratory mechanics in newborns and children. Lesouef PN; England SJ; Bryan AC Am Rev Respir Dis; 1984 Apr; 129(4):552-6. PubMed ID: 6711998 [TBL] [Abstract][Full Text] [Related]
3. Rapid improvement of static compliance after surfactant treatment in preterm infants with respiratory distress syndrome. Baraldi E; Pettenazzo A; Filippone M; Magagnin GP; Saia OS; Zacchello F Pediatr Pulmonol; 1993 Mar; 15(3):157-62. PubMed ID: 8327278 [TBL] [Abstract][Full Text] [Related]
4. Birth weight and early lung compliance as predictors of short-term outcome in premature infants with respiratory distress syndrome. Smith J; van Lierde S; Devlieger H; Daniels H; Eggermont E S Afr Med J; 1995 Nov; 85(11):1157-60. PubMed ID: 8597004 [TBL] [Abstract][Full Text] [Related]
5. Comparison of dynamic and passive measurements of respiratory mechanics in ventilated newborn infants. Kugelman A; Keens TG; deLemos R; Durand M Pediatr Pulmonol; 1995 Oct; 20(4):258-64. PubMed ID: 8606856 [TBL] [Abstract][Full Text] [Related]
6. Compliance of the respiratory system as a predictor for successful extubation in very-low-birth-weight infants recovering from respiratory distress syndrome. Smith J; Pieper CH; Maree D; Gie RP S Afr Med J; 1999 Oct; 89(10):1097-102. PubMed ID: 10582068 [TBL] [Abstract][Full Text] [Related]
7. Respiratory mechanics in mechanically ventilated newborns: a comparison between passive inflation and occlusion methods. Storme L; Riou Y; Leclerc F; Kacet N; Dubos JP; Gremillet C; Rousseau S; Lequien P Pediatr Pulmonol; 1992 Apr; 12(4):203-12. PubMed ID: 1614746 [TBL] [Abstract][Full Text] [Related]
8. Lung volume, gas mixing, and mechanics of breathing in mechanically ventilated very low birth weight infants with idiopathic respiratory distress syndrome. Edberg KE; Sandberg K; Silberberg A; Ekström-Jodal B; Hjalmarson O Pediatr Res; 1991 Nov; 30(5):496-500. PubMed ID: 1754308 [TBL] [Abstract][Full Text] [Related]
9. Differential effects of immaturity and neonatal lung disease on the lung function of very low birth weight infants at 48-52 postconceptional weeks. Schmalisch G; Wilitzki S; Roehr CC; Proquitté H; Bührer C Pediatr Pulmonol; 2013 Dec; 48(12):1214-23. PubMed ID: 23401477 [TBL] [Abstract][Full Text] [Related]
10. Successful extubation of neonates: clinical and physiological factors. Fox WW; Schwartz JG; Shaffer TH Crit Care Med; 1981 Dec; 9(12):823-6. PubMed ID: 7318452 [TBL] [Abstract][Full Text] [Related]
11. Effect of forced deflation maneuvers upon measurements of respiratory mechanics in ventilated infants. Hammer J; Patel N; Newth CJ Intensive Care Med; 2003 Nov; 29(11):2004-8. PubMed ID: 12897998 [TBL] [Abstract][Full Text] [Related]
12. Measurements of pulmonary mechanics prior to the elective extubation of neonates. Balsan MJ; Jones JG; Watchko JF; Guthrie RD Pediatr Pulmonol; 1990; 9(4):238-43. PubMed ID: 2259556 [TBL] [Abstract][Full Text] [Related]
13. Relationship between respiratory impedance and positive end-expiratory pressure in mechanically ventilated neonates. Dellacà RL; Veneroni C; Vendettuoli V; Zannin E; Matassa PG; Pedotti A; Colnaghi M; Mosca F Intensive Care Med; 2013 Mar; 39(3):511-9. PubMed ID: 23306585 [TBL] [Abstract][Full Text] [Related]
14. Immediate effects on lung function of instilled human surfactant in mechanically ventilated newborn infants with IRDS. Edberg KE; Ekström-Jodal B; Hallman M; Hjalmarson O; Sandberg K; Silberberg A Acta Paediatr Scand; 1990; 79(8-9):750-5. PubMed ID: 2239268 [TBL] [Abstract][Full Text] [Related]
15. Paralysis of ventilated newborn babies does not influence resistance of the total respiratory system. Burger R; Fanconi S; Simma B Eur Respir J; 1999 Aug; 14(2):357-62. PubMed ID: 10515414 [TBL] [Abstract][Full Text] [Related]
16. Pulmonary compliance in sick low birthweight infants. How reliable is the measurement of oesophageal pressure? Thomson A; Elliott J; Silverman M Arch Dis Child; 1983 Nov; 58(11):891-6. PubMed ID: 6651326 [TBL] [Abstract][Full Text] [Related]
17. Pulmonary mechanics in infants after cardiac surgery. DiCarlo JV; Raphaely RC; Steven JM; Norwood WI; Costarino AT Crit Care Med; 1992 Jan; 20(1):22-7. PubMed ID: 1729039 [TBL] [Abstract][Full Text] [Related]
18. Comparison of dynamic and static measurements of respiratory mechanics in infants. Gerhardt T; Reifenberg L; Duara S; Bancalari E J Pediatr; 1989 Jan; 114(1):120-5. PubMed ID: 2909696 [TBL] [Abstract][Full Text] [Related]
19. High-frequency oscillatory ventilation compared with conventional mechanical ventilation in the treatment of respiratory failure in preterm infants: assessment of pulmonary function at 9 months of corrected age. HiFi Study Group. J Pediatr; 1990 Jun; 116(6):933-41. PubMed ID: 2112188 [TBL] [Abstract][Full Text] [Related]
20. Use of external expiratory resistance in intubated neonates to increase lung volume. Moomjian AS; Schwartz JG; Shutack JG; Rooklin AR; Shaffer TH; Fox WW Arch Dis Child; 1981 Nov; 56(11):869-73. PubMed ID: 7305430 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]