These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 4028758)

  • 1. Continuous polarographic monitoring of intra-arterial oxygen in the perioperative period.
    Bratanow N; Polk K; Bland R; Kram HB; Lee TS; Shoemaker WC
    Crit Care Med; 1985 Oct; 13(10):859-60. PubMed ID: 4028758
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy and utility of a continuous intra-arterial blood gas monitoring system in pediatric patients.
    Coule LW; Truemper EJ; Steinhart CM; Lutin WA
    Crit Care Med; 2001 Feb; 29(2):420-6. PubMed ID: 11246326
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous intra-arterial oxygen monitoring: accuracy and reliability in the surgical intensive care unit.
    Lemus JF; Kearney T; Margulies DR; Mackenzie DJ; Leyerle BJ; Shabot MM
    Am Surg; 1992 Dec; 58(12):740-2. PubMed ID: 1456597
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multisite evaluation of a continuous intraarterial blood gas monitoring system.
    Larson CP; Vender J; Seiver A
    Anesthesiology; 1994 Sep; 81(3):543-52. PubMed ID: 8092498
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical evaluation of a multiparameter intra-arterial blood-gas sensor.
    Abraham E; Gallagher TJ; Fink S
    Intensive Care Med; 1996 May; 22(5):507-13. PubMed ID: 8796412
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experiences with continuous intra-arterial blood gas monitoring.
    Menzel M; Henze D; Soukup J; Engelbrecht K; Senderreck M; Clausen T; Radke J
    Minerva Anestesiol; 2001 Apr; 67(4):325-31. PubMed ID: 11376534
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: a prospective, criterion standard study.
    Haller M; Kilger E; Briegel J; Forst H; Peter K
    Crit Care Med; 1994 Apr; 22(4):580-7. PubMed ID: 8143467
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous in-vivo blood-gas determination in man: reliability and safety of a new device.
    Richman KA; Jobes DR; Schwalb AJ
    Anesthesiology; 1980 Apr; 52(4):313-7. PubMed ID: 7362051
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time analysis of the change in arterial oxygen tension during endotracheal suction with a fiberoptic bronchoscope.
    Arai T; Hatano Y; Komatsu K; Takada T; Miyake C; Harioka T; Reshad K
    Crit Care Med; 1985 Oct; 13(10):855-8. PubMed ID: 4028757
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intra-arterial blood gas monitoring system: more accurate values can be obtained.
    Kurahashi K; Hirose Y; Yamada H; Toyoshima M; Usuda Y
    J Clin Monit; 1996 Mar; 12(2):141-7. PubMed ID: 8823634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nursing care of the Paratrend 7 sensor.
    Saich C; Graystone SJ; Hendry SP; Clutton-Brock TH
    Intensive Crit Care Nurs; 1997 Dec; 13(6):338-40. PubMed ID: 9564351
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial evaluation of a new intra-arterial blood gas system in humans.
    Zimmerman JL; Dellinger RP
    Crit Care Med; 1993 Apr; 21(4):495-500. PubMed ID: 8472566
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polarographic pO2 sensors with heparinized membranes for in vitro and continuous in vivo registration.
    Nilsson E; Edwall G; Larsson R; Olsson P
    Scand J Clin Lab Invest; 1981 Oct; 41(6):557-63. PubMed ID: 7336122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcutaneous Po2 monitoring in neonatal intensive care.
    Löfgren O; Henriksson P; Jacobson L; Johansson O
    Acta Paediatr Scand; 1978 Nov; 67(6):693-7. PubMed ID: 716868
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preliminary evaluation of a new continuous intra-arterial blood gas monitoring device.
    Pappert D; Rossaint R; Lewandowski K; Kuhlen R; Gerlach H; Falke KJ
    Acta Anaesthesiol Scand Suppl; 1995; 107():67-70. PubMed ID: 8599302
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous neonatal blood gas monitoring using a multiparameter intra-arterial sensor.
    Morgan C; Newell SJ; Ducker DA; Hodgkinson J; White DK; Morley CJ; Church JM
    Arch Dis Child Fetal Neonatal Ed; 1999 Mar; 80(2):F93-8. PubMed ID: 10325783
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous monitoring of mixed venous oxygen saturation in infants after cardiac surgery.
    Schranz D; Schmitt S; Oelert H; Schmid F; Huth R; Zimmer B; Schuind A; Vogel K; Stopfkuchen H; Jüngst BK
    Intensive Care Med; 1989; 15(4):228-32. PubMed ID: 2745866
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous blood gas monitoring using an in-dwelling optode method: comparison to intermittent arterial blood gas sampling in ECMO patients.
    Rais-Bahrami K; Rivera O; Mikesell GT; Short BL
    J Perinatol; 2002 Sep; 22(6):472-4. PubMed ID: 12168125
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of arterial blood gas with continuous intra-arterial and transcutaneous PO2 sensors in adult critically ill patients.
    Green GE; Hassell KT; Mahutte CK
    Crit Care Med; 1987 May; 15(5):491-4. PubMed ID: 3105958
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a new re-usable electrode for continuous monitoring of blood PO2 during open-heart surgery.
    Claremont DJ; Pagdin TM
    J Med Eng Technol; 1985; 9(4):174-9. PubMed ID: 4045985
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.