217 related articles for article (PubMed ID: 397488)
1. [Insulin therapy by subcutaneous infusion using a portable pump. A simple method to stabilize brittle diabetics (author's transl)].
Berger W; Schwarz U; Kaegi E; Keller U; Viollier E
Schweiz Rundsch Med Prax; 1979 Dec; 68(49):1620-9. PubMed ID: 397488
[No Abstract] [Full Text] [Related]
2. [Diabetic control with a portable insulin infusion pump for 7 weeks (author's transl)].
Irsigler K; Kritz H; Koller W; Kaspar L; Mader R; Franetzki M
Med Klin; 1978 Dec; 73(49):1738-43. PubMed ID: 723761
[TBL] [Abstract][Full Text] [Related]
3. [Clinical use of insulin infusions using the open-loop system].
Irsigler K; Kritz H
Z Gesamte Inn Med; 1981 Jan; 36(1):8-19. PubMed ID: 7013294
[TBL] [Abstract][Full Text] [Related]
4. [Maintenance of normoglycemia in diabetics with continuous subcutaneous insulin infusion: a real therapeutical need? (author's transl)].
Studer PP; Berger W
Schweiz Rundsch Med Prax; 1981 Jan; 70(5):137-9. PubMed ID: 6782563
[No Abstract] [Full Text] [Related]
5. [Juvenile diabetes of recent onset. Sustained insulin remission by means of preprogrammed insulin infusion (author's transl)].
Pinget M; Blickle JF; Anceau A; Audhuy B; Jacques C; Brogard JM; Dorner M
Nouv Presse Med; 1981 Apr; 10(17):1381-4. PubMed ID: 7015270
[TBL] [Abstract][Full Text] [Related]
6. Technology of pre-programmable insulin delivery systems: continuous subcutaneous insulin infusion.
Pickup JC; Keen H; Parsons JA; Alberti KG
Horm Metab Res Suppl; 1979; (8):49-51. PubMed ID: 395089
[TBL] [Abstract][Full Text] [Related]
7. Insulin infusion via a portable pump.
Orzeck EA
Tex Med; 1980 Jul; 76(7):46-9. PubMed ID: 6994269
[No Abstract] [Full Text] [Related]
8. Clinical application of pre-programmed insulin infusion: continuous subcutaneous insulin therapy with a portable infusion system.
Pickup JC; Viberti GC; Keen H; Parsons JA; Alberti KG
Horm Metab Res Suppl; 1979; (8):202-4. PubMed ID: 395081
[TBL] [Abstract][Full Text] [Related]
9. Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump.
Tamborlane WV; Sherwin RS; Genel M; Felig P
N Engl J Med; 1979 Mar; 300(11):573-8. PubMed ID: 763270
[TBL] [Abstract][Full Text] [Related]
10. [The treatment of diabetes mellitus using continuous subcutaneous infusion].
van Ballegooie E; Sluiter WJ; Reitsma WD; Doorenbos H
Ned Tijdschr Geneeskd; 1980 Nov; 124(48):2038-42. PubMed ID: 7003403
[No Abstract] [Full Text] [Related]
11. [Diabetes therapy with continuous insulin infusion by a portable pump: metabolic effects of short-term treatment and long-term results in problem patients].
Schernthaner G; Graninger W; Kwasny W; Prager R; Otto C
Acta Med Austriaca; 1982; 9(5-6):205-13. PubMed ID: 6762034
[TBL] [Abstract][Full Text] [Related]
12. [Subcutaneous infusion of insulin in diabetics: clinical results].
Pickup JC; Keen H; White MC; Kohner EM; Parsons JA; Alberti KG
Journ Annu Diabetol Hotel Dieu; 1980 May; ():17-22. PubMed ID: 6995668
[No Abstract] [Full Text] [Related]
13. A portable, pre-programmable insulin infusion system in diabetes mellitus.
Kølendorf K; Bojsen J
Horm Metab Res Suppl; 1979; (8):191-3. PubMed ID: 395078
[TBL] [Abstract][Full Text] [Related]
14. [Artificial endocrine pancreas (author's transl)].
Kruse-Jarres JD
J Clin Chem Clin Biochem; 1979 Jul; 17(7):457-63. PubMed ID: 383880
[TBL] [Abstract][Full Text] [Related]
15. [Continuous predetermined insulin infusion in insulin-dependent diabetes mellitus (author's transl)].
Jean R; Rolin B
Sem Hop; 1982 Jan; 58(2):123-6. PubMed ID: 6276997
[TBL] [Abstract][Full Text] [Related]
16. Optimal blood sugar control in labile diabetics using a portable open-loop insulin infusion system with a flexible program.
Froesch ER; Blatter G; Morell B
Horm Metab Res Suppl; 1979; (8):198-201. PubMed ID: 395079
[TBL] [Abstract][Full Text] [Related]
17. Insulin infusion pumps in the treatment of diabetes.
Blackshear PJ
Med Instrum; 1982; 16(1):17-9. PubMed ID: 7038411
[TBL] [Abstract][Full Text] [Related]
18. A portable, Preprogrammable insulin infusion system with 16 rates.
Kølendorf K; Bojsen J
Horm Metab Res Suppl; 1979; (8):65-6. PubMed ID: 395092
[TBL] [Abstract][Full Text] [Related]
19. Preprogrammed insulin infusion with a portable pump system.
Irsigler K; Kritz H; Kaspar L; Brändle J; Koller W; Franetzki M
Horm Metab Res Suppl; 1979; (8):193-7. PubMed ID: 119699
[TBL] [Abstract][Full Text] [Related]
20. [Treatment of ambulatory unstable diabetic patients by continuous subcutaneous infusion of insulin: preliminary results (author's transl)].
Lambert AE; Buysschaert M; Van Halle B
Diabete Metab; 1979 Dec; 5(4):307-12. PubMed ID: 398299
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]