  • 1. Obstruction of an endotracheal tube by the plastic coating sheared from a stylet.
    Cook WP; Schultetus RR
    Anesthesiology; 1985 Jun; 62(6):803-4. PubMed ID: 4003804
    [No Abstract]   [Full Text] [Related]  

  • 2. Fluoroscopy-guided retrieval of a sheared endotracheal stylet sheath from the tracheobronchial tree in a premature infant.
    Boyd RL; Bradfield HA; Burton EM; Carter BS
    Pediatr Radiol; 1999 Aug; 29(8):575-7. PubMed ID: 10415179
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The obstruction of an endotracheal tube by the plastic coating sheared from a stylet: a revisit.
    Bhargava M; Pothula SN; Joshi S
    Anesthesiology; 1998 Feb; 88(2):548-9. PubMed ID: 9477085
    [No Abstract]   [Full Text] [Related]  

  • 4. Pulmonary migration of a fragment of plastic coating sheared from a stylet.
    Chalhoub V; Richa F; El-Rassi I; Dagher C; Yazbeck P
    J Emerg Med; 2013 Jun; 44(6):1097-100. PubMed ID: 23332801
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acute airway obstruction by a sheared endotracheal intubation stylet sheath in a premature infant.
    Chiou HL; Diaz R; Orlino E; Poulain FR
    J Perinatol; 2007 Nov; 27(11):727-9. PubMed ID: 17960145
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endobronchial obstruction from an intubation stylet sheath.
    Koodiyedath B; Tyler W; Deshpande SA; Parikh D
    Neonatology; 2008; 94(4):304-5. PubMed ID: 18784428
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Laryngeal morbidity after tracheal intubation: the Endoflex(®) tube compared to conventional endotracheal intubation with stylet.
    Sørensen MK; Rasmussen N; Kristensen MS; Bøttger M; Fredensborg BB; Hansen CM; Rasmussen LS
    Acta Anaesthesiol Scand; 2013 Jul; 57(6):737-44. PubMed ID: 23379725
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia. Case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 24565248
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Shearing of plastic coating of stylet with double lumen tube: another incident.
    Sinha PK; Dubey PK
    Anesthesiology; 1999 Jan; 90(1):326-7. PubMed ID: 9915350
    [No Abstract]   [Full Text] [Related]  

  • 10. The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction.
    Rao GS; Ali Z; Ramkiran S; Chandrasekhar HS
    Anesth Analg; 2006 Dec; 103(6):1624-5. PubMed ID: 17122294
    [No Abstract]   [Full Text] [Related]  

  • 11. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia: case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 23931255
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Intratracheal foreign body caused by a sheared endotracheal intubation stylet].
    Schaffranietz L; Graz F; Tamke A
    Anaesthesist; 2009 Dec; 58(12):1223-5. PubMed ID: 20012244
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Intraoperative acute airway obstruction due to the damage of a reinforced endotracheal tube in thyroidectomy].
    Ida M; Kuzumoto N; Nakayama K; Krimoto K; Kamiya T; Iwata M; Shimomura T
    Masui; 2014 Oct; 63(10):1128-30. PubMed ID: 25693343
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Partial Obstruction of the Endotracheal Tube by the Plastic Coating Sheared from a Stylet.
    Das A; Chagalamarri S; Saridakis K
    Case Rep Pediatr; 2016; 2016():4373207. PubMed ID: 26989545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Obstruction of the left upper lobar bronchus by a double-lumen endotracheal tube. Apropos of a case].
    Pueyo JA; Fuentes R; Bustos A; Guerrero MI; Torres LM
    Rev Esp Anestesiol Reanim; 1992; 39(2):134. PubMed ID: 1594783
    [No Abstract]   [Full Text] [Related]  

  • 17. Obstruction of endotracheal tube; a manufacturing error.
    Hajimohammadi F; Taheri A; Eghtesadi-Araghi P
    Middle East J Anaesthesiol; 2009 Jun; 20(2):303-5. PubMed ID: 19583085
    [No Abstract]   [Full Text] [Related]  

  • 18. A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
    Sharma A; Jain V; Mitra JK; Prabhakar H
    Middle East J Anaesthesiol; 2008 Feb; 19(4):909-11. PubMed ID: 18630777
    [No Abstract]   [Full Text] [Related]  

  • 19. Silicone-based endotracheal tube causing airway obstruction and pneumothorax.
    Capra GG; Shah AN; Moore JD; Halsey WS; Lujan E
    Arch Otolaryngol Head Neck Surg; 2012 Jun; 138(6):588-91. PubMed ID: 22710512
    [No Abstract]   [Full Text] [Related]  

  • 20. Impacted gum-elastic bougie in an endotracheal tube after successful intubation of a difficult airway.
    Arya VK; Makker S; Bedi SP
    J Clin Anesth; 2007 Nov; 19(7):566. PubMed ID: 18063220
    [No Abstract]   [Full Text] [Related]  