  • 1. Comparison of a chromogenic prothrombin time with clotting prothrombin time in the assessment of clinical coagulation deficiencies.
    Francis CW; Malone JE; Marder VJ
    Am J Clin Pathol; 1985 Dec; 84(6):724-9. PubMed ID: 4072967
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A clinical evaluation of automated chromogenic tests as substitutes for conventional prothrombin time and activated partial thromboplastin time tests.
    Duncan A; Bowie EJ; Owen CA; Fass DN
    Clin Chem; 1985 Jun; 31(6):853-5. PubMed ID: 3995763
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of Actin FS and Actin FSL sensitivity to specific clotting factor deficiencies.
    Lawrie AS; Kitchen S; Purdy G; Mackie IJ; Preston FE; Machin SJ
    Clin Lab Haematol; 1998 Jun; 20(3):179-86. PubMed ID: 9681235
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of a centrifugal analyzer for a chromogenic prothrombin time, a chromogenic activated partial thromboplastin time and a kinetic fibrinogen assay in a routine hospital laboratory.
    de Metz M; van Wersch JW
    Haemostasis; 1987; 17(5):254-9. PubMed ID: 3666583
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Paradoxic effect of multiple mild coagulation factor deficiencies on the prothrombin time and activated partial thromboplastin time.
    Burns ER; Goldberg SN; Wenz B
    Am J Clin Pathol; 1993 Aug; 100(2):94-8. PubMed ID: 8356955
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multicenter evaluation of a chromogenic substrate method for photometric determination of prothrombin time.
    Dati F; Barthels M; Conard J; Flückiger J; Girolami A; Hänseler E; Huber J; Keller F; Kolde HJ; Müller-Berghaus G
    Thromb Haemost; 1987 Oct; 58(3):856-65. PubMed ID: 3433249
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.
    Kitchen S; Woolley A
    Blood Coagul Fibrinolysis; 2013 Jan; 24(1):28-34. PubMed ID: 23249565
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mixing Studies in Patients With Prolonged Activated Partial Thromboplastin Time or Prothrombin Time.
    Benzon HT; Park M; McCarthy RJ; Kendall MC; Lindholm PF
    Anesth Analg; 2019 Jun; 128(6):1089-1096. PubMed ID: 31094773
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical evaluation of a fully automated chromogenic method for prothrombin time compared with a conventional coagulation method.
    Tripodi A; Mannucci PM
    Clin Chem; 1984 Aug; 30(8):1392-5. PubMed ID: 6744595
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On-site prothrombin time, activated partial thromboplastin time, and platelet count. A comparison between whole blood and laboratory assays with coagulation factor analysis in patients presenting for cardiac surgery.
    Despotis GJ; Santoro SA; Spitznagel E; Kater KM; Barnes P; Cox JL; Lappas DG
    Anesthesiology; 1994 Feb; 80(2):338-51. PubMed ID: 8311316
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recombinant tissue factor as substitute for conventional thromboplastin in the prothrombin time test.
    Tripodi A; Arbini A; Chantarangkul V; Mannucci PM
    Thromb Haemost; 1992 Jan; 67(1):42-5. PubMed ID: 1615481
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparative multicenter study of a rabbit high-sensitivity thromboplastin and a recombinant thromboplastin with synthetic phospholipids].
    Martínez-Brotóns F; Borrell M; Fontcuberta J; Batlle J; López F; Páramo JA; Ribera C; Rocha E; Vicente V; Zuazu I
    Sangre (Barc); 1994 Aug; 39(4):245-51. PubMed ID: 7985052
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Underestimation of plasma level of factor V coagulant activity and fibrinogen concentration together with prolonged prothrombin time, activated partial thromboplastin time and thrombin time can result from pre-analytical very low calcium level in citrated sample tube.
    d'Audigier C; Delassasseigne C; Robert A; Eschwège V
    Int J Lab Hematol; 2016 Feb; 38(1):50-3. PubMed ID: 26406495
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coagulation Testing in the Core Laboratory.
    Winter WE; Flax SD; Harris NS
    Lab Med; 2017 Nov; 48(4):295-313. PubMed ID: 29126301
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Investigation of coagulation time: PT and APTT].
    Ramakers C; van der Heul C; van Wijk EM
    Ned Tijdschr Geneeskd; 2012; 156(0):A3985. PubMed ID: 22917038
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A single-institution retrospective study of causes of prolonged prothrombin time and activated partial thromboplastin time in the outpatient setting.
    Hazim AZ; Ruan GJ; Khodadadi RB; Slusser JP; Marshall AL; Pruthi RK
    Int J Lab Hematol; 2022 Feb; 44(1):209-215. PubMed ID: 34612006
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prothrombin time sensitivity and specificity to mild clotting factor deficiencies of the extrinsic pathway: evaluation of eight commercial thromboplastins.
    Massignon D; Moulsma M; Bondon P; Debize G; Abidi H; Buttin T; Bon C; Pillonchery G; Coeur P
    Thromb Haemost; 1996 Apr; 75(4):590-4. PubMed ID: 8743184
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of bedside prothrombin time and activated partial thromboplastin time measurement by coagulation analyzer CoaguCheck Plus in various clinical settings.
    Ruzicka K; Kapiotis S; Quehenberger P; Handler S; Hornykewycz S; Michitsch A; Huber K; Clemens D; Susan M; Pabinger I; Eichinger S; Jilma B; Speiser W
    Thromb Res; 1997 Sep; 87(5):431-40. PubMed ID: 9306617
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multicentric evaluation of heparinase on aPTT, thrombin clotting time and a new PT reagent based on recombinant human tissue factor.
    Harenberg J; Reichel T; Malsch R; Hirsh J; Rustagi P
    Blood Coagul Fibrinolysis; 1996 Jun; 7(4):453-8. PubMed ID: 8839997
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chromogenic substrates for activated partial thromboplastin time testing: are they worth using?
    Tripodi A
    Ric Clin Lab; 1989; 19(4):355-8. PubMed ID: 2517351
    [TBL] [Abstract][Full Text] [Related]  