These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 4037663)

  • 1. Determination of aluminium in serum: findings of an external quality assessment scheme.
    Taylor A; Starkey BJ; Walker AW
    Ann Clin Biochem; 1985 Jul; 22 ( Pt 4)():351-8. PubMed ID: 4037663
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Determination of aluminum in serum using electrothermal atomic absorption spectrophotometry].
    Radosević P
    Arh Hig Rada Toksikol; 1991 Mar; 42(1):55-64. PubMed ID: 1854266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Interlaboratory tests: completion of a method of aluminum assay in serum by electrothermal atomic absorption spectrometry].
    Pineau A; Chappuis P; Arnaud J; Baruthio F; Zawislak R; Jaudon MC
    Ann Biol Clin (Paris); 1992; 50(8):577-85. PubMed ID: 1294013
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aluminium and silicon speciation in human serum by lon-exchange high-performance liquid chromatography-electrothermal atomic absorption spectrometry and gel electrophoresis.
    Wróbel K; González EB; Wróbel K; Sanz-Medel A
    Analyst; 1995 Mar; 120(3):809-15. PubMed ID: 7741232
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrothermal determination of aluminum in biological samples by atomic absorption spectroscopy.
    Gitelman HJ; Alderman FR
    Kidney Int Suppl; 1986 Feb; 18():S28-31. PubMed ID: 3457991
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of aluminium in serum, dialysate fluid and water by inductively coupled plasma optical emission spectrometry.
    Lyon TD; Cunningham C; Halls DJ; Gibbons J; Keating A; Fell GS
    Ann Clin Biochem; 1995 Mar; 32 ( Pt 2)():160-6. PubMed ID: 7785943
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of aluminium in serum and urine for the biomonitoring of occupational exposure.
    Valkonen S; Aitio A
    Sci Total Environ; 1997 Jun; 199(1-2):103-10. PubMed ID: 9200852
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry.
    Parkinson IS; Ward MK; Kerr DN
    Clin Chim Acta; 1982 Oct; 125(2):125-33. PubMed ID: 7139954
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An electrothermal atomic absorption method for aluminum analysis in plasma: identification of sources of contamination in blood sampling procedures.
    Kostyniak PJ
    J Anal Toxicol; 1983; 7(1):20-3. PubMed ID: 6834793
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aluminium in water for preparation of dialysate and in serum of dialysed patients.
    Blanusa M; Prester L; Crnogorac M; Puretić Z; Bubić-Filipi L; Dadić Z
    Arh Hig Rada Toksikol; 1997 Jun; 48(2):197-204. PubMed ID: 9434431
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Determination of aluminum in the blood: extra-analytical factors].
    Minoia C; Tempini G; Salvadeo A; Vitali MT; Micoli G
    G Ital Med Lav; 1984; 6(5-6):239-49. PubMed ID: 6545215
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selenium measurement in human plasma with Zeeman effect electrothermal atomic absorption spectrometry: sample stability and calibration method.
    Sabé R; Rubio R; García-Beltrán L
    J Trace Elem Med Biol; 2003; 17(2):73-7. PubMed ID: 14531634
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved electrothermal determination of aluminum in serum by atomic absorption spectroscopy.
    Alderman FR; Gitelman HJ
    Clin Chem; 1980 Feb; 26(2):258-60. PubMed ID: 7353272
    [TBL] [Abstract][Full Text] [Related]  

  • 14. French external quality assessment schemes for lead in blood and aluminum in plasma and dialysis water.
    Guillard O; Piriou A; Pineau A
    Ann Ist Super Sanita; 1996; 32(2):241-5. PubMed ID: 8913042
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Guildford trace elements external quality assessment scheme.
    Taylor A; Briggs RJ
    Ann Ist Super Sanita; 1996; 32(2):253-9. PubMed ID: 8913044
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrophotometry for the determination of trace elements in blood and urine from non occupationally exposed populations.
    White MA
    J Trace Elem Med Biol; 1999 Jul; 13(1-2):93-101. PubMed ID: 10445225
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of aluminium in human serum by means of flameless atomic absorption technique.
    Brasche M; Fuchs C
    Z Klin Chem Klin Biochem; 1974 May; 12(5):219. PubMed ID: 4440098
    [No Abstract]   [Full Text] [Related]  

  • 18. [Determination of aluminium in blood-serum by inductively coupled plasma (ICP)-spectroscopy (author's transl)].
    Schramel P; Wolf A; Klose BJ
    J Clin Chem Clin Biochem; 1980 Sep; 18(9):591-3. PubMed ID: 7441187
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of determination of lead (Pb) in blood by electrothermal atomic absorption spectrometry (ETAAS) on the basis of interlaboratory comparison data.
    Izquierdo Alvarez S; Calvo Ruata ML; González López JM; de Jalón Comet AG; Escanero Marcén JF
    J Trace Elem Med Biol; 2007; 21 Suppl 1():26-8. PubMed ID: 18039491
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Serum aluminium measurement by DC plasma emission spectrometry.
    Roberts NB; Williams P
    Ann Clin Biochem; 1988 Mar; 25 ( Pt 2)():169-75. PubMed ID: 3382147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.