These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

56 related articles for article (PubMed ID: 401259)

  • 1. Prothesis cement envelope in femoral component total hips.
    Savino AW; Andersson GB; Andriacchi TP; Galante JO
    Surg Forum; 1978; 29():556-7. PubMed ID: 401259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction.
    Crowninshield RD; Brand RA; Johnston RC; Milroy JC
    Clin Orthop Relat Res; 1980; (146):71-7. PubMed ID: 7371271
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental study in femoral component total hip replacement: mechanical failures of cement-bone interface with comparison of prosthesis, cement thickness, orientation and plug insertion.
    Savino AW
    Proc Inst Med Chic; 1978; 32(1):13-4. PubMed ID: 662836
    [No Abstract]   [Full Text] [Related]  

  • 5. The influence of femoral stem thickness and implantation technique on the strength of the bone cement bond.
    Savino AW; Andersson GB; Andriacchi TP; Hampton S; Galante JO
    Acta Orthop Scand; 1982 Feb; 53(1):23-7. PubMed ID: 7064678
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing.
    O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH
    J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [A simple technique of removal of femoral cement plug in total hip prosthesis revision].
    Julliard R
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(2):161-5. PubMed ID: 8761102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months].
    Migaud H; Jardin C; Fontaine C; Pierchon F; d'Herbomez O; Duquennoy A
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(4):360-7. PubMed ID: 9452810
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape.
    Bourne RB; Oh I; Harris WH
    Clin Orthop Relat Res; 1984 Mar; (183):12-6. PubMed ID: 6697578
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stable partial debonding of the cement interfaces indicated by a finite element model of a total hip prosthesis.
    Lu Z; Ebramzadeh E; McKellop H; Sarmiento A
    J Orthop Res; 1996 Mar; 14(2):238-44. PubMed ID: 8648501
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of stem geometry on mechanics of cemented femoral hip components with a proximal bond.
    Mann KA; Bartel DL; Ayers DC
    J Orthop Res; 1997 Sep; 15(5):700-6. PubMed ID: 9420599
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty.
    Cheal EJ; Spector M; Hayes WC
    J Orthop Res; 1992 May; 10(3):405-22. PubMed ID: 1569504
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reinforcement of bone cement around the femoral prosthesis tip by pre-coated wire coil: a human cadaver bone study.
    Kim JK; Park JB
    Biomed Mater Eng; 1996; 6(3):159-64. PubMed ID: 8922261
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of an expandable stem total hip replacement system.
    Kummer FJ; Strauss EJ; Jaffe WL
    Bull NYU Hosp Jt Dis; 2007; 65(2):101-5. PubMed ID: 17581101
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Early aseptic loosening of the CF 30 femoral stem].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [An original procedure for cement diaphyseal extraction. The segmental cement extraction system or SEG-CES].
    Cordonnier D; Desrousseaux JF; Polveche G; Rattier B; d'Almeida M; Vinchon B
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(2):166-70. PubMed ID: 8761103
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cement strain measurement surrounding loose and well-fixed femoral component stems.
    Crowninshield RD; Tolbert JR
    J Biomed Mater Res; 1983 Sep; 17(5):819-28. PubMed ID: 6619178
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of stem length on mechanics of the femoral hip component after cemented revision.
    Mann KA; Ayers DC; Damron TA
    J Orthop Res; 1997 Jan; 15(1):62-8. PubMed ID: 9066528
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.