These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 4071598)

  • 21. Lack of clinical significance of "enzyme-only" red cell alloantibodies.
    Issitt PD; Combs MR; Bredehoeft SJ; Campbell ML; Heimer M; Joyner L; Lorentsen L; Remley C; Bullock S; Bumgarner J
    Transfusion; 1993 Apr; 33(4):284-93. PubMed ID: 8480348
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of delayed centrifugation or reading on the detection of ABO incompatibility by the immediate-spin crossmatch.
    Shulman IA; Calderón C
    Transfusion; 1991; 31(3):197-200. PubMed ID: 2003320
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Possible insensitivity of the polybrene antibody screen to detect anti-Jka.
    Liu F; Liu J
    Ann Clin Lab Sci; 2006; 36(1):101-2. PubMed ID: 16501244
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Pretransfusion blood group serology. Limited value of the antiglobulin phase of the crossmatch when a careful screening test for unexpected antibodies is performed.
    Heistø H
    Transfusion; 1979; 19(6):761-3. PubMed ID: 118557
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Compatibility testing without a centrifuge: the slide Polybrene method.
    Lin M
    Transfusion; 2004 Mar; 44(3):410-3. PubMed ID: 14996200
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Assessment and value of the polybrene microplate test for study and identification of irregular anti-erythrocyte antibodies].
    Guignier F; Domy M; Angue M; Richaud P; Chatelain P
    Rev Fr Transfus Immunohematol; 1986; 29(5):377-89. PubMed ID: 3576046
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The risk of an overt hemolytic transfusion reaction following the use of an immediate spin crossmatch.
    Shulman IA
    Arch Pathol Lab Med; 1990 Apr; 114(4):412-4. PubMed ID: 2322101
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Evaluation of the polyethyleneglycol antiglobulin test in the detection and identification of erythrocyte antibodies].
    Jiménez Marco MT; Hernández Maraver D; Rodríguez de la Rua A; de la Cámara Mendizábal C; Canales Albendea M; Jiménez Yuste V; Hernández Navarro F
    Sangre (Barc); 1998 Feb; 43(1):21-4. PubMed ID: 9577178
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Manual polybrene test versus saline test as a means of detecting alloantibodies against red cells in the pretransfusion examination].
    de Chirinos SM; Lichtiger B
    Sangre (Barc); 1991 Feb; 36(1):43-6. PubMed ID: 1853273
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electronic crossmatching.
    Arslan O
    Transfus Med Rev; 2006 Jan; 20(1):75-9. PubMed ID: 16373190
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Incompatible crossmatch following nonreactive antibody detection test. Frequency and cause.
    Mintz PD; Haines AL; Sullivan MF
    Transfusion; 1982; 22(2):107-10. PubMed ID: 7071913
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Pathology consultation on electronic crossmatch.
    Mazepa MA; Raval JS; Park YA;
    Am J Clin Pathol; 2014 May; 141(5):618-24. PubMed ID: 24713731
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Low ionic polybrene (LIP) test for extended blood grouping].
    Nakajima H; Murata M
    Nihon Hoigaku Zasshi; 1984 Apr; 38(2):163-9. PubMed ID: 6434772
    [No Abstract]   [Full Text] [Related]  

  • 34. Safety and cost-containment data that advocate abbreviated pretransfusion testing.
    Cordle DG; Strauss RG; Snyder EL; Floss AM
    Am J Clin Pathol; 1990 Oct; 94(4):428-31. PubMed ID: 2220670
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The computer crossmatch: a safe alternative to the serological crossmatch.
    Chapman JF; Milkins C; Voak D
    Transfus Med; 2000 Dec; 10(4):251-6. PubMed ID: 11123808
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A hemolytic reaction implicating Sda antibody missed by immediate spin crossmatch.
    Reznicek MJ; Cordle DG; Strauss RG
    Vox Sang; 1992; 62(3):173-5. PubMed ID: 1609519
    [TBL] [Abstract][Full Text] [Related]  

  • 37. 2-Mercaptoethanol (2-ME)-based IATs or Polybrene method mitigates the interference of daratumumab on blood compatibility tests.
    Zhou Y; Chen L; Jiang T; Fan L; Lei H; Wang Y; Heililahong H; Mi J; Du D; Miao T; Xia R; Wang X; Xiang D; Cai X; Tang X
    Hematology; 2021 Dec; 26(1):365-370. PubMed ID: 33971806
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Experience with a cost-effective crossmatch protocol.
    Shulman IA; Nelson JM; Kent DR; Jacobs VL; Nakayama RK; Malone SA
    JAMA; 1985 Jul; 254(1):93-5. PubMed ID: 3999355
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The sensitivity and specificity of the immediate-spin crossmatch.
    Meyer EA; Shulman IA
    Transfusion; 1989 Feb; 29(2):99-102. PubMed ID: 2919433
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Experience with the routine use of an abbreviated crossmatch.
    Shulman IA; Nelson JM; Saxena S; Thompson JC; Okamoto M; Kent DR; Nakayama RK
    Am J Clin Pathol; 1984 Aug; 82(2):178-81. PubMed ID: 6465079
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.