These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 4010240)

  • 1. Monitoring of aluminum in whole blood, plasma, serum, and water by a single procedure using flameless atomic absorption spectrophotometry.
    van der Voet GB; de Haas EJ; de Wolff FA
    J Anal Toxicol; 1985; 9(3):97-100. PubMed ID: 4010240
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry.
    Parkinson IS; Ward MK; Kerr DN
    Clin Chim Acta; 1982 Oct; 125(2):125-33. PubMed ID: 7139954
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aluminum determination in whole blood, dialysis solution, and tap water samples from Maracaibo dialysis units (Venezuela) by graphite furnace atomic absorption spectrometry.
    Navarro JA; Parra OE; Romero RA
    J Trace Elem Electrolytes Health Dis; 1988 Mar; 2(1):3-8. PubMed ID: 2980789
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination by flameless atomic absorption of aluminium in serum and hair for toxicological monitoring of patients on chronic intermittent haemodialysis.
    De Groot HJ; De Haas EJ; D'Haese P; Heyndrickx A; De Wolff FA
    Pharm Weekbl Sci; 1984 Feb; 6(1):11-5. PubMed ID: 6709481
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Serum and dialysate aluminium concentration of dialysed patients with chronic renal failure determined by atomic absorption spectrometry with a graphite furnace.
    Mazzeo-Farina A; Cerulli N
    Clin Chim Acta; 1985 Apr; 147(3):247-54. PubMed ID: 3995774
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.
    Frech W; Cedergren A; Cederberg C; Vessman J
    Clin Chem; 1982 Nov; 28(11):2259-63. PubMed ID: 7127770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of aluminum in serum, blood, urine, and tissues of chronic hemodialyzed patients by use of electrothermal atomic absorption spectrometry.
    D'Haese PC; Van de Vyver FL; de Wolff FA; De Broe ME
    Clin Chem; 1985 Jan; 31(1):24-9. PubMed ID: 3965215
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of aluminium in serum, dialysate fluid and water by inductively coupled plasma optical emission spectrometry.
    Lyon TD; Cunningham C; Halls DJ; Gibbons J; Keating A; Fell GS
    Ann Clin Biochem; 1995 Mar; 32 ( Pt 2)():160-6. PubMed ID: 7785943
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Determination of aluminum traces in dialysis concentrates].
    Bohrer Do Nascimento D; Schwedt G
    Pharmazie; 1993 Sep; 48(9):676-8. PubMed ID: 8234400
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Distribution of aluminium between plasma and erythrocytes.
    van der Voet GB; de Wolff FA
    Hum Toxicol; 1985 Nov; 4(6):643-8. PubMed ID: 4077077
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Toxicological aspects of aluminum poisoning in clinical nephrology.
    de Wolff FA
    Clin Nephrol; 1985; 24 Suppl 1():S9-14. PubMed ID: 3842105
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aluminum levels in normal human serum and urine as determined by Zeeman atomic absorption spectrometry.
    Wang ST; Pizzolato S; Demshar HP
    J Anal Toxicol; 1991; 15(2):66-70. PubMed ID: 2051747
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrafiltration studies in vitro of serum aluminum in dialysis patients after deferoxamine chelation therapy.
    Leung FY; Hodsman AB; Muirhead N; Henderson AR
    Clin Chem; 1985 Jan; 31(1):20-3. PubMed ID: 3965214
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid and reliable method for the determination of aluminium in bone by electrothermal atomic absorption spectrometry.
    Tang S; Parsons PJ; Slavin W
    Analyst; 1996 Feb; 121(2):195-200. PubMed ID: 8849038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of aluminum in blood, urine, and water by inductively coupled plasma emission spectrometry.
    Allain P; Mauras Y
    Anal Chem; 1979 Nov; 51(13):2089-91. PubMed ID: 532969
    [No Abstract]   [Full Text] [Related]  

  • 16. Extraction spectrophotometric determination of aluminum in dialysis concentrates with 3,5-ditertbutylsalicylfluorone and ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate.
    Li Z; Lu N; Zhou X; Song Q
    J Pharm Biomed Anal; 2007 Apr; 43(5):1609-14. PubMed ID: 17184954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.
    Bertholf RL; Brown S; Renoe BW; Wills MR; Savory J
    Clin Chem; 1983 Jun; 29(6):1087-9. PubMed ID: 6851100
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrothermal atomic absorption spectrometric determination of aluminum in serum with a new technique for protein precipitation.
    Brown S; Bertholf RL; Wills MR; Savory J
    Clin Chem; 1984 Jul; 30(7):1216-8. PubMed ID: 6329554
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Plasma aluminum concentrations in long-term mechanically ventilated patients receiving stress ulcer prophylaxis with sucralfate.
    Tryba M; Kurz-Müller K; Donner B
    Crit Care Med; 1994 Nov; 22(11):1769-73. PubMed ID: 7956280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved determination of aluminum in serum and urine with use of a stabilized temperature platform furnace.
    Leung FY; Henderson AR
    Clin Chem; 1982 Oct; 28(10):2139-43. PubMed ID: 7127743
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.