These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 4084250)

  • 41. A novel approach to electrode signal analysis for glucose determination.
    Zawicki I; Nalecz M; Dudzinska E
    Biomed Biochim Acta; 1989; 48(11-12):879-82. PubMed ID: 2636832
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Platinum black coated microdisk electrodes for the determination of high concentrations of hydrogen peroxide in phosphate buffer solutions.
    Kicela A; Daniele S
    Talanta; 2006 Feb; 68(5):1632-9. PubMed ID: 18970508
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Activity of various endogenous compounds and pharmacologic agents at a glucose-oxidizing platinum electrode.
    Guyton JR; Chang KW; Aisenberg S; Soeldner JS
    Med Instrum; 1975; 9(5):227-32. PubMed ID: 1186534
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Implantable glucose sensor.
    Wilkins E; Wilkins MG
    J Biomed Eng; 1983 Oct; 5(4):309-15. PubMed ID: 6632843
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Sugar electrode sensor for the "artificial pancreas".
    Bessman SP; Schultz RD
    Horm Metab Res; 1972 Nov; 4(6):413-7. PubMed ID: 4655496
    [No Abstract]   [Full Text] [Related]  

  • 46. Measurement of glucose concentration in the presence of coreactants with a platinum electrode.
    Lerner H; Soeldner JS; Colton CK; Giner J
    Diabetes Care; 1982; 5(3):229-37. PubMed ID: 7172990
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A micro carbon electrode for nitric oxide monitoring.
    Yao SJ; Xu W; Wolfson SK
    ASAIO J; 1995; 41(3):M404-9. PubMed ID: 8573834
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Continuous glucose monitor based on an immobilized enzyme electrode detector.
    Updike SJ; Shults MC; Busby M
    J Lab Clin Med; 1979 Apr; 93(4):518-27. PubMed ID: 429857
    [No Abstract]   [Full Text] [Related]  

  • 49. The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma.
    Kerner W; Kiwit M; Linke B; Keck FS; Zier H; Pfeiffer EF
    Biosens Bioelectron; 1993; 8(9-10):473-82. PubMed ID: 8311940
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A glucose electrode using high-stability glucose-oxidase collagen membranes.
    Thévenot DR; Sternberg R; Coulet P
    Diabetes Care; 1982; 5(3):203-6. PubMed ID: 7172984
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Evaluation of a miniature blood glucose sensor.
    Lewandowski JJ; Malchesky PS; Zborowski M; Nosé Y
    ASAIO Trans; 1988; 34(3):255-8. PubMed ID: 3196516
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Monitoring of glucose concentration in subcutaneous tissue with a glucose electrode mounted in a hydroxyapatite skin button].
    Kusano H; Togawa T; Tsuji T; Aoki H; Shin Y; Higashikata M
    Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1986; 20():97-104. PubMed ID: 3506239
    [No Abstract]   [Full Text] [Related]  

  • 53. In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor.
    Poitout V; Moatti D; Velho G; Reach G; Sternberg R; Thévenot DR; Bindra DS; Zhang YN; Wilson GS
    ASAIO Trans; 1991; 37(3):M298-300. PubMed ID: 1751159
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Flexible valinomycin electrodes for on-line determination of intravascular and myocardial K+.
    Hill JL; Gettes LS; Lynch MR; Hebert NC
    Am J Physiol; 1978 Oct; 235(4):H455-9. PubMed ID: 696888
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Continuous extracorporeal monitoring of animal blood using the glucose electrode.
    Layne EC; Schultz RD; Thomas LJ; Slama G; Sayler DF; Bessman SP
    Diabetes; 1976 Feb; 25(2):81-9. PubMed ID: 1248675
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Electrochemical determination of glucose concentration in saline solutions.
    Lewandowski JJ; Weryński A; Weroński EB
    Med Prog Technol; 1979 Nov; 6(4):163-8. PubMed ID: 392297
    [TBL] [Abstract][Full Text] [Related]  

  • 57. In vitro and in vivo testing of an electrocatalytic glucose sensor.
    Drake RF; Mayhan KG; Sarangapani S; Giner J; Picha GJ; Colton CK
    ASAIO Trans; 1990; 36(3):M591-4. PubMed ID: 2252759
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Evaluation of glucose measurement method using multilayer film analytical element, Drichem 1000.
    Chung MY; Doi K; Nishiyama K; Oribe T; Endo H; Baba S
    Kobe J Med Sci; 1987 Apr; 33(2):65-71. PubMed ID: 3613467
    [No Abstract]   [Full Text] [Related]  

  • 59. Continuous in vivo glucose analysis based on immobilized enzyme bonded to derivatized Teflon membrane.
    Shults M; Updike S; Busby M; Sokol L; Garber C
    Trans Am Soc Artif Intern Organs; 1979; 25():66-70. PubMed ID: 524639
    [No Abstract]   [Full Text] [Related]  

  • 60. A thin-film glucose electrode system with compensation for drift.
    Yao SJ; Guvench S; Guvench MG; Chan LT; Ruppel-Kerr R; Lien M; Wolfson SK
    ASAIO Trans; 1989; 35(3):742-4. PubMed ID: 2597579
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.