These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

58 related articles for article (PubMed ID: 3984460)

  • 1. [New instruments for the removal of an artificial hip joint from the shaft].
    Brinckmann P; Horst M
    Z Orthop Ihre Grenzgeb; 1985; 123(1):113-4. PubMed ID: 3984460
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Removal of broken stems of total joint components by a new method: drilling, undercutting, and extracting without damage to bone.
    Harris WH; White RE; Mitchell S; Barber F
    Hip; 1981; ():37-45. PubMed ID: 7333893
    [No Abstract]   [Full Text] [Related]  

  • 3. Modular femoral stem removal during total hip arthroplasty using a universal modular stem extractor.
    Bohn WW
    Clin Orthop Relat Res; 1992 Dec; (285):155-7. PubMed ID: 1446432
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Removal of bone cement from the femoral shaft using a femoral windowing device.
    Nelson CL; Barnes CL
    J Arthroplasty; 1990 Mar; 5(1):67-9. PubMed ID: 2319251
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The window technique for the removal of broken femoral stems in total hip replacement.
    Moreland JR; Marder R; Anspach WE
    Clin Orthop Relat Res; 1986 Nov; (212):245-9. PubMed ID: 3769290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasonic technology in revision joint arthroplasty.
    Klapper RC; Caillouette JT; Callaghan JJ; Hozack WJ
    Clin Orthop Relat Res; 1992 Dec; (285):147-54. PubMed ID: 1446431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Femoral cement removal in revision total hip arthroplasty. A biomechanical analysis.
    Dennis DA; Dingman CA; Meglan DA; O'Leary JF; Mallory TH; Berme N
    Clin Orthop Relat Res; 1987 Jul; (220):142-7. PubMed ID: 3594984
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hip rotationplasty with antibiotic-loaded bone cement spacer for severe infection following limb-sparing surgery.
    Okazaki N; Kumagai K; Egashira M; Osaki M; Murata M; Tomita M; Shindo H
    Orthopedics; 2008 Jul; 31(7):713. PubMed ID: 19292368
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The femoral stent. Surgical technique for a new method of cementing the femoral component in the presence of a large cortical defect.
    Freiberg AA; Harris WH
    Am J Orthop (Belle Mead NJ); 1995 Jun; 24(6):501-3. PubMed ID: 7670875
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Techniques of extraction of well-fixed cemented and cementless implants in revision total hip arthroplasty.
    Pierson JL; Jasty M; Harris WH
    Orthop Rev; 1993 Aug; 22(8):904-16. PubMed ID: 8265229
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Histological findings of the femoral bone after cement removal in hip revision. An experimental study of cadaver femurs with two different cement removal procedures.
    Porsch M; Schmidt J
    Arch Orthop Trauma Surg; 2003 Jun; 123(5):199-202. PubMed ID: 12743715
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new technique for removal of broken femoral stems in total hip replacement. A technical note.
    Harris WH; White RE; Mitchel S; Barber F
    J Bone Joint Surg Am; 1981 Jun; 63(5):843-5. PubMed ID: 7240311
    [No Abstract]   [Full Text] [Related]  

  • 14. Modified transfemoral approach to revision arthroplasty with uncemented modular revision stems.
    Fink B; Grossmann A
    Oper Orthop Traumatol; 2007 Mar; 19(1):32-55. PubMed ID: 17345026
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Personal experience with the Wagner revision stem in hip joint reoperations].
    Cech O; StehlĂ­k J; Krbec M; Vrecion V
    Acta Chir Orthop Traumatol Cech; 2001; 68(3):148-61. PubMed ID: 11706537
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Revisions with cemented long-stem prostheses.
    Turner RH; Scheller AD; Emerson RH
    Hip; 1984; ():322-41. PubMed ID: 6396278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Removal of cementless stems.
    Berry DJ
    Instr Course Lect; 2003; 52():331-6. PubMed ID: 12690861
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A new instrument for the removal of broken distal hip prosthesis shaft fragments].
    Ehall R; Stampfel O; Neubauer W; Engelke K
    Aktuelle Traumatol; 1990 Feb; 20(1):50-2. PubMed ID: 1969697
    [No Abstract]   [Full Text] [Related]  

  • 19. Cement removal in revision total hip arthroplasty.
    Lombardi AV
    Semin Arthroplasty; 1992 Oct; 3(4):264-72. PubMed ID: 10147936
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral windows in revision total hip arthroplasty.
    Klein AH; Rubash HE
    Clin Orthop Relat Res; 1993 Jun; (291):164-70. PubMed ID: 8504595
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.