These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
139 related articles for article (PubMed ID: 4079861)
1. Investigation of basic imaging properties in digital radiography. 6. MTFs of II-TV digital imaging systems. Fujita H; Doi K; Giger ML Med Phys; 1985; 12(6):713-20. PubMed ID: 4079861 [TBL] [Abstract][Full Text] [Related]
2. A simple method for determining the modulation transfer function in digital radiography. Fujita H; Tsai DY; Itoh T; Doi K; Morishita J; Ueda K; Ohtsuka A IEEE Trans Med Imaging; 1992; 11(1):34-9. PubMed ID: 18218354 [TBL] [Abstract][Full Text] [Related]
3. Resolution properties of a 2048 x 2048 matrix image intensifier-TV based digital radiography system. Ogura T; Fujita H Med Phys; 1994 Mar; 21(3):463-9. PubMed ID: 8208222 [TBL] [Abstract][Full Text] [Related]
4. Improvement of spatial resolution properties of image intensifier-TV digital systems with a multiple-narrow-slit beam imaging technique. Kume Y; Doi K Med Phys; 1988; 15(6):846-52. PubMed ID: 3237141 [TBL] [Abstract][Full Text] [Related]
5. Investigation of basic imaging properties in digital radiography. 12. Effect of matrix configuration on spatial resolution. Fujita H; Giger ML; Doi K Med Phys; 1988; 15(3):384-90. PubMed ID: 3405142 [TBL] [Abstract][Full Text] [Related]
6. Digital x-ray imaging using amorphous selenium: reduction of aliasing. Ji WG; Zhao W; Rowlands JA Med Phys; 1998 Nov; 25(11):2148-62. PubMed ID: 9829239 [TBL] [Abstract][Full Text] [Related]
7. Basic imaging properties of a computed radiographic system with photostimulable phosphors. Fujita H; Ueda K; Morishita J; Fujikawa T; Ohtsuka A; Sai T Med Phys; 1989; 16(1):52-9. PubMed ID: 2921980 [TBL] [Abstract][Full Text] [Related]
8. Investigation of basic imaging properties in digital radiography. I. Modulation transfer function. Giger ML; Doi K Med Phys; 1984; 11(3):287-95. PubMed ID: 6738452 [TBL] [Abstract][Full Text] [Related]
9. Comparison of two methods for accurate measurement of modulation transfer functions of screen-film systems. Morishita J; Doi K; Bollen R; Bunch PC; Hoeschen D; Sirand-rey G; Sukenobu Y Med Phys; 1995 Feb; 22(2):193-200. PubMed ID: 7565350 [TBL] [Abstract][Full Text] [Related]
10. Investigation of basic imaging properties in digital radiography. 11. Multiple slit-beam imaging technique with image intensifier-TV digital system. Kume Y; Doi K Med Phys; 1987; 14(5):736-43. PubMed ID: 3683302 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of an algorithm for the assessment of the MTF using an edge method. Greer PB; van Doorn T Med Phys; 2000 Sep; 27(9):2048-59. PubMed ID: 11011732 [TBL] [Abstract][Full Text] [Related]
12. Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems. Dobbins JT Med Phys; 1995 Feb; 22(2):171-81. PubMed ID: 7565348 [TBL] [Abstract][Full Text] [Related]
13. Investigation of basic imaging properties in digital radiography 10. Structure mottle of II-TV digital imaging systems. Kume Y; Doi K; Ohara K; Giger ML Med Phys; 1986; 13(6):843-9. PubMed ID: 3796481 [TBL] [Abstract][Full Text] [Related]
14. Investigation of basic imaging properties in digital radiography. 5. Characteristic curves of II-TV digital systems. Fujita H; Doi K; Giger ML; Chan HP Med Phys; 1986; 13(1):13-8. PubMed ID: 3951404 [TBL] [Abstract][Full Text] [Related]
15. Measurement of the presampling modulation transfer function of film digitizers using a curve fitting technique. Yin FF; Giger ML; Doi K Med Phys; 1990; 17(6):962-6. PubMed ID: 2280739 [TBL] [Abstract][Full Text] [Related]
16. Investigation of basic imaging properties in digital radiography. 7. Noise Wiener spectra of II-TV digital imaging systems. Giger ML; Doi K; Fujita H Med Phys; 1986; 13(2):131-8. PubMed ID: 3517612 [TBL] [Abstract][Full Text] [Related]
17. Determination of the two-dimensional detective quantum efficiency of a computed radiography system. Båth M; Håkansson M; Månsson LG Med Phys; 2003 Dec; 30(12):3172-82. PubMed ID: 14713084 [TBL] [Abstract][Full Text] [Related]
18. Signal and noise in modulation transfer function determinations using the slit, wire, and edge techniques. Cunningham IA; Reid BK Med Phys; 1992; 19(4):1037-44. PubMed ID: 1518465 [TBL] [Abstract][Full Text] [Related]
19. [Physical imaging properties of a flat panel X-ray detector system]. Yoshida A; Nakamura S; Nishihara S; Kohama C; Takahata A; Fujikawa K Igaku Butsuri; 2002; 22(4):246-54. PubMed ID: 12766270 [TBL] [Abstract][Full Text] [Related]
20. Optical image processing with liquid-crystal display for image intensifier/television systems. Lam KL; Chan HP; Doi K Med Phys; 1988; 15(6):838-45. PubMed ID: 3237140 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]