These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 4057292)

  • 21. The influence of different electrode temperatures on the recorded transcutaneous Po2 level.
    Löfgren O; Jacobson L
    Pediatrics; 1979 Dec; 64(6):892-7. PubMed ID: 514717
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transcutaneous PO2 monitoring during pediatric surgery.
    Venus B; Patel KC; Pratap KS; Konchigeri H; Vidyasagar D
    Crit Care Med; 1981 Oct; 9(10):714-6. PubMed ID: 7285609
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A prospective randomized trial comparing oxygen delivery versus transcutaneous pressure of oxygen values as resuscitative goals.
    Yu M; Chapital A; Ho HC; Wang J; Takanishi D
    Shock; 2007 Jun; 27(6):615-22. PubMed ID: 17505300
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Transcutaneous measurement of pO2.(author's transl)].
    Dautzenberg B; Carter H; Sors C
    Rev Fr Mal Respir; 1981; 9(4):327-35. PubMed ID: 7302351
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Multicomponent noninvasive physiologic monitoring of circulatory function.
    Shoemaker WC; Appel PL; Kram HB; Nathan RC; Thompson JL
    Crit Care Med; 1988 May; 16(5):482-90. PubMed ID: 2966035
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients.
    Martin M; Brown C; Bayard D; Demetriades D; Salim A; Gertz R; Azarow K; Wo CC; Shoemaker W
    J Pediatr Surg; 2005 Dec; 40(12):1957-63. PubMed ID: 16338328
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Interpretation of the tcPO2 curve in adult patients in an intensive care unit.
    Rooth G; Hedstrand U; Ogren C
    Birth Defects Orig Artic Ser; 1979; 15(4):557-71. PubMed ID: 534740
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcutaneous PO2 monitoring during sodium nitroprusside infusion.
    Tremper KK; Waxman KS; Applebaum RA; Konchigeri HN; Zaccari J; Hufstedler SM; Farnum M
    Crit Care Med; 1985 Feb; 13(2):65-7. PubMed ID: 3967507
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of experimental head compression on transcutaneous scalp PO2 in fetal lambs.
    Wallenburg HC; Verhoeff A; Jansen TC; Van der Wiel AR
    Obstet Gynecol; 1984 Aug; 64(2):239-43. PubMed ID: 6429593
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of transcutaneous oxygen tension with arterial oxygen tension in newborn infants with severe respiratory illnesses.
    le Souëf PN; Morgan AK; Soutter LP; Reynolds EO; Parker D
    Pediatrics; 1978 Nov; 62(5):692-7. PubMed ID: 724311
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transcutaneous measurement of partial pressure of oxygen and carbon dioxide.
    Franklin ML
    Respir Care Clin N Am; 1995 Sep; 1(1):119-31. PubMed ID: 9390854
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Transcutaneous measurements of pO2 in newborns with RDS (author's transl)].
    Haschke F; Häckel F; Hohenauer L
    Klin Padiatr; 1976 Jan; 188(1):73-81. PubMed ID: 943670
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Continuous transcutaneous oxygen monitoring during respiratory failure, cardiac decompensation, cardiac arrest, and CPR. Transcutaneous oxygen monitoring during arrest and CPR.
    Tremper KK; Waxman K; Bowman R; Shoemaker WC
    Crit Care Med; 1980 Jul; 8(7):377-81. PubMed ID: 7408502
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transcutaneous oxygen measurement during one-lung anaesthesia.
    Salmenperä M; Heinonen J
    Acta Anaesthesiol Scand; 1984 Jun; 28(3):241-4. PubMed ID: 6430006
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Transcutaneous measurement of partial pressure of oxygen in paediatric intensive care (author's transl)].
    Emmrich P; Stechele U; Huch R; Huch A
    Dtsch Med Wochenschr; 1975 Sep; 100(38):1892,1897-901. PubMed ID: 1192952
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The influence of different levels of PEEP on peripheral tissue perfusion measured by subcutaneous and transcutaneous oxygen tension.
    Hartmann M; Rosberg B; Jönsson K
    Intensive Care Med; 1992; 18(8):474-8. PubMed ID: 1289372
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Continuous transcutaneous blood gas monitoring during fiberbronchoscopy].
    Emslander HP; Schlehe H; Reimann HJ; Daum S
    Schweiz Med Wochenschr; 1983 Jan; 113(3):114-6. PubMed ID: 6187066
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Noninvasive monitoring of cardiorespiratory parameters.
    Abraham E
    Emerg Med Clin North Am; 1986 Nov; 4(4):791-807. PubMed ID: 3096689
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Noninvasive hemodynamic monitoring for early warning of adult respiratory distress syndrome in trauma patients.
    Tatevossian RG; Shoemaker WC; Wo CC; Dang AB; Velmahos GC; Demetriades D
    J Crit Care; 2000 Dec; 15(4):151-9. PubMed ID: 11138876
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Assessment of two noninvasive monitors of arterial oxygenation in anesthetized man.
    Knill RL; Clement JL; Kieraszewicz HT; Dodgson BG
    Anesth Analg; 1982 Jul; 61(7):582-6. PubMed ID: 7201256
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.