BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 4071459)

  • 1. Evaluation of Biox IIA ear oximeter.
    Tweeddale PM; Douglas NJ
    Thorax; 1985 Nov; 40(11):825-7. PubMed ID: 4071459
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The accuracy and response characteristics of a simplified ear oximeter.
    Chapman KR; D'Urzo A; Rebuck AS
    Chest; 1983 Jun; 83(6):860-4. PubMed ID: 6851688
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ear oximetry during combined hypoxia and exercise.
    Smyth RJ; D'Urzo AD; Slutsky AS; Galko BM; Rebuck AS
    J Appl Physiol (1985); 1986 Feb; 60(2):716-9. PubMed ID: 3949671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the Ohmeda 3700 pulse oximeter.
    Warley AR; Mitchell JH; Stradling JR
    Thorax; 1987 Nov; 42(11):892-6. PubMed ID: 3424271
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous in vivo measurement of arterial oxygen saturation by oximetry.
    Flick MR; Block AJ
    Heart Lung; 1977; 6(6):990-3. PubMed ID: 244328
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Transesophageal arterial oxygen saturation monitoring: an experimental study].
    Zhu ZQ; Wei W; Yang ZB; Liu AJ; Liu J
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2005 Jan; 36(1):124-6. PubMed ID: 15702800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calibration of a new ear oximeter in humans during exposure to centrifugation.
    Besch EL; Baumgardner FW; Burton RR; Gillingham KK; McPherson RF; Leverett SD
    J Appl Physiol Respir Environ Exerc Physiol; 1978 Mar; 44(3):483-7. PubMed ID: 632190
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia.
    Zeballos RJ; Weisman IM
    Am Rev Respir Dis; 1991 Dec; 144(6):1240-4. PubMed ID: 1741533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The accuracy of the Hewlett-Packard 47201A ear oximeter below 50% saturation.
    Stradling JR
    Bull Eur Physiopathol Respir; 1982; 18(5):791-4. PubMed ID: 6927531
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ear oximetry during progressive hypoxia.
    Gislason T; Sandhagen B; Daskalopouloul E
    Ups J Med Sci; 1988; 93(1):45-51. PubMed ID: 3376352
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reliability of six pulse oximeters in chronic obstructive pulmonary disease.
    Hannhart B; Michalski H; Delorme N; Chapparo G; Polu JM
    Chest; 1991 Apr; 99(4):842-6. PubMed ID: 2009785
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100.
    West P; George CF; Kryger MH
    Sleep; 1987 Jun; 10(3):263-71. PubMed ID: 3629089
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation.
    Saunders NA; Powles AC; Rebuck AS
    Am Rev Respir Dis; 1976 Jun; 113(6):745-9. PubMed ID: 937815
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.
    Ries AL; Farrow JT; Clausen JL
    Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulse oximetry in horses.
    Whitehair KJ; Watney GC; Leith DE; Debowes RM
    Vet Surg; 1990; 19(3):243-8. PubMed ID: 2349781
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of accuracy of pulse oximetry in dogs.
    Jacobson JD; Miller MW; Matthews NS; Hartsfield SM; Knauer KW
    Am J Vet Res; 1992 Apr; 53(4):537-40. PubMed ID: 1586024
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
    Giguère S; Sanchez LC; Shih A
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):529-35. PubMed ID: 25212699
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.