These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 410095)

  • 1. Assay of gentamicin concentrations in serum specimens by microbiological and radioenzymatic methods.
    Dornbusch K
    Scand J Infect Dis; 1977; 9(3):227-31. PubMed ID: 410095
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The acetyltransferase enzyme method for the assay of serum gentamicon concentrations and a comparison with other methods.
    Broughall JM; Reeves DS
    J Clin Pathol; 1975 Feb; 28(2):140-5. PubMed ID: 805161
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin.
    Delaney CJ; Opheim KE; Smith AL; Plorde JJ
    Antimicrob Agents Chemother; 1982 Jan; 21(1):19-25. PubMed ID: 7044297
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Serum gentamicin assays of 100 clinical serum samples by a rapid 40 degrees C. Klebsiella method compared with overnight plate diffusion and acetyltransferase assays.
    Shanson DC; Hince C
    J Clin Pathol; 1977 Jun; 30(6):521-5. PubMed ID: 874108
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A rapid semiautomated bioassay of gentamicin based on luciferase assay of bacterial adenosine triphosphate.
    Nilsson L; Höjer H; Anséhn S; Thore A
    Scand J Infect Dis; 1977; 9(3):232-6. PubMed ID: 410096
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Rapid bioassay of gentamicin by bioluminescence (author's transl)].
    Darmon C; Philippon A; Paul G; Nevot P
    Pathol Biol (Paris); 1982 Feb; 30(2):124-8. PubMed ID: 6806765
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Rapid microbiological method of determining the gentamicin, sisomicin and kanamycin concentrations in patients' serum].
    Goncharskaia TIa; Koroleva VG; Umnova LV; Bogomolova NS; Treskina OS
    Antibiotiki; 1981 May; 26(5):367-70. PubMed ID: 6789763
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radioimmunoassay, acetylating radio-enzymatic assay, and microbioassay of gentamicin: a comparative study.
    Stevens P; Young LS; Hewitt WL
    J Lab Clin Med; 1975 Aug; 86(2):349-59. PubMed ID: 1097551
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Photograms for microbiological assays.
    Miller MH; Edberg SC; Daly CC
    J Clin Microbiol; 1980 Mar; 11(3):295-6. PubMed ID: 6769948
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An enzymatic radioassay for gentamicin.
    Case RV; Mezei LM
    Clin Chem; 1978 Dec; 24(12):2145-50. PubMed ID: 719861
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of the homogeneous enzyme immunoassay (EMIT) autocarousel and quantitative single test (QST) systems with the radioenzymatic assay.
    Warren C; Phillips I
    J Antimicrob Chemother; 1986 Feb; 17(2):255-62. PubMed ID: 3516966
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Correlation of bioluminescent assay of gentamicin in serum with agar diffusion assay, latex agglutination inhibition card test, enzyme immunoassay, and fluorescence immunoassay.
    Nilsson L
    J Clin Microbiol; 1984 Sep; 20(3):396-9. PubMed ID: 6436304
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of serum gentamicin assay procedures for a clinical microbiology laboratory.
    Lantz CH; Lawrie DJ; Witebsky FG; MacLowry JD
    J Clin Microbiol; 1980 Oct; 12(4):583-9. PubMed ID: 6775014
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Assessment of aminoglycoside serum concentrations. Comparative study using gentamicin (author's transl)].
    Simmen HP; Rieder H; Bonetti A; Lüthy R
    Dtsch Med Wochenschr; 1981 Jul; 106(29-30):946-50. PubMed ID: 7021119
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The microbiological rapid determination of gentamicin concentrations in the serum].
    Jaschek I; Hitzenberger G; Dingledein E; Wahlig H
    Wien Med Wochenschr; 1978 Apr; 128(8):231-3. PubMed ID: 349895
    [No Abstract]   [Full Text] [Related]  

  • 16. Assay of gentamicin in serum: a comparison of four methods.
    Männistö PT
    Methods Find Exp Clin Pharmacol; 1982; 4(3):167-71. PubMed ID: 6750280
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of radiopharmaceuticals on radioenzymatic assays of aminoglycoside antibiotics: interference by gallium-67 and its elimination.
    Bhattacharya I; Seligsohn R; Lerner SA
    Antimicrob Agents Chemother; 1978 Sep; 14(3):448-53. PubMed ID: 360985
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of serum for gentamicin by radioimmunoassay.
    Griffiths WC; Dextraze P; Diamond I
    Ann Clin Lab Sci; 1977; 7(2):141-5. PubMed ID: 851347
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of enzyme multiplied immunoassay technique for gentamicin assay. Comparison with bioassay].
    Sakata H; Takimoto M; Fujita Y; Kitsutaka T
    Jpn J Antibiot; 1982 May; 35(5):1229-32. PubMed ID: 6752460
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A spectrophotometric assay for gentamicin.
    Williams JW; Langer JS; Northrop DB
    J Antibiot (Tokyo); 1975 Dec; 28(12):982-7. PubMed ID: 1107283
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.