These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 4058346)

  • 1. Hydrostatic and central venous pressure measurement by the IVAC 560 infusion pump.
    Philip JH; Philip BK
    Med Instrum; 1985; 19(5):232-5. PubMed ID: 4058346
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accurate compartment pressure measurement using the Intervenous Alarm Control (IVAC) Pump. Report of a technique.
    Uppal GS; Smith RC; Sherk HH; Mooar P
    J Orthop Trauma; 1992; 6(1):87-9. PubMed ID: 1556629
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new device for continuous ambulatory central venous pressure measurement.
    Buckey JC; Goble RL; Blomqvist CG
    Med Instrum; 1987 Aug; 21(4):238-43. PubMed ID: 3452746
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of pulmonary artery and central venous pressure waveform measurements via digital and graphic measurement methods.
    Ahrens TS; Schallom L
    Heart Lung; 2001; 30(1):26-38. PubMed ID: 11174365
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of catheter site on the agreement of peripheral and central venous pressure measurements in neurosurgical patients.
    Sahin A; Salman MA; Salman AE; Aypar U
    J Clin Anesth; 2005 Aug; 17(5):348-52. PubMed ID: 16102684
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlation of peripheral venous pressure and central venous pressure in kidney recipients.
    Hadimioglu N; Ertug Z; Yegin A; Sanli S; Gurkan A; Demirbas A
    Transplant Proc; 2006 Mar; 38(2):440-2. PubMed ID: 16549142
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Integrated measurement of central venous pressure in pediatric intensive care medicine].
    Netz H
    Klin Padiatr; 1988; 200(1):64-6. PubMed ID: 3367613
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The clinical role of central venous pressure measurements.
    Magder S; Bafaqeeh F
    J Intensive Care Med; 2007; 22(1):44-51. PubMed ID: 17259568
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of hydrostatic pressure measurement with a disposable dome transducer system.
    Philip JH; Philip BK; Lehr JL
    Med Instrum; 1985; 19(6):273-4. PubMed ID: 4079852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Oesophageal manometry. A comparison of hydraulic and syringe catheter infusion systems using a simple hydrostatic bench model.
    Byrne PJ; Keane FB; Hennessy TP
    Clin Phys Physiol Meas; 1984 Aug; 5(3):185-91. PubMed ID: 6488724
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors?
    Choi SJ; Gwak MS; Ko JS; Kim GS; Kim TH; Ahn H; Kim JA; Yang M; Lee S; Kim M
    Liver Transpl; 2007 Oct; 13(10):1414-21. PubMed ID: 17902127
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of peripheral and central venous pressure in awake dogs and cats.
    Chow RS; Kass PH; Haskins SC
    Am J Vet Res; 2006 Dec; 67(12):1987-91. PubMed ID: 17144798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Peripheral venous pressure as a predictor of central venous pressure during orthotopic liver transplantation.
    Hoftman N; Braunfeld M; Hoftman G; Mahajan A
    J Clin Anesth; 2006 Jun; 18(4):251-5. PubMed ID: 16797425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the IVAC 560 volumetric pump. A clinical and laboratory study.
    Hutchinson A; Yeoman PM; Byrne AJ
    Anaesthesia; 1985 Oct; 40(10):996-9. PubMed ID: 4061804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Artifactually elevated basal uterine tonus resulting from measurement of hydrostatic pressure by transducer-tipped intrauterine catheters.
    Ross MG; Walton J
    J Perinatol; 1994; 14(5):408-10. PubMed ID: 7830158
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental evaluation of central venous pressure monitoring in the dog.
    Oakley RE; Olivier B; Eyster GE; Hauptman JG
    J Am Anim Hosp Assoc; 1997; 33(1):77-82. PubMed ID: 8974031
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correlation between centrally versus peripherally transduced venous pressure in prone patients undergoing posterior spine surgery.
    Memtsoudis SG; Jules-Elysse K; Girardi FP; Buschiazzo V; Maalouf D; Sama AA; Urban MK
    Spine (Phila Pa 1976); 2008 Aug; 33(18):E643-7. PubMed ID: 18708916
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A technique for central venous pressure measurement in normal horses.
    Wilsterman S; Hackett ES; Rao S; Hackett TB
    J Vet Emerg Crit Care (San Antonio); 2009 Jun; 19(3):241-6. PubMed ID: 19691508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Baseline compartment pressure measurements in isolated lower extremity fractures without clinical compartment syndrome.
    Prayson MJ; Chen JL; Hampers D; Vogt M; Fenwick J; Meredick R
    J Trauma; 2006 May; 60(5):1037-40. PubMed ID: 16688067
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlation of peripheral venous pressure and central venous pressure in surgical patients.
    Amar D; Melendez JA; Zhang H; Dobres C; Leung DH; Padilla RE
    J Cardiothorac Vasc Anesth; 2001 Feb; 15(1):40-3. PubMed ID: 11254838
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.