131 related articles for article (PubMed ID: 3966349)
1. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output.
Labovitz AJ; Buckingham TA; Habermehl K; Nelson J; Kennedy HL; Williams GA
Am Heart J; 1985 Feb; 109(2):327-32. PubMed ID: 3966349
[TBL] [Abstract][Full Text] [Related]
2. Pulsed Doppler transesophageal echocardiographic determination of cardiac output in human beings: comparison with thermodilution technique.
Stoddard MF; Prince CR; Ammash N; Goad JL; Vogel RL
Am Heart J; 1993 Oct; 126(4):956-62. PubMed ID: 8213455
[TBL] [Abstract][Full Text] [Related]
3. Measurement of left ventricular stroke volume using continuous wave Doppler echocardiography of the ascending aorta and M-mode echocardiography of the aortic valve.
Bouchard A; Blumlein S; Schiller NB; Schlitt S; Byrd BF; Ports T; Chatterjee K
J Am Coll Cardiol; 1987 Jan; 9(1):75-83. PubMed ID: 3794113
[TBL] [Abstract][Full Text] [Related]
4. Automatic cardiac output measurement (ACOM): clinical applications of a new noninvasive tool.
Trindade PT; Brown P; Puryear JV; Popylisen S; Schnittger I
Int J Card Imaging; 1998 Jun; 14(3):147-54. PubMed ID: 9813750
[TBL] [Abstract][Full Text] [Related]
5. Noninvasive maternal stroke volume and cardiac output determinations by pulsed Doppler echocardiography.
Lee W; Rokey R; Cotton DB
Am J Obstet Gynecol; 1988 Mar; 158(3 Pt 1):505-10. PubMed ID: 3348311
[TBL] [Abstract][Full Text] [Related]
6. Cardiac index quantification by Doppler ultrasound in patients without left ventricular outflow tract abnormalities.
Evangelista A; Garcia-Dorado D; Garcia del Castillo H; Gonzalez-Alujas T; Soler-Soler J
J Am Coll Cardiol; 1995 Mar; 25(3):710-6. PubMed ID: 7860918
[TBL] [Abstract][Full Text] [Related]
7. An enhanced method for measuring cardiac output using Doppler color flow echocardiography.
Seo H; Yamagishi M; Haque SA; Mohibullah AK; Majumder A al-S ; Nakatani S; Kwan OL; DeMaria AN; Miyatake K
Jpn Circ J; 1997 Nov; 61(11):905-11. PubMed ID: 9391857
[TBL] [Abstract][Full Text] [Related]
8. Superiority of two-dimensional measurement of aortic vessel diameter in Doppler echocardiographic estimates of left ventricular stroke volume.
Gardin JM; Tobis JM; Dabestani A; Smith C; Elkayam U; Castleman E; White D; Allfie A; Henry WL
J Am Coll Cardiol; 1985 Jul; 6(1):66-74. PubMed ID: 4008789
[TBL] [Abstract][Full Text] [Related]
9. Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution.
Christie J; Sheldahl LM; Tristani FE; Sagar KB; Ptacin MJ; Wann S
Circulation; 1987 Sep; 76(3):539-47. PubMed ID: 3621519
[TBL] [Abstract][Full Text] [Related]
10. Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography.
Dittmann H; Voelker W; Karsch KR; Seipel L
J Am Coll Cardiol; 1987 Oct; 10(4):818-23. PubMed ID: 3655148
[TBL] [Abstract][Full Text] [Related]
11. Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution.
Blissitt KJ; Young LE; Jones RS; Darke PG; Utting J
Equine Vet J; 1997 Jan; 29(1):18-25. PubMed ID: 9031859
[TBL] [Abstract][Full Text] [Related]
12. Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes.
Fratacci MD; Payen D; Beloucif S; Laborde F
Chest; 1992 Aug; 102(2):380-6. PubMed ID: 1643918
[TBL] [Abstract][Full Text] [Related]
13. Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with thermodilution in cardiac surgery.
Parra V; Fita G; Rovira I; Matute P; Gomar C; Paré C
Eur J Anaesthesiol; 2008 Feb; 25(2):135-43. PubMed ID: 17672920
[TBL] [Abstract][Full Text] [Related]
14. Transgastric, pulsed Doppler echocardiographic determination of cardiac output.
Descorps-Declere A; Smail N; Vigue B; Duranteau J; Mimoz O; Edouard A; Samii K
Intensive Care Med; 1996 Jan; 22(1):34-8. PubMed ID: 8857435
[TBL] [Abstract][Full Text] [Related]
15. Cardiac output measurements during cross-clamping of the descending thoracic aorta in pigs. A comparison between transit-time ultrasound, thermodilution and pulsed Doppler ultrasound.
Aadahl P; Aakhus S; Saether OD; Stømholm T; Myhre HO
Acta Anaesthesiol Scand; 2000 Feb; 44(2):180-5. PubMed ID: 10695912
[TBL] [Abstract][Full Text] [Related]
16. [Comparison of Doppler echocardiographic methods of determining cardiac minute volume].
Dittmann H; Voelker W; Karsch KR; Seipel L
Z Kardiol; 1987 Jul; 76(7):433-8. PubMed ID: 3673165
[TBL] [Abstract][Full Text] [Related]
17. Pulsed Doppler ultrasound compared with thermodilution for monitoring cardiac output responses to changing left ventricular function.
Bojanowski LM; Timmis AD; Najm YC; Gosling RG
Cardiovasc Res; 1987 Apr; 21(4):260-8. PubMed ID: 3652093
[TBL] [Abstract][Full Text] [Related]
18. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution.
Mellander M; Sabel KG; Caidahl K; Solymar L; Eriksson B
Pediatr Cardiol; 1987; 8(4):241-6. PubMed ID: 3432113
[TBL] [Abstract][Full Text] [Related]
19. Validation of cardiac output measurements with noninvasive Doppler echocardiography by thermodilution and Fick methods in newborn piglets.
Welch E; Duara S; Suguihara C; Bandstra E; Bancalari E
Biol Neonate; 1994; 66(2-3):137-45. PubMed ID: 7993947
[TBL] [Abstract][Full Text] [Related]
20. Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature.
Nishimura RA; Callahan MJ; Schaff HV; Ilstrup DM; Miller FA; Tajik AJ
Mayo Clin Proc; 1984 Jul; 59(7):484-9. PubMed ID: 6738114
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]