These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 3986138)

  • 1. Detection of abnormal haemoglobins by the Technicon H6000 automated cell counter.
    Rees J; Williamson D; Carrell RW
    Br J Haematol; 1985 Apr; 59(4):734-6. PubMed ID: 3986138
    [No Abstract]   [Full Text] [Related]  

  • 2. Differential white cell counting on the Coulter Counter Model S Plus IV (three population) and the Technicon H6000; a comparison by simple and multiple regression.
    Clarke PT; Henthorn JS; England JM
    Clin Lab Haematol; 1985; 7(4):335-51. PubMed ID: 3830531
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of total white blood cell counts on the Technicon H6000 and Coulter Counter Model ZBI in an occupational health program.
    Garland FC; Seal GM; White MR
    Am J Clin Pathol; 1984 Mar; 81(3):349-52. PubMed ID: 6702727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of performance for leukocyte differential counting of the Technicon H6000 system with a manual reference method using the NCCLS standard.
    Breakell ES; Marchand A; Marcus R; Simson E
    Blood Cells; 1985; 11(2):257-79. PubMed ID: 3834964
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of the differential white blood cell count using the Technicon H1, the Technicon H6000 and the Coulter VCS.
    Stølsnes B; Skare EV; Taverner P; Ommundsen T; Aga IB; Sandberg S
    Eur J Haematol Suppl; 1990; 53():38-40. PubMed ID: 2279553
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of haemoglobin on the Technicon H6000 eosinophil count.
    Reardon DM; Hewitt J
    Clin Lab Haematol; 1986; 8(4):369-70. PubMed ID: 3791889
    [No Abstract]   [Full Text] [Related]  

  • 7. Detection of abnormal haemoglobins by the Sysmex NE-8000 automated cell counter.
    Lamb AA; Matteliano S; Freedman JJ
    Br J Haematol; 1991 Apr; 77(4):567-8. PubMed ID: 2025584
    [No Abstract]   [Full Text] [Related]  

  • 8. Detection of abnormal haemoglobins by the Sysmex NE-8000 automated cell counter.
    Br J Haematol; 1991 Dec; 79(4):656-7. PubMed ID: 1772792
    [No Abstract]   [Full Text] [Related]  

  • 9. Diagnosis of leukocyte disorders with an automated haematology counter (Technicon H-1 analyser).
    Teo CP; Fraser A; Han P
    Ann Acad Med Singap; 1989 Jul; 18(4):363-9. PubMed ID: 2802504
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Resistance to lysis of erythrocytes containing haemoglobin C--detected in a differential white cell counting system.
    Booth F; Mead SV
    J Clin Pathol; 1983 Jul; 36(7):816-8. PubMed ID: 6863574
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A rare case of Hemoglobin Leiden interfering with the DIFF channel of Sysmex XE-2100.
    Rosetti M; Poletti G; Sensi A; Ravani A; Rondoni M; Baldrati L; Dorizzi RM
    Scand J Clin Lab Invest; 2015 Sep; 75(5):436-7. PubMed ID: 25874481
    [No Abstract]   [Full Text] [Related]  

  • 12. Detection and quantitation of normal and variant haemoglobins: an analytical review.
    Wild BJ; Bain BJ
    Ann Clin Biochem; 2004 Sep; 41(Pt 5):355-69. PubMed ID: 15333187
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The unstable haemoglobins.
    Huehns ER
    Bull Soc Chim Biol (Paris); 1970; 52(11):1131-46. PubMed ID: 4927418
    [No Abstract]   [Full Text] [Related]  

  • 14. [Further evolution and leukocyte differential using an automated blood cell counter].
    Takubo T; Tatsumi N
    Rinsho Byori; 1995 Sep; 43(9):925-30. PubMed ID: 7474456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].
    Cart-Lamy P; Pernod G; Pirraud M; Drevait JM; Caillat D; Polack B; Kolodié L
    Ann Biol Clin (Paris); 1993; 51(6):627-35. PubMed ID: 8172402
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Abnormal haemoglobins and thalassaemia: methods and control.
    Stephens AD
    Acta Haematol; 1985; 74(1):1-5. PubMed ID: 3934899
    [No Abstract]   [Full Text] [Related]  

  • 17. The abnormal haemoglobins in homozygous alpha-thalassaemia.
    Todd D; Lai MC; Beaven GH; Huehns ER
    Br J Haematol; 1970 Jul; 19(1):27-31. PubMed ID: 5465779
    [No Abstract]   [Full Text] [Related]  

  • 18. Inefficacy of moving average algorithm as principal quality control procedure on Technicon System H6000.
    Tramacere P; Marocchi A; Gerthoux P; Beretta C; Brivio R; Mocarelli P
    Am J Clin Pathol; 1991 Feb; 95(2):218-21. PubMed ID: 1992611
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of the Technicon H-6000 automated system for executing hemograms and differential leukocyte counts].
    Jou JM; Vives Corrons JL; Insa MJ; Fernández G; Colomer E; del Olmo J; Seuma J; Ester A; Pérez Vila E
    Sangre (Barc); 1984; 29(1):73-86. PubMed ID: 6719321
    [No Abstract]   [Full Text] [Related]  

  • 20. An automated screening technique for the detection of sickle-cell haemoglobin.
    Canning DM; Crane RS; Huntsman RG; Yawson GI
    J Clin Pathol; 1972 Apr; 25(4):330-4. PubMed ID: 5028640
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.