These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Kinetic study on the dimer-tetramer interconversion of phosphorylase b by a stopped-flow X-ray scattering method. Wang ZX; Tsuruta H; Honda Y; Tachi-iri Y; Wakabayashi K; Amemiya Y; Kihara H Biophys Chem; 1989 May; 33(2):153-60. PubMed ID: 2502199 [TBL] [Abstract][Full Text] [Related]
3. Stopped-flow solution scattering using synchrotron radiation: apparatus, data collection and data analysis. Fowler AG; Foote AM; Moody MF; Vachette P; Provencher SW; Gabriel A; Bordas J; Koch MH J Biochem Biophys Methods; 1983 Jul; 7(4):317-29. PubMed ID: 6619508 [TBL] [Abstract][Full Text] [Related]
4. Test reactions for a stopped-flow apparatus. Reduction of 2,6-dichlorophenolindophenol and potassium ferricyanide by L-ascorbic acid. Tonomura B; Nakatani H; Ohnishi M; Yamaguchi-Ito J; Hiromi K Anal Biochem; 1978 Feb; 84(2):370-83. PubMed ID: 626384 [No Abstract] [Full Text] [Related]
5. Kinetic determination of ascorbic acid by the 2,6-dichlorophenolindophenol reaction with a stopped-flow technique. Karayannis MI Anal Chim Acta; 1975 May; 76(1):121-30. PubMed ID: 1147272 [No Abstract] [Full Text] [Related]
6. A rapid sensitive method for the determination of ascorbic acid in the excess of 2,6-dichlorophenolindophenol using a stopped-flow apparatus. Hiromi K; Kuwamoto C; Ohnishi M Anal Biochem; 1980 Jan; 101(2):421-6. PubMed ID: 7362036 [No Abstract] [Full Text] [Related]
11. Kinetic refolding of beta-lactoglobulin. Studies by synchrotron X-ray scattering, and circular dichroism, absorption and fluorescence spectroscopy. Arai M; Ikura T; Semisotnov GV; Kihara H; Amemiya Y; Kuwajima K J Mol Biol; 1998 Jan; 275(1):149-62. PubMed ID: 9451446 [TBL] [Abstract][Full Text] [Related]
12. Dissociation and auto-oxidation of hemerythrin induced by SH-modification: a kinetic study. Fuseya M; Ichimura K; Yamamura T; Tachi'iri Y; Satake K; Amemiya Y; Kihara H J Biochem; 1989 Feb; 105(2):293-8. PubMed ID: 2566598 [TBL] [Abstract][Full Text] [Related]
13. [Wide-angle x-ray scattering comparison of the structure of crystalline cytochrome c and cytochrome c in solution]. Timchenko AA; Denesiuk AI; Fedorov BA Biofizika; 1981; 26(1):32-6. PubMed ID: 6261840 [TBL] [Abstract][Full Text] [Related]
14. Isotope experiments on the 2, 6-dichlorophenolindophenol-mediated oxidation of ascorbic acid by illuminated chloroplasts. HABERMANN HM; VERNON LP Arch Biochem Biophys; 1958 Aug; 76(2):424-9. PubMed ID: 13572027 [No Abstract] [Full Text] [Related]
15. Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events. Liaparinos PF; Kandarakis IS Med Phys; 2011 Jul; 38(7):4440-50. PubMed ID: 21859045 [TBL] [Abstract][Full Text] [Related]
16. Authentication of vegetable oils by confocal X-ray scattering analysis with coherent/incoherent scattered X-rays. Li F; Liu Z; Sun T Food Chem; 2016 Nov; 210():435-41. PubMed ID: 27211668 [TBL] [Abstract][Full Text] [Related]
17. Assessment of the relative performance of a confined impinging jets mixer and a multi-inlet vortex mixer for curcumin nanoparticle production. Chow SF; Sun CC; Chow AH Eur J Pharm Biopharm; 2014 Oct; 88(2):462-71. PubMed ID: 25016977 [TBL] [Abstract][Full Text] [Related]
18. A simple mechanical mixer for small viscous lipid-containing samples. Cheng A; Hummel B; Qiu H; Caffrey M Chem Phys Lipids; 1998 Sep; 95(1):11-21. PubMed ID: 9807807 [TBL] [Abstract][Full Text] [Related]
19. [Photometric method for analysis of ascorbic acid based on oxidation of leuko-2,6-dichlorophenolindophenol]. LAPIN LN; VLADIMIROV GE Biokhimiia; 1945; 10(1):14-24. PubMed ID: 20999511 [No Abstract] [Full Text] [Related]