146 related articles for article (PubMed ID: 4000009)
1. The bubble oxygenator as a source of gaseous microemboli.
Yost G
Med Instrum; 1985; 19(2):67-9. PubMed ID: 4000009
[TBL] [Abstract][Full Text] [Related]
2. A clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators.
Pearson DT; Holden MP; Poslad SJ; Murray A; Waterhouse PS
Life Support Syst; 1984; 2(4):252-66. PubMed ID: 6441873
[TBL] [Abstract][Full Text] [Related]
3. Product design and its relation to the generation of gaseous microemboli in the extracorporeal circuit.
Servas FM
Med Instrum; 1985; 19(2):63-6. PubMed ID: 4000008
[TBL] [Abstract][Full Text] [Related]
4. Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison.
Schuldes M; Riley JB; Francis SG; Clingan S
J Extra Corpor Technol; 2016 Sep; 48(3):129-136. PubMed ID: 27729706
[TBL] [Abstract][Full Text] [Related]
5. Biophysical aspects of gas bubbles in blood.
Butler BD
Med Instrum; 1985; 19(2):59-62. PubMed ID: 3889566
[TBL] [Abstract][Full Text] [Related]
6. Gaseous microemboli production of bubble and membrane oxygenators.
Pearson DT; Holden MP; Poslad SJ
Life Support Syst; 1986; 4 Suppl 1():198-208. PubMed ID: 3747601
[No Abstract] [Full Text] [Related]
7. Gaseous microemboli: sources, causes, and clinical considerations.
Kurusz M
Med Instrum; 1985; 19(2):73-6. PubMed ID: 4000011
[TBL] [Abstract][Full Text] [Related]
8. The detection of microemboli in the middle cerebral artery during cardiopulmonary bypass: a transcranial Doppler ultrasound investigation using membrane and bubble oxygenators.
Padayachee TS; Parsons S; Theobold R; Linley J; Gosling RG; Deverall PB
Ann Thorac Surg; 1987 Sep; 44(3):298-302. PubMed ID: 2957966
[TBL] [Abstract][Full Text] [Related]
9. Comparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.
Sutton RG; Riley JB; Merrill JH
J Extra Corpor Technol; 1994; 26(2):56-60. PubMed ID: 10147369
[TBL] [Abstract][Full Text] [Related]
10. In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.
Wang S; Caneo LF; Jatene MB; Jatene FB; Cestari IA; Kunselman AR; Ündar A
Artif Organs; 2017 Sep; 41(9):865-874. PubMed ID: 28597590
[TBL] [Abstract][Full Text] [Related]
11. Gaseous microemboli and the influence of microporous membrane oxygenators.
Weitkemper HH; Oppermann B; Spilker A; Knobl HJ; Körfer R
J Extra Corpor Technol; 2005 Sep; 37(3):256-64. PubMed ID: 16350377
[TBL] [Abstract][Full Text] [Related]
12. Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.
Glass K; Trivedi P; Wang S; Woitas K; Kunselman AR; Ündar A
Artif Organs; 2017 Apr; 41(4):392-400. PubMed ID: 28397410
[TBL] [Abstract][Full Text] [Related]
13. Clinical evaluation of the air-handling properties of contemporary oxygenators with integrated arterial filter.
Stehouwer MC; Legg KR; de Vroege R; Kelder JC; Hofman E; de Mol BA; Bruins P
Perfusion; 2017 Mar; 32(2):118-125. PubMed ID: 27516417
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.
Guan Y; Palanzo D; Kunselman A; Undar A
Artif Organs; 2009 Nov; 33(11):1037-43. PubMed ID: 19874280
[TBL] [Abstract][Full Text] [Related]
15. In vitro elimination of gaseous microemboli utilizing hypobaric oxygenation in the Terumo® FX15 oxygenator.
Clingan S; Schuldes M; Francis S; Hoerr H; Riley J
Perfusion; 2016 Oct; 31(7):552-9. PubMed ID: 26993481
[TBL] [Abstract][Full Text] [Related]
16. Clinical evaluation of the air removal characteristics of an oxygenator with integrated arterial filter in a minimized extracorporeal circuit.
Stehouwer MC; Boers C; de Vroege R; C Kelder J; Yilmaz A; Bruins P
Int J Artif Organs; 2011 Apr; 34(4):374-82. PubMed ID: 21534248
[TBL] [Abstract][Full Text] [Related]
17. Impact of oxygenator characteristics on its capability to remove gaseous microemboli.
De Somer F
J Extra Corpor Technol; 2007 Dec; 39(4):271-3. PubMed ID: 18293817
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter.
Salavitabar A; Qiu F; Kunselman A; Ündar A
Perfusion; 2010 Nov; 25(6):409-15. PubMed ID: 20699287
[TBL] [Abstract][Full Text] [Related]
19. Retrospective Analysis of Air Handling by Contemporary Oxygenators in the Setting of Cardiac Surgery.
Benstoem C; Bleilevens C; Borchard R; Stoppe C; Goetzenich A; Autschbach R; Breuer T
Ann Thorac Cardiovasc Surg; 2018 Oct; 24(5):230-237. PubMed ID: 29998925
[TBL] [Abstract][Full Text] [Related]
20. An in vitro evaluation of gaseous microemboli handling by contemporary venous reservoirs and oxygenator systems using EDAC.
Stanzel RD; Henderson M
Perfusion; 2016 Jan; 31(1):38-44. PubMed ID: 25987549
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]