These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 4025749)

  • 1. If in doubt, take it out. Obstruction of tracheal tube by prominent aortic knuckle.
    Sapsford DJ; Snowdon SL
    Anaesthesia; 1985 Jun; 40(6):552-4. PubMed ID: 4025749
    [No Abstract]   [Full Text] [Related]  

  • 2. Tracheal tube obstruction by prominent aortic knuckle.
    Martin J; Hutchison B
    Anaesthesia; 1986 Jan; 41(1):86-7. PubMed ID: 3946784
    [No Abstract]   [Full Text] [Related]  

  • 3. [Tracheal tube obstruction mimicking a bronchospasm].
    Hugot P; Aguillon D; Musellec H; Breitel D; Gentili M
    Ann Fr Anesth Reanim; 2012 May; 31(5):488-90. PubMed ID: 22513179
    [No Abstract]   [Full Text] [Related]  

  • 4. Airway obstruction associated with an endotracheal tube.
    Støen R; Smith-Erichsen N
    Intensive Care Med; 1987; 13(4):295-6. PubMed ID: 3611502
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction.
    Rao GS; Ali Z; Ramkiran S; Chandrasekhar HS
    Anesth Analg; 2006 Dec; 103(6):1624-5. PubMed ID: 17122294
    [No Abstract]   [Full Text] [Related]  

  • 6. Silicone-based endotracheal tube causing airway obstruction and pneumothorax.
    Capra GG; Shah AN; Moore JD; Halsey WS; Lujan E
    Arch Otolaryngol Head Neck Surg; 2012 Jun; 138(6):588-91. PubMed ID: 22710512
    [No Abstract]   [Full Text] [Related]  

  • 7. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia. Case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 24565248
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia: case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 23931255
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraoperative airway obstruction due to dissection of a reinforced endotracheal tube in a prone patient.
    Rajkumar A; Bajekal R
    J Neurosurg Anesthesiol; 2011 Oct; 23(4):377. PubMed ID: 21876451
    [No Abstract]   [Full Text] [Related]  

  • 10. [Intraoperative acute airway obstruction due to the damage of a reinforced endotracheal tube in thyroidectomy].
    Ida M; Kuzumoto N; Nakayama K; Krimoto K; Kamiya T; Iwata M; Shimomura T
    Masui; 2014 Oct; 63(10):1128-30. PubMed ID: 25693343
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Medtronic electromyographic tracheal tube.
    Vera-Sanchez MB; Quintana-Villamandos B
    Anaesthesia; 2017 Oct; 72(10):1282-1283. PubMed ID: 28891058
    [No Abstract]   [Full Text] [Related]  

  • 12. A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
    Sharma A; Jain V; Mitra JK; Prabhakar H
    Middle East J Anaesthesiol; 2008 Feb; 19(4):909-11. PubMed ID: 18630777
    [No Abstract]   [Full Text] [Related]  

  • 13. Obstruction of endotracheal tube; a manufacturing error.
    Hajimohammadi F; Taheri A; Eghtesadi-Araghi P
    Middle East J Anaesthesiol; 2009 Jun; 20(2):303-5. PubMed ID: 19583085
    [No Abstract]   [Full Text] [Related]  

  • 14. [Obstruction of the left upper lobar bronchus by a double-lumen endotracheal tube. Apropos of a case].
    Pueyo JA; Fuentes R; Bustos A; Guerrero MI; Torres LM
    Rev Esp Anestesiol Reanim; 1992; 39(2):134. PubMed ID: 1594783
    [No Abstract]   [Full Text] [Related]  

  • 15. [Case report: lumen obstruction with a Magill tube].
    Deller A; Weichel T
    Anasth Intensivther Notfallmed; 1990 Aug; 25(4):293-4. PubMed ID: 2221303
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An unusual foreign body obstructing endotracheal tube connector.
    Roy B; Barman B; Dutta C; Basu SM
    J Indian Med Assoc; 1995 Sep; 93(9):358. PubMed ID: 8648160
    [No Abstract]   [Full Text] [Related]  

  • 17. Displaced nasal silicone implant: an unusual cause of nasotracheal tube obstruction.
    Lin HT; Day YJ; Sum DC; Liu FC; Liou JT
    J Clin Anesth; 2013 Jun; 25(4):344-5. PubMed ID: 23643541
    [No Abstract]   [Full Text] [Related]  

  • 18. [Massive pneumoperitoneum due to gastric perforation after difficult tracheal intubation].
    Muliterno E; Pardina B; Virolés G; Villalonga A
    Rev Esp Anestesiol Reanim; 2014; 61(7):411-2. PubMed ID: 24365643
    [No Abstract]   [Full Text] [Related]  

  • 19. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does your reinforced tube have a Murphy EYE?
    Im KS; Lee HJ; Lee JM
    Can J Anaesth; 2016 Sep; 63(9):1106-7. PubMed ID: 27233956
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.