95 related articles for article (PubMed ID: 4058818)
1. Continuous subcutaneous insulin therapy during early pregnancy.
Kitzmiller JL; Younger MD; Hare JW; Phillippe M; Vignati L; Fargnoli B; Grause A
Obstet Gynecol; 1985 Nov; 66(5):606-11. PubMed ID: 4058818
[TBL] [Abstract][Full Text] [Related]
2. Glycemic control in pregnant diabetic women using a continuous subcutaneous insulin infusion pump.
Cohen AW; Liston RM; Mennuti MT; Gabbe SG
J Reprod Med; 1982 Oct; 27(10):651-4. PubMed ID: 7175835
[TBL] [Abstract][Full Text] [Related]
3. [Intensified insulin therapy and insulin micro-pumps during pregnancy].
Galuppi V
Minerva Endocrinol; 1994 Jun; 19(2):79-83. PubMed ID: 7968932
[TBL] [Abstract][Full Text] [Related]
4. Intrapartum management of insulin-dependent diabetes mellitus (IDDM) gestants. A comparative study of constant intravenous insulin infusion and continuous subcutaneous insulin infusion pump (CSIIP).
Feldberg D; Dicker D; Samuel N; Peleg D; Karp M; Goldman JA
Acta Obstet Gynecol Scand; 1988; 67(4):333-8. PubMed ID: 3051881
[TBL] [Abstract][Full Text] [Related]
5. Safety of various methods of intensive insulin therapy in hospital condition assessed by hypoglycaemic episodes detected with the use of continuous glucose monitoring system.
Mozdzan M; Ruxer J; Loba J; Siejka A; Markuszewski L
Adv Med Sci; 2006; 51():133-6. PubMed ID: 17357293
[TBL] [Abstract][Full Text] [Related]
6. New concepts and applications in the use of the insulin pump during pregnancy.
Gabbe SG
J Matern Fetal Med; 2000; 9(1):42-5. PubMed ID: 10757434
[TBL] [Abstract][Full Text] [Related]
7. [Intensified insulin therapy by multiple injections or by pump].
Pernet A
Schweiz Med Wochenschr; 1986 Jan; 116(3):77-82. PubMed ID: 3511525
[TBL] [Abstract][Full Text] [Related]
8. Analysis of outcome of pregnancy in type 1 diabetics treated with insulin pump or conventional insulin therapy.
Lapolla A; Dalfrà MG; Masin M; Bruttomesso D; Piva I; Crepaldi C; Tortul C; Dalla Barba B; Fedele D
Acta Diabetol; 2003 Sep; 40(3):143-9. PubMed ID: 14605971
[TBL] [Abstract][Full Text] [Related]
9. Treatment of diabetes mellitus using an external insulin pump in clinical practice.
Jeandidier N; Riveline JP; Tubiana-Rufi N; Vambergue A; Catargi B; Melki V; Charpentier G; Guerci B
Diabetes Metab; 2008 Sep; 34(4 Pt 2):425-38. PubMed ID: 18951117
[TBL] [Abstract][Full Text] [Related]
10. [Diabetes and pregnancy: our experience with the insulin pump].
Lizan G; Lucas P; Muller G
Rev Fr Gynecol Obstet; 1985 Jun; 80(6 Pt 2):451-7. PubMed ID: 4081500
[TBL] [Abstract][Full Text] [Related]
11. Outcome of pregnancy in women with type 1 diabetes intensively treated with continuous subcutaneous insulin infusion or conventional therapy. A case-control study.
Giménez M; Conget I; Nicolau J; Pericot A; Levy I
Acta Diabetol; 2007 Mar; 44(1):34-7. PubMed ID: 17357884
[TBL] [Abstract][Full Text] [Related]
12. [Comparison of intensified traditional insulin therapy and micropump therapy in pregnant women with type 1 diabetes mellitus].
Botta RM; Sinagra D; Angelico MC; Bompiani GD
Minerva Med; 1986 Apr; 77(17):657-61. PubMed ID: 3520389
[TBL] [Abstract][Full Text] [Related]
13. Effect of a local heating device on insulin and glucose pharmacokinetic profiles in an open-label, randomized, two-period, one-way crossover study in patients with type 1 diabetes using continuous subcutaneous insulin infusion.
Raz I; Weiss R; Yegorchikov Y; Bitton G; Nagar R; Pesach B
Clin Ther; 2009 May; 31(5):980-7. PubMed ID: 19539098
[TBL] [Abstract][Full Text] [Related]
14. Feasibility and safety of insulin pump therapy in children aged 2 to 7 years with type 1 diabetes: a retrospective study.
Berhe T; Postellon D; Wilson B; Stone R
Pediatrics; 2006 Jun; 117(6):2132-7. PubMed ID: 16740857
[TBL] [Abstract][Full Text] [Related]
15. Use of glucose-controlled insulin infusion system for improvement of subcutaneous insulin regimen.
Irsigler K; Kritz H; Kaspar L; Brändle J; Franetzki M
Horm Metab Res Suppl; 1979; (8):134-40. PubMed ID: 395070
[TBL] [Abstract][Full Text] [Related]
16. Postprandial insulin profiles with implantable pump therapy may explain decreased frequency of severe hypoglycemia, compared with intensive subcutaneous regimens, in insulin-dependent diabetes mellitus patients.
Nathan DM; Dunn FL; Bruch J; McKitrick C; Larkin M; Haggan C; Lavin-Tompkins J; Norman D; Rogers D; Simon D
Am J Med; 1996 Apr; 100(4):412-7. PubMed ID: 8610727
[TBL] [Abstract][Full Text] [Related]
17. Benefits of a bolus calculator in pre- and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII).
Shashaj B; Busetto E; Sulli N
Diabet Med; 2008 Sep; 25(9):1036-42. PubMed ID: 18937673
[TBL] [Abstract][Full Text] [Related]
18. [Ambulatory treatment of diabetes in children by continuous subcutaneous infusion of insulin using a portable pump].
Bougnères PF; Landier F; Lemmel C; Golse B; Chaussain JL
Arch Fr Pediatr; 1984 Jan; 41(1):27-33. PubMed ID: 6721650
[TBL] [Abstract][Full Text] [Related]
19. Efficacy of subcutaneous insulin lispro versus continuous intravenous regular insulin for the treatment of patients with diabetic ketoacidosis.
Umpierrez GE; Latif K; Stoever J; Cuervo R; Park L; Freire AX; E Kitabchi A
Am J Med; 2004 Sep; 117(5):291-6. PubMed ID: 15336577
[TBL] [Abstract][Full Text] [Related]
20. New strategies for glucose control in patients with type 1 and type 2 diabetes mellitus in pregnancy.
Gabbe SG; Carpenter LB; Garrison EA
Clin Obstet Gynecol; 2007 Dec; 50(4):1014-24. PubMed ID: 17982345
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]