These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
8. A laboratory investigation of two new portable gas analysers. Zbinden AM; Westenskow D; Thomson DA; Funk B; Maertens J Int J Clin Monit Comput; 1986; 2(3):151-61. PubMed ID: 3722981 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of three transportable multigas anesthetic monitors: the Bruel & Kjaer Anesthetic Gas Monitor 1304, the Datex Capnomac Ultima, and the Nellcor N-2500. Nielsen J; Kann T; Moller JT J Clin Monit; 1993 Apr; 9(2):91-8. PubMed ID: 8166778 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of infrared analysers used for monitoring waste anaesthetic gas levels in operating theatres. Ilsley AH; Crea J; Cousins MJ Anaesth Intensive Care; 1980 Nov; 8(4):436-40. PubMed ID: 7457813 [TBL] [Abstract][Full Text] [Related]
11. Cyclopropane and the Datex Capnomac. Effect of cyclopropane on the single wavelength infrared measurement of volatile anaesthetic agents. Mason DG; Lloyd-Thomas AR Anaesthesia; 1991 May; 46(5):398-9. PubMed ID: 2035792 [TBL] [Abstract][Full Text] [Related]
12. [NORMAC--a simple instrument to measure the inspiratory and end- expiratory concentrations of halothane, enflurane, and isoflurane. Clinical use and laboratory investigations]. Baer B Anaesthesist; 1987 May; 36(5):242-5. PubMed ID: 3631492 [TBL] [Abstract][Full Text] [Related]
13. [Evaluation of anesthetic vaporizers: application of the Normac infrared anesthetic agent monitor AA 102]. Nishioka K; Hoshi K; Takahashi S Masui; 1987 May; 36(5):778-83. PubMed ID: 3656647 [No Abstract] [Full Text] [Related]
14. Response time of the Narkotest anesthetic gas monitor. Velazquez JL; Feingold A; Walther P Anesth Analg; 1977; 56(3):395-7. PubMed ID: 559440 [TBL] [Abstract][Full Text] [Related]
15. Anaesthetic gas monitoring comparison between two side-stream monitors. Heijbel H; Ostblom J; Brattwall M; Jakobsson J J Clin Monit Comput; 2010 Apr; 24(2):169-72. PubMed ID: 20238153 [TBL] [Abstract][Full Text] [Related]
17. [A mistake in the filling of a vaporizer detected by an infrared analyser of halogenated anesthetic agents]. Baras E; Deriaz H; Lienhart A Ann Fr Anesth Reanim; 1989; 8(2):128-30. PubMed ID: 2735569 [TBL] [Abstract][Full Text] [Related]
18. An evaluation of the BrĂ¼el and Kjaer monitor 1304. McPeak HB; Palayiwa E; Robinson GC; Sykes MK Anaesthesia; 1992 Jan; 47(1):41-7. PubMed ID: 1536404 [TBL] [Abstract][Full Text] [Related]
19. Comparison of an infrared anaesthetic agent analyser (Datex-Ohmeda) with refractometry for measurement of isoflurane, sevoflurane and desflurane concentrations. Rudolff AS; Moens YP; Driessen B; Ambrisko TD Vet Anaesth Analg; 2014 Jul; 41(4):386-92. PubMed ID: 24330264 [TBL] [Abstract][Full Text] [Related]
20. Medical aerosol propellant interference with infrared anaesthetic gas monitors. Levin PD; Levin D; Avidan A Br J Anaesth; 2004 Jun; 92(6):865-9. PubMed ID: 15121726 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]