These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 4077439)

  • 41. Scatter compensation in digital chest radiography using Fourier deconvolution.
    Floyd CE; Beatty PT; Ravin CE
    Invest Radiol; 1989 Jan; 24(1):30-3. PubMed ID: 2917820
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Digital beam attenuator technique for compensated chest radiography.
    Hasegawa BH; Naimuddin S; Dobbins JT; Mistretta CA; Peppler WW; Hangiandreou NJ; Cusma JT; McDermott JC; Kudva BV; Melbye KM
    Radiology; 1986 May; 159(2):537-43. PubMed ID: 3961188
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Characterization of scatter in digital mammography from physical measurements.
    Leon SM; Brateman LF; Wagner LK
    Med Phys; 2014 Jun; 41(6):061901. PubMed ID: 24877812
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A phantom approach to find the optimal technical parameters for plain chest radiography.
    Vassileva J
    Br J Radiol; 2004 Aug; 77(920):648-53. PubMed ID: 15326041
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Iterative scatter correction for grid-less skeletal radiography allows improved image quality equal to an antiscatter grid in adjunct with dose reduction: a visual grading study of 20 body donors.
    Lisson CG; Lisson CS; Kleiner S; Regier M; Beer M; Schmidt SA
    Acta Radiol; 2019 Jun; 60(6):735-741. PubMed ID: 30149748
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Characterizing Scatter Correction Software of 5 Mobile Radiography Units: An Anthropomorphic Phantom Study.
    Gossye T; Buytaert D; Smeets PV; Morbée L; Vereecke E; Achten E; Bacher K
    Invest Radiol; 2022 Jul; 57(7):444-452. PubMed ID: 35085123
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A technique of scatter-glare correction using a digital filtration.
    Honda M; Ema T; Kikuchi K; Ohe M; Komatsu K
    Med Phys; 1993; 20(1):59-69. PubMed ID: 8455514
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Pediatric air-gap chest digital imaging: an experimental study.
    Kuhns LR; Kottamasu SR
    Pediatr Radiol; 1995 Nov; 25 Suppl 1():S199-201. PubMed ID: 8577526
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Monte Carlo study of grid performance in diagnostic radiology: factors which affect the selection of tube potential and grid ratio.
    Sandborg M; Dance DR; Carlsson GA; Persliden J
    Br J Radiol; 1993 Dec; 66(792):1164-76. PubMed ID: 8293262
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Chest radiography: depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography.
    Woodard PK; Slone RM; Gierada DS; Reiker GG; Pilgram TK; Jost RG
    Radiology; 1997 Apr; 203(1):197-201. PubMed ID: 9122392
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Grids or air gaps for scatter reduction in digital radiography: a model calculation.
    Neitzel U
    Med Phys; 1992; 19(2):475-81. PubMed ID: 1584148
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.
    Patel T; Peppard H; Williams MB
    Med Phys; 2016 Apr; 43(4):1720. PubMed ID: 27036570
    [TBL] [Abstract][Full Text] [Related]  

  • 53. New method for the experimental evaluation of x-ray grids.
    Dick CE; Motz JW
    Med Phys; 1978; 5(2):133-40. PubMed ID: 683152
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Scatter radiation in cephalometric radiography: the effects of grid and collimation.
    Tsuji Y; Araki K; Endo A; Okano T
    Dentomaxillofac Radiol; 2006 Jul; 35(4):278-82. PubMed ID: 16798926
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Usefulness of Combining Post-processing Scatter Correction and an Anti-scatter Grid in Chest Standing Radiography].
    Fujikawa K; Osaki T; Nakagawa H; Kikuchi K; Kiriki M; Wada Y; Miki R; Kotoura N
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2021; 77(6):555-563. PubMed ID: 34148897
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system.
    Shen SZ; Bloomquist AK; Mawdsley GE; Yaffe MJ; Elbakri I
    Med Phys; 2006 Apr; 33(4):1108-15. PubMed ID: 16696488
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The hypertransradiant hemithorax: the importance of lateral decentring, and the explanation for its appearance due to rotation.
    Joseph AE; de Lacey GJ; Bryant TH; Stoker DJ; Ayr G
    Clin Radiol; 1978 Mar; 29(2):125-31. PubMed ID: 639449
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Single-slit digital radiography: some practical considerations.
    Tesic MM; Sones RA; Morgan DR
    AJR Am J Roentgenol; 1984 Apr; 142(4):697-702. PubMed ID: 6367399
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Relative dose efficiencies of antiscatter grids and air gaps in pediatric radiography.
    McDaniel DL; Cohen G; Wagner LK; Robinson LH
    Med Phys; 1984; 11(4):508-12. PubMed ID: 6482846
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.
    Maslowski A; Wang A; Sun M; Wareing T; Davis I; Star-Lack J
    Med Phys; 2018 May; 45(5):1899-1913. PubMed ID: 29509970
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.