BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 3971578)

  • 1. The Abbott TDx fluorescence polarization immunoassay and liquid chromatography compared for five anticonvulsant drugs in serum.
    Wang ST; Peter F
    Clin Chem; 1985 Mar; 31(3):493-4. PubMed ID: 3971578
    [No Abstract]   [Full Text] [Related]  

  • 2. Evaluation of the Abbott TDx for the stat measurement of phenobarbital, phenytoin, carbamazepine, and theophylline.
    Loomis KF; Frye RM
    Am J Clin Pathol; 1983 Nov; 80(5):686-91. PubMed ID: 6637881
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated homogeneous liposome immunoassay systems for anticonvulsant drugs.
    Kubotsu K; Goto S; Fujita M; Tuchiya H; Kida M; Takano S; Matsuura S; Sakurabayashi I
    Clin Chem; 1992 Jun; 38(6):808-12. PubMed ID: 1597006
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of fluorescence polarization immunoassay and high performance liquid chromatography for the quantitative determination of phenytoin, phenobarbitone and carbamazepine in serum.
    Ashy AR; el-Sayed YM; Islam SI
    J Pharm Pharmacol; 1986 Aug; 38(8):572-7. PubMed ID: 2876072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of a new serum topiramate immunoassay to fluorescence polarization immunoassay.
    Snozek CL; Rollins LA; Peterson PW; Langman LJ
    Ther Drug Monit; 2010 Feb; 32(1):107-11. PubMed ID: 20010458
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of monitoring the efficacy of phenobarbital as an anticonvulsant agents using the fluorescence-polarization immunoassay].
    Karamehić J; Tulumović T; Uzeirbegović M; Trnovcević J; Asćerić M; Hadzibegić N
    Med Arh; 1998; 52(2):65-6. PubMed ID: 9769637
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of TDx cocaine metabolite assay.
    Poklis A
    J Anal Toxicol; 1987; 11(5):228-30. PubMed ID: 3682784
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phenytoin free fraction determination: comparison of an improved direct serum injection high-performance liquid chromatographic method to ultrafiltration coupled with fluorescence polarization immunoassay.
    Gurley BJ; Marx M; Olsen K
    J Chromatogr B Biomed Appl; 1995 Aug; 670(2):358-64. PubMed ID: 8548029
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of serum acetaminophen in emergency toxicology: evaluation of newer methods: Abbott TDx and second derivative ultraviolet spectrophotometry.
    Edinboro LE; Jackson GF; Jortani SA; Poklis A
    J Toxicol Clin Toxicol; 1991; 29(2):241-55. PubMed ID: 2051511
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of an automated extractor/concentrator to the analysis of anticonvulsant drugs in blood serum by high-performance liquid chromatography.
    Williams RC; Viola JL
    J Chromatogr; 1979 Dec; 185():505-13. PubMed ID: 546932
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Methotrexate measurements in plasma: comparison of enzyme multiplied immunoassay technique, TDx fluorescence polarization immunoassay, and high pressure liquid chromatography.
    Slørdal L; Prytz PS; Pettersen I; Aarbakke J
    Ther Drug Monit; 1986; 8(3):368-72. PubMed ID: 3529519
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preliminary evaluation of a fluorescence polarization immunoassay (Abbott TDx) for estimating serum free thyroxine concentrations in patients with critical nonthyroid illness and low total thyroxine concentrations in serum.
    Mendel CM
    Clin Chem; 1992 Sep; 38(9):1916-7. PubMed ID: 1526035
    [No Abstract]   [Full Text] [Related]  

  • 13. Particle counting immunoassay for urinary cotinine. Comparison with chromatography, enzyme-linked immunoassay and fluorescence polarization immunoassay.
    Galanti LM; Dell'Omo J; Vanbeckbergen D; Dubois P; Masson PL; Cambiaso CL
    Clin Chem Lab Med; 1999 Jul; 37(7):729-34. PubMed ID: 10510730
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of lidocaine by fluorescence polarization immunoassay, enzyme immunoassay, and high resolution gas chromatography.
    Bertol E; Mari F; Torracca F
    J Anal Toxicol; 1987; 11(3):122-4. PubMed ID: 3298856
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the Abbott IMx fluorescence polarization immunoassay and the bio-rad enzyme immunoassay for homocysteine: comparison with high-performance liquid chromatography.
    Donnelly JG; Pronovost C
    Ann Clin Biochem; 2000 Mar; 37 ( Pt 2)():194-8. PubMed ID: 10735363
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of serum hydroquinidine determination by fluorescence polarization immunoassay and liquid chromatography.
    Tod M; Resplandy G; Farinotti R; Provost Y; Dauphin A
    J Pharm Biomed Anal; 1990; 8(3):279-82. PubMed ID: 2094427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved liquid chromatographic/immunoassay of digoxin in serum.
    Stone JA; Soldin SJ
    Clin Chem; 1988 Dec; 34(12):2547-51. PubMed ID: 3197300
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative evaluation of the Abbott TDX, the Abbott ABA200, and the Syva LAB5000 for assay of serum gentamicin.
    Cheng AF; Lam AW; French GL
    J Antimicrob Chemother; 1987 Jan; 19(1):127-33. PubMed ID: 3549667
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Abbott's fluorescence polarization immunoassay for cyclosporine and metabolites compared with the Sandoz "Sandimmune" RIA.
    Sanghvi A; Diven W; Seltman H; Starzl T
    Clin Chem; 1988 Sep; 34(9):1904-6. PubMed ID: 3416444
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurements of serum gentamicin concentrations by a biological method, fluorescence polarization immunoassay and enzyme multiplied immunoassay.
    Araj GF; Khattar MA; Thulesius O; Pazhoor A
    Int J Clin Pharmacol Ther Toxicol; 1986 Oct; 24(10):542-5. PubMed ID: 3536762
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.