BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 4015006)

  • 1. [Thromboembolic accidents in patients with mechanical prostheses and heterografts].
    Ben Ismail M; Abid F; Boughzela E; Ayari M
    Ann Cardiol Angeiol (Paris); 1985 Apr; 34(4):197-203. PubMed ID: 4015006
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Embolic complications of porcine heterograft cardiac valves.
    Jamieson WR; Janusz MT; Miyagishima RT; Munro AI; Tutassura H; Gerein AN; Burr LH; Allen P
    J Thorac Cardiovasc Surg; 1981 Apr; 81(4):626-31. PubMed ID: 7206772
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).
    Orszulak TA; Schaff HV; DeSmet JM; Danielson GK; Pluth JR; Puga FJ
    J Thorac Cardiovasc Surg; 1993 Feb; 105(2):302-12. PubMed ID: 8429659
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Thromboembolic and hemorrhagic complications in valve prosthesis patients].
    Ben Ismail M; Abid F; Abid A; M'Zah N; Chaouche H; Kedidi N
    Ann Cardiol Angeiol (Paris); 1983 Jun; 32(4):237-45. PubMed ID: 6614815
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Replacement of the mitral and aortic valves with bioprostheses. Long-term results].
    Colombo T; Cicardi C; Peronace B; Pozzi M; Gordini V; Pellegrini A
    G Ital Cardiol; 1985 Oct; 15(10):974-82. PubMed ID: 4092917
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Long-term antithrombotic treatment in patients with valve prostheses. Practical management and complications].
    Delahaye JP; Milon H; Ffrench P; Philippe-Bert J; Malquarti V; Saradarian W
    Ann Cardiol Angeiol (Paris); 1985 Apr; 34(4):205-11. PubMed ID: 3893303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Thromboembolism with the Ionescu-Shiley bovine pericardial bioprosthesis. Long-term results (11 years)].
    González-Juanatey JR; Rubio Alvarez J; Sierra Quiroga J; Durán Muñoz D; Gil de la Peña M; García-Bengoechea JB
    Rev Esp Cardiol; 1990 Jan; 43(1):6-12. PubMed ID: 2315544
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Unexpected findings concerning thromboembolic complications and anticoagulation after complete 10 year follow up of patients with St. Jude Medical prostheses.
    Horstkotte D; Schulte H; Bircks W; Strauer B
    J Heart Valve Dis; 1993 May; 2(3):291-301. PubMed ID: 8269122
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparative evaluation of various methods of treatment of mitral valve diseases. Apropos of 4 series of 100 patients operated on using the Starr prosthesis, Bjork prosthesis, bioprosthesis and valve reconstruction].
    Perier P; Deloche A; Rossand P; Fabiani JN; Bessou JP; Bourezak H; Chachques JC; d'Allaines C; Blondeau P; Carpentier A
    Arch Mal Coeur Vaiss; 1984 Dec; 77(13):1517-24. PubMed ID: 6440502
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience.
    Goldsmith I; Lip GY; Mukundan S; Rosin MD
    J Heart Valve Dis; 1998 Sep; 7(5):574-9. PubMed ID: 9793859
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The Carpentier-Edwards porcine valve in the supra annular aortic position. Results after 12 years in a series of 1108 patients].
    Logeais Y; Leguerrier A; Rioux C; Chaperon J; Lelong B; Langanay T; Delambre JF; el Issa A; Valla J
    Arch Mal Coeur Vaiss; 1997 Jun; 90(6):779-88. PubMed ID: 9295930
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical comparison of St. Jude and porcine aortic valve prostheses.
    Douglas PS; Hirshfeld JW; Edie RN; Harken AH; Stephenson LW; Edmunds LH
    Circulation; 1985 Sep; 72(3 Pt 2):II135-9. PubMed ID: 4028357
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The homograft aortic valve: a 29-year, 99.3% follow up of 1,022 valve replacements.
    O'Brien MF; Harrocks S; Stafford EG; Gardner MA; Pohlner PG; Tesar PJ; Stephens F
    J Heart Valve Dis; 2001 May; 10(3):334-44; discussion 335. PubMed ID: 11380096
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prosthetic valves or tissue valves--a vote for mechanical prostheses.
    Horstkotte D
    Z Kardiol; 1985; 74 Suppl 6():19-37. PubMed ID: 4096074
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early and late risk of aortic valve replacement. A 12 year concomitant comparison of the porcine bioprosthetic and tilting disc prosthetic aortic valves.
    Cohn LH; Allred EN; DiSesa VJ; Sawtelle K; Shemin RJ; Collins JJ
    J Thorac Cardiovasc Surg; 1984 Nov; 88(5 Pt 1):695-705. PubMed ID: 6492838
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Thromboembolic complications in patients with prostheses].
    Acar J
    Ann Cardiol Angeiol (Paris); 1985 Dec; 34(10):697-701. PubMed ID: 4091502
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Late results after Starr-Edwards valve replacement in children.
    Schaff HV; Danielson GK; DiDonato RM; Puga FJ; Mair DD; McGoon DC
    J Thorac Cardiovasc Surg; 1984 Oct; 88(4):583-9. PubMed ID: 6482490
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
    Horstkotte D; Körfer R; Budde T; Haerten K; Schulte HD; Bircks W; Loogen F
    Z Kardiol; 1983 May; 72(5):251-61. PubMed ID: 6880335
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Intermediary results with the CarboMedics bileaflet valvular prosthesis].
    Aupart M; Diemont F; Babuty D; Fauchier L; Sirinelli A; Marchand M
    Arch Mal Coeur Vaiss; 1997 Apr; 90(4):457-62. PubMed ID: 9238462
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The frequency of risk factors of thromboembolic and hemorrhagic complications in patients treated with oral anticoagulants after heart valve replacement].
    Wołkanin-Bartnik J; Zieliński T; Pogorzelska H; Browarek A; Leszek P; Korewicki J
    Pol Merkur Lekarski; 2005 May; 18(107):503-10. PubMed ID: 16161943
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.