These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 4023661)

  • 41. Mechanics of the patellar articulation. Effects of patellar ligament length studied with a mathematical model.
    van Eijden TM; Kouwenhoven E; Weijs WA
    Acta Orthop Scand; 1987 Oct; 58(5):560-6. PubMed ID: 3425289
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The variation in the orientations and moment arms of the knee extensor and flexor muscle tendons with increasing muscle force: a mathematical analysis.
    Imran A; Huss RA; Holstein H; O'Connor JJ
    Proc Inst Mech Eng H; 2000; 214(3):277-86. PubMed ID: 10902442
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Quantification of intact quadriceps tendon, quadriceps tendon insertion, and suprapatellar fat pad: MR arthrography, anatomy, and cryosections in the sagittal plane.
    Staeubli HU; Bollmann C; Kreutz R; Becker W; Rauschning W
    AJR Am J Roentgenol; 1999 Sep; 173(3):691-8. PubMed ID: 10470905
    [TBL] [Abstract][Full Text] [Related]  

  • 44. In-vitro measurement of static pressure distribution in synovial joints--Part II: Retropatellar surface.
    Ahmed AM; Burke DL; Yu A
    J Biomech Eng; 1983 Aug; 105(3):226-36. PubMed ID: 6632824
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Patellar tendon in vivo regional strain with varying knee angle.
    Pearson SJ; Mohammed ASA; Hussain SR
    J Biomech; 2017 Aug; 61():45-50. PubMed ID: 28736078
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Role of peripatellar retinaculum in transmission of forces within the extensor mechanism.
    Powers CM; Chen YJ; Farrokhi S; Lee TQ
    J Bone Joint Surg Am; 2006 Sep; 88(9):2042-8. PubMed ID: 16951122
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Tibiofemoral joint forces during isokinetic knee extension.
    Nisell R; Ericson MO; NĂ©meth G; Ekholm J
    Am J Sports Med; 1989; 17(1):49-54. PubMed ID: 2929836
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Biomechanical evaluation of an adjustable patellar tendon bearing prosthesis.
    Mizrahi J; Susak Z; Bahar A; Seliktar R; Najenson T
    Scand J Rehabil Med Suppl; 1985; 12():117-23. PubMed ID: 3868036
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Influences of configuration changes of the patella on the knee extensor mechanism.
    C-K C; N-K Y; H-C L; K-S L
    Clin Biomech (Bristol); 1996 Mar; 11(2):116-120. PubMed ID: 11415607
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Patellofemoral contact pressures.
    Quintelier J; Skalski K; Verdonk P; De Baets P; Almqvist F
    Acta Bioeng Biomech; 2008; 10(2):23-8. PubMed ID: 19031994
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The influence of changes in patellar and femoral prosthesis on knee extensor mechanism after TKA.
    He Y; Wang C
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2005():6180-3. PubMed ID: 17281676
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Biomechanical studies of the rabbit patellar tendon after removal of its one-fourth or a half.
    Yamamoto N; Hayashi K; Hayashi F; Yasuda K; Kaneda K
    J Biomech Eng; 1999 Jun; 121(3):323-9. PubMed ID: 10396699
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Biomechanics of the patello-femoral joint].
    Maquet P
    Acta Orthop Belg; 1978; 44(1):41-54. PubMed ID: 665193
    [No Abstract]   [Full Text] [Related]  

  • 54. Regional variations in human patellar trabecular architecture and the structure of the proximal patellar tendon enthesis.
    Toumi H; Higashiyama I; Suzuki D; Kumai T; Bydder G; McGonagle D; Emery P; Fairclough J; Benjamin M
    J Anat; 2006 Jan; 208(1):47-57. PubMed ID: 16420378
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Mechanical properties of the rabbit patellar tendon.
    Yamamoto N; Hayashi K; Kuriyama H; Ohno K; Yasuda K; Kaneda K
    J Biomech Eng; 1992 Aug; 114(3):332-7. PubMed ID: 1522727
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Applied biomechanics of the patella.
    Grelsamer RP; Weinstein CH
    Clin Orthop Relat Res; 2001 Aug; (389):9-14. PubMed ID: 11501829
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effects of growth on the response of the rabbit patellar tendon to stress shielding: a biomechanical study.
    Fujie H; Yamamoto N; Murakami T; Hayashi K
    Clin Biomech (Bristol); 2000 Jun; 15(5):370-8. PubMed ID: 10758299
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Analysis of the moment arms and kinematics of ostrich (Struthio camelus) double patellar sesamoids.
    Regnault S; Allen VR; Chadwick KP; Hutchinson JR
    J Exp Zool A Ecol Integr Physiol; 2017 Apr; 327(4):163-171. PubMed ID: 29356388
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Muscular and tibiofemoral joint forces during isokinetic concentric knee extension.
    Baltzopoulos V
    Clin Biomech (Bristol); 1995 Jun; 10(4):208-214. PubMed ID: 11415554
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Biomechanics of the patello-femoral joint. Part I: A study of the contact and the congruity of the patello-femoral compartment and movement of the patella.
    Fujikawa K; Seedhom BB; Wright V
    Eng Med; 1983 Jan; 12(1):3-11. PubMed ID: 6682059
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.